EEWORLDEEWORLDEEWORLD

Part Number

Search

66.9738-200-20

Description
Interconnection Device,
CategoryThe connector    The connector   
File Size381KB,6 Pages
ManufacturerMulti-Contact AG
Environmental Compliance
Download Datasheet Parametric View All

66.9738-200-20 Overview

Interconnection Device,

66.9738-200-20 Parametric

Parameter NameAttribute value
Is it lead-free?Lead free
Is it Rohs certified?conform to
Reach Compliance Codecompliant
Other featuresMULTILAM
Connector typeINTERCONNECTION DEVICE
Base Number Matches1
®
Ø 4 mm-Messleitungen
mit stapelbaren Steckern
Ø 4 mm Test Leads
with Stackable Plugs
Cordons de mesure Ø 4 mm
à reprise arrière
7
LK4-A
33
L
Hoch flexible Messleitung, beidseitig mit stapel-
barem Ø 4 mm-Hohlstecker.
Highly flexible test lead with stackable Ø 4 mm
hollow plugs on both ends.
Cordon de mesure extra-souple, équipé des
deux côtés d'une fiche creuse Ø 4 mm à reprise
arrière.
Längen [cm]
Lead lengths [cm]
Longueurs [cm]
*Farben
*Colours
*Couleurs
Typ
Type
Type
Best.-Nr.
Order No.
N° de Cde
Bemessungsspannung / -strom
Rated voltage / current
Tension / intensité assignée
30 V
AC
~ 60 V
DC
/ 19 A
Leitungsquerschnitt
Lead cross section
Section du câble
LK4-A
28.0053-T*
1,0 mm²
Gp
C D E
F G H
123
4
5
Q
Q
Q
Q
Q
678
9
Q
Q
QL
LK4-B
LK4-B/SIL
33.4
L
Hoch flexible Messleitungen mit PVC- oder Sili-
con-Isolierung, beidseitig mit stapelbarem
Ø 4 mm-Hohlstecker.
Typ
Type
Type
Best.-Nr.
Order No.
N° de Cde
Highly flexible test leads with insulation in PVC
or Silicone with stackable Ø 4 mm hollow plugs
on both ends.
Leitungsquerschnitt
Lead cross section
Section du câble
Cordons de mesure extra-souples à isolation
en PVC ou Silicone, équipés des deux côtés
d'une fiche creuse Ø 4 mm à reprise arrière.
Längen [cm]
Lead lengths [cm]
Longueurs [cm]
*Farben
*Colours
*Couleurs
Bemessungsspannung / -strom
Rated voltage / current
Tension / intensité assignée
30 V
AC
~ 60 V
DC
/ 19 A
30 V
AC
~ 60 V
DC
/ 19 A
LK4-B
LK4-B/SIL
28.0055-T*
28.0056-T*
1,0 mm²
Gp
Gs
C D E
F G H
C D E
F G H
1,0 mm²
123
4
5
Q
Q
Q
Q
Q
9
L
123
4
5
Q
Q
Q
Q
Q
FML SML
60
PVC / SIL
L
Hoch flexible Messleitungen mit PVC- oder Sili-
con-Isolierung, beidseitig mit umspritztem, sta-
pelbarem Ø 4 mm-Lamellenstecker.
Highly flexible test leads with insulation in PVC
or Silicone with moulded stackable Ø 4 mm
Multilam™ plugs on both ends.
Cordons de mesure extra-souples à isolation
en PVC ou Silicone, équipés des deux côtés
d'une fiche à lamelles Ø 4 mm surmoulée à re-
prise arrière.
Längen [cm]
Lead lengths [cm]
Longueurs [cm]
*Farben
*Colours
*Couleurs
Typ
Type
Type
Best.-Nr.
Order No.
N° de Cde
Bemessungsspannung / -strom
Rated voltage / current
Tension / intensité assignée
30 V
AC
~ 60 V
DC
/ 15 A
30 V
AC
~ 60 V
DC
/ 15 A
Leitungsquerschnitt
Lead cross section
Section du câble
FML
SML
64.7289-T*
64.7288-T*
0,75 mm²
Np
Ns
C D F
G H
C D F
G H
0,75 mm²
123
4
5
Q
Q
Q
Q
Q
6
Q
123
4
5
Q
Q
Q
Q
Q
6
Q
50
www.multi-contact.com
10
PVC / SIL
10
PVC
[EETALK]What are the applications of GaN in RF?
When it comes to GaN, what most people are familiar with is GaN fast charging. But in fact, GaN also has great potential in the RF field.Currently, the most common application of GaN in the RF industr...
okhxyyo RF/Wirelessly
Free application: 800MHz RISC-V high-performance domestic chip, Xianji HPM6750EVK2 is coming, OpenHarmony buff
Evaluation kit: HPM6750EVK2 (3 sets in total) Kit source: Pioneer Semiconductor The forum has launched the HPM6750 mini version of this domestic high-performance MCU . At that time, I was amazed by it...
EEWORLD社区 Domestic Chip Exchange
There are some things I don't understand about this circuit that I would like to ask?
IC231 in the circuit is a common op amp, used as a comparator, IC231+ is used to monitor 12V1, IC231- is used to monitor 12VOUT, and a transistor is controlled by the comparator. When 12V1>12VOUT, Q23...
西里古1992 Analog electronics
High frequency transformer air gap
High-frequency transformer air gapThere are two ways to open the air gap: "grinding" and "padding". I use the padding method here. I pad one side first and measure it. The inductance is much smaller, ...
QWE4562009 Analog electronics
I have a question about static electricity.
Washing hands can release static electricity from the body, right? So it stands to reason that urinating should also release static electricity, right? Shouldn't static electricity flow out of the bod...
sky999 Integrated technical exchanges
How to adjust the abnormal power output
The 12V5A and 5V2A power supply designs have a voltage fluctuation of around 10 when unloaded, which is extremely unstable. When the dummy load R11 is changed from 2K to 600 ohms, the voltage is norma...
Aguilera Power technology

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2926  2916  2813  1485  10  59  57  30  1  24 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号