Data are valid at +25°C, unless otherwise specified.
Parameter
Input
Nominal input voltage
Permanent input
voltage range (Ui)
Extended permanent input
voltage range
Transient input voltage
Start up input voltage
Start up time
Reflected ripple current
Input current in short circuit
mode (Average)
No load input current
Output
Output voltage
Full temperature range
Ui min. to max.
75% load
Ambient temperature : +25°c
Ui nominal, 75% load
Full temperature range
Ui min. to max.
Full temperature range
Ui min. to max.
Nominal
Nominal
Nominal
Nominal
Maximum
Maximum
Maximum
Maximum
Maximum
Maximum
Maximum
Maximum
Maximum
Typical
Typical
Typical
Maximum
Maximum
VDC
VDC
VDC
VDC
%
W
A
A
A
A
mVpp
mVpp
mVpp
%
%
%
µF
µF
3,3
5
12
15
+/- 2
25
6
5
2
1,65
50
100
150
+/- 1
+/- 2,5
83
2.000
470
Conditions
Limit or
typical
Nominal
Min. - Max.
Min. - Max.
Maximum
Minimum
Maximum
Typical
Typical
Maximum
Units
Industrial
Grade
Single Output MGDSI-25
25 - H
20
9-36
/
40/0,1
8,5
30
300
40
60
25 - O
48
18-75
/
80/0,1
17,5
30
300
40
60
Full temperature range
Full temperature range
Full temperature range
(Consult factory)
Full load
(Consult factory)
Full load
Ui nominal within 3 ms
Nominal output
Full load : resistive
Ui nominal, full load at switching
freq. BW = 20MHz
Ui nominal
Short-circuit
Ui nominal
No load
VDC
VDC
VDC
VDC/S
VDC
ms
mApp
mA
mA
3,3
5
12
15
+/- 2
25
6
5
2
1,65
50
100
150
+/- 1
+/- 2,5
83
2.000
470
Set Point accuracy
Output power
Output current *
3,3V output
5V output
12V output
15V output
Ripple output voltage **
3,3V and 5V output
12V output
15V output
Line regulation
Load regulation ***
Efficiency
Maximum admissible
Capacity load
3,3V and 5V output
12V and 15V output
5
Ui nominal
Full load
BW = 20MHz
Ui min. to max.
Full load
Ui nominal
25% to full load
Ui nominal
Full load
Ui nominal
Full load
Per output
Note * : For 9-36 VDC input range modules a derating has to be observed with a power decreasing linearly from 25W at 13 VDC down to 20W at 9 VDC input voltage.
Note ** : The ripple output voltage is the periodic AC component imposed on the output voltage, an aperiodic and random component (noise) has also to be considered. This
noise can be reduced by adding an external capacitor (typically 10nF/rated voltage depending on isolation requirement) connected between the pin Gin and the pin Gout of
the converter. This capacitor should be layed-out as close as possible from the converter.
Note *** : For load regulation characteristics from 0% to full load, please contact factory.
Data are valid at +25°C, unless otherwise specified.
Parameter
Input
Nominal input voltage
Permanent input
voltage range (Ui)
Extended permanent input
voltage range
Transient input voltage
Start up input voltage
Start up time
Reflected ripple current
Input current in short circuit
mode (Average)
No load input current
Output
Output voltage
Set Point accuracy
Output power
Output current *
+/- 5V output
+/- 12V output
+/- 15V output
Ripple output voltage **
5V output
12V output
15V output
Line regulation
Load regulation ***
Cross load output regulation
Efficiency
Maximum admissible
Capacity load
5V output
12V and 15V output
Full temperature range
Ui min. to max.
75% load
Ambient temperature : +25°c
Ui nominal, 75% load
Full temperature range
Ui min. to max.
Full temperature range
Ui min. to max.
Ui nominal
Full load
BW = 20MHz
Ui min. to max.
Full load
Ui nominal
25% to full load
Ui nominal
+ Vout nominal load
- Vout from 25% to full load
Ui nominal
Full load
Ui nominal
Full load
Per output
Nominal
Nominal
Nominal
Maximum
Maximum
Maximum
Maximum
Maximum
Maximum
Maximum
Maximum
Typical
Typical
Typical
Typical
Maximum
Maximum
VDC
VDC
VDC
%
W
A
A
A
mVpp
mVpp
mVpp
%
%
%
%
µF
µF
+/- 5
+/- 12
+/- 15
+/- 2
+/- 12,5
+/- 2,5
+/- 1
+/- 0,825
50
100
150
+/- 1
+/- 2,5
+/- 0,5
85
1.000
220
Conditions
Limit or
typical
Nominal
Min. - Max.
