EEWORLDEEWORLDEEWORLD

Part Number

Search

U5335-02000Q-007BS

Description
Peizoresistive Sensor, 0Psi Min, 100Psi Max, 0.1%, 0.5-4.5V, Cylindrical
CategoryThe sensor    Sensor/transducer   
File Size319KB,8 Pages
ManufacturerTE Connectivity
Websitehttp://www.te.com
Environmental Compliance
Download Datasheet Parametric View All

U5335-02000Q-007BS Overview

Peizoresistive Sensor, 0Psi Min, 100Psi Max, 0.1%, 0.5-4.5V, Cylindrical

U5335-02000Q-007BS Parametric

Parameter NameAttribute value
Is it Rohs certified?conform to
MakerTE Connectivity
Reach Compliance Codeunknown
Maximum accuracy(%)0.1%
Other featuresPort Height = 11.4 MM
body height58.6 mm
Body length or diameter24 mm
Maximum working current5 mA
Maximum operating temperature125 °C
Minimum operating temperature-40 °C
Output range0.5-4.5V
Output typeVOLTAGE OUTPUT
Package Shape/FormCYLINDRICAL
port typeM10X1.0MM
Maximum pressure range100 Psi
Minimum pressure range
Pressure sensing modeSEALED
Sensor/Transducer TypePRESSURE SENSOR,PIEZORESISTIVE
Maximum supply voltage30 V
Minimum supply voltage5 V
Termination typeCONNECTOR
Base Number Matches1
U5300
Industrial Pressure Transducer
SPECIFICATIONS
Superior Accuracy and Total Error Band
Instrument Grade and Compact
Variety of Pressure Ports and Electrical Configurations
Optional Stainless Steel Snubber
CE Compliant and Weatherproof
UL Certified
Gage, Sealed, Absolute, Compound
Expedite Configurations Available (10 Days)
FEATURES
Heavy Industrial CE Approval
10 V/m EMI Protection
Reverse Polarity Protection on Input
Short Circuit Protection on Output
±0.1% Accuracy
±0.5% Total Error Band
Compact Outline
-40°C to +125°C Operating Temperature
Weatherproof
The instrument grade U5300
pressure transducers from the UltraStable line
of MEAS, with their modular design, offer maximum flexibility for different
configurations. This latest series features superior accuracy and total error
band for demanding commercial and heavy industrial applications. This
series is suitable for measurement of liquid or gas pressure, even for difficult
media such as contaminated water, steam, and mildly corrosive fluids.
The wetted material is made of 316L stainless steel and the transducer’s
durability is excellent with no O-rings or organics exposed to the pressure
media. The U5300 is weatherproof and exceeds the latest heavy industrial
CE requirements including surge protection. The circuit is protected from
reverse wiring at input and short circuit at output.
This product is geared to the OEM customer for low to mid volumes. MEAS
stands ready to provide a custom design of the U5300 where the volume and
application warrants. Additional configurations not listed are either available
or possible. Please inquire for further information.
APPLICATIONS
Military/Aerospace Test Stands
Automotive Test Stands
Calibration Equipment
High Accuracy Applications
Stationary Motor Fuel Control
High End Industrial Machinery
SENSOR SOLUTIONS
///U5300
07/2018
Page 1
An impedance matching problem of rf amp
[i=s] This post was last edited by learntest on 2019-4-15 12:25 [/i]Where does he get this 26mV? ? 26mV should be the voltage of VE, right? Because re=26mV/ie, but why is ve 1.2v? 81*(26mv/ie)=50 ohms...
learntest Analog electronics
TI official CMD file description (the actual application file is slightly modified based on the official one)
[size=4]There are three CMD files officially provided by TI: 28335_RAM_lnk.cmd, F28335.cmd, DSP2833x_Headers_nonBIOS.cmd[/size] [size=4] [/size] [size=4]When debugging the program, add the 28335_RAM_l...
Aguilera Microcontroller MCU
Nanxin, Qinheng, Zhaoyi, Yatli...many good boards are free to review here!
For those who love boards, it is a happy thing to see a good board for free evaluation. Now, I want to tell you that there are many good board evaluation activities online in the forum recently. Will ...
okhxyyo Domestic Chip Exchange
Accelerate your debugging skills on MCU, platform (ARM/MIPS, etc.), operating system
[align=left][color=rgb(62, 62, 62)]It's not so much about developing embedded software as it is about debugging embedded software. Software is debugged. Unfortunately, it's the most disliked thing for...
月亦雪 Power technology
The circuit of automatic gain adjustment built with AD603 simulates output distortion
[i=s] This post was last edited by paulhyde on 2014-9-15 03:27 [/i] I found a circuit with automatic gain control on the Internet. After simulating it with multisim, the output of the latter stage is ...
秋牧残雪 Electronics Design Contest
nios operation problem
My nios project has been built and compiled successfully, but the following prompt appears when running Using cable "USB-Blaster [USB-0]", device 1, instance 0x00 Pausing target processor: OK Initiali...
manchu FPGA/CPLD

Technical ResourceMore

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1810  2278  1816  240  602  37  46  5  13  18 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号