3. Epoxy meniscus may extend about 1mm (0.040”) down the leads.
Device Selection Guide
Iv (cd) @ 20mA
Part Number
HLMP-CW18-VY0xx
HLMP-CW19-VY0xx
HLMP-CW28-TW0xx
HLMP-CW29-TW0xx
HLMP-CW38-SV0xx
HLMP-CW39-SV0xx
Notes:
1. Tolerance for luminous intensity measurement is +/- 15%
2. The