Min. - Max.
Maximum
Minimum
Maximum
Typical
Typical
Maximum
Units
Industrial
Grade
Bi Output MGDBI-25
25 - H
20
9-36
/
40/0,1
8,5
30
300
40
60
25 - O
48
18-75
/
80/0,1
17,5
30
300
40
60
Full temperature range
Full temperature range
Full temperature range
(Consult factory)
Full load
(Consult factory)
Full load
Ui nominal
Nominal output
Full load : resistive
Ui nominal, full load at
switching freq. BW = 20MHz
Ui nominal
Short-circuit
Ui nominal
No load
VDC
VDC
VDC
VDC/S
VDC
ms
mApp
mA
mA
+/- 5
+/- 12
+/- 15
+/- 2
+/- 12,5
+/- 2,5
+/- 1
+/- 0,825
50
100
150
+/- 1
+/- 2,5
+/- 0,5
85
1.000
220
5
Note * : For 9-36 VDC input range modules a derating has to be observed with a power decreasing linearly from 25W at 13 VDC down to 20W at 9 VDC input voltage.
Note ** : The ripple output voltage is the periodic AC component imposed on the output voltage, an aperiodic and random component (noise) has also to be considered. This
noise can be reduced by adding an external capacitor (typically 10nF/rated voltage depending on isolation requirement) connected between the pin Gin and the pin Gout of
the converter. This capacitor should be layed-out as close as possible from the converter.
Note *** : For load regulation characteristics from 0% to full load, please contact factory.
Data are valid at +25°C, unless otherwise specified.
Parameter
Input
Nominal input voltage
Permanent input
voltage range (Ui)
Extended permanent input
voltage range
Transient input voltage
Start up input voltage
Start up time
Reflected ripple current
Input current in short
circuit mode (Average)
No load input current
Output
Output voltage
Full temperature range
Ui min. to max.
75% load
Ambient temperature : +25°c
Ui nominal, 75% load
Full temperature range
Ui min. to max.
Full temperature range
Ui min. to max.
Nominal
Nominal
Nominal
Nominal
Maximum
Maximum
Maximum
Maximum
Maximum
Maximum
Maximum
Maximum
Maximum
Typical
Typical
Typical
Typical
Maximum
Maximum
VDC
VDC
VDC
VDC
%
W
A
A
A
A
mVpp
mVpp
mVpp
%
%
%
%
µF
µF
3,3 & +/- 12
3,3 & +/- 15
5 & +/- 11,5
5 & +/- 14,6
+/- 2
12,5 & +/- 6,25
3 & +/- 0,5
3 & +/- 0,4
2,5 & +/- 0,5
2,5 & +/- 0,4
50
100
150
+/- 1
+/- 3
+/- 0,5
80
2.200
100
Conditions
Limit or
typical
Nominal
Min. - Max.
Min. - Max.
Maximum
Minimum
Maximum
Typical
Typical
Maximum
Units
Industrial
Grade
Tri Output MGDTI-25
25 - H
20
9-36
/
40/0,1
8,5
30
300
40
60
25 - O
48
18-75
/
80/0,1
17,5
30
300
40
60
Full temperature range
Full temperature range
Full temperature range
(Consult factory)
Full load
Full load
Ui nominal
Nominal output
Full load : resistive
Ui nominal, full load at
switching freq. BW = 20MHz
Ui nominal
Short-circuit
Ui nominal
No load
VDC
VDC
VDC
VDC/S
VDC
ms
mApp
mA
mA
3,3 & +/- 12
3,3 & +/- 15
5 & +/- 11,5
5 & +/- 14,6
+/- 2
12,5 & +/- 6,25
3 & +/- 0,5
3 & +/- 0,4
2,5 & +/- 0,5
2,5 & +/- 0,4
50
100
150
+/- 1
+/- 3
+/- 0,5
83
2.200
100
Set Point accuracy
Output power
Output current *
3,3V & +/- 12V output
3,3V & +/- 15V output
5V & +/- 12V output
5V & +/- 15V output
Ripple output voltage **
3,3V and 5V output
12V output
15V output
Line regulation
5
Ui nominal
Full load
BW = 20MHz
Ui min. to max.
Full load
Ui nominal
Load regulation ****
25% to full load
Ui nominal
Cross load output regulation + Vout nominal load
- Vout from 25% to full load
Ui nominal
Efficiency
Full load
Maximum admissible
Ui nominal
Capacity load
Full load
3,3V and 5V output
Per output
12V and 15V output
Note * : For 9-36 VDC input range modules a derating has to be observed with a power decreasing linearly from 25W at 13 VDC down to 20W at 9 VDC input voltage.
Note ** : The ripple output voltage is the periodic AC component imposed on the output voltage, an aperiodic and random component (noise) has also to be considered. This
noise can be reduced by adding an external capacitor (typically 10nF/rated voltage depending on isolation requirement) connected between the pin Gin and the pin Gout of
the converter. This capacitor should be layed-out as close as possible from the converter.
Note *** : For load regulation characteristics from 0% to full load, please contact factory.
In this section, we will mainly explain from the following 3 aspects: 1. Preparation 2. How to mount Ubuntu system on the virtual machine 3. Just have fun 1. Preparation 1. A computer; 2. The virtual ...
[i=s]This post was last edited by sunduoze on 2021-4-17 23:51[/i]Objective: Build a basic development environment to realize the Arduino interface RS10-002GEVB board onboard LED flashing
Environment: ...
sunduozeonsemi and Avnet IoT Innovation Design Competition
[i=s]This post was last edited by dcexpert on 2015-8-14 10:25[/i] As far as I can remember, the topic of #Meeting Friends by Disassembling# seems to have started with the forum member [color=#333333][...
[size=4]Guess what Vout is in the picture? [/size]Everyone answer first, then look back for the answer:congratulate: [hide]Answer: Vin = 1V, Vout = -4V This is a bridge-tied load (BTL) circuit. The vo...
I have been playing with DE1-SoC for a while. The official controlPanel example shows how to install the tool chain and a set of procedures for developing QT interfaces with this board. I want to modi...
As LEDs continue to improve in almost every aspect of performance and cost, LED lighting is being used in an increasingly wide range of applications, among which LED street lights are a focus of in...[Details]
With the rapid development of urban economy, elevators are increasingly used as a vertical transportation tool. However, elevator fault detection and maintenance, especially the role of elevator remot...[Details]
LED is the abbreviation of light emitting diode, which is an electric light source made of semiconductor technology. The core part of LED is a chip composed of P-type semiconductor and N-type semi...[Details]
1 Introduction
In recent years, there have been many major advances in the production technology and processes of automotive headlights, which have greatly improved the performance of automoti...[Details]
Different initialization between C8051F and 80C51 series microcontrollers
In the past 30 years, major electronic component manufacturers in the world have launched their own unique single-chip...[Details]
It is well known to automotive suppliers that automakers are demanding more from their supply base. For connector suppliers, this means stricter requirements for product performance, stability and ...[Details]
The era of mobile access to the Internet has arrived, and it will rapidly change the business and infrastructure needs of mobile operators under a whole new trend of requirements. We need 4G LTE to...[Details]
D5026A is a driver IC designed by Shanghai Debei Electronics for energy-saving LED display screens. Its design concept is energy-saving and compatible with existing solutions, that is, it can be ...[Details]
Since AC mains power may experience power outages, voltage sags and surges, continuous undervoltage and overvoltage, and frequency fluctuations during supply, these factors will affect the continuous ...[Details]
1 Introduction to LED
With the development of science and technology, people have higher and higher requirements on automobile light sources. LED (Light Emitting Diode) has gradually attracted...[Details]
Almost everyone in a student dormitory has a bedside lamp. But if you want to read for a while after turning off the lights and don't want to disturb your roommates' sleep, you may need a reading l...[Details]
The fluorescent lamps and energy-saving lamps we commonly use now have greatly improved luminous efficiency compared with the earlier ordinary incandescent lamps and have been widely used. With the...[Details]
Today, with the increasing integration of functions, mobile phones can also be used as portable media players (PMP), digital cameras, handheld computers (PDAs), and even global positioning systems (GP...[Details]
1. Tips for charging UPS for the first time
After purchasing a new UPS, plug the UPS into the 220V mains power grid and charge it for at least 12 hours to ensure that the battery is fully char...[Details]
There are many types and styles of digital voltmeters in design and development. Traditional digital voltmeters have their own characteristics. They are suitable for manual measurement on site. Tra...[Details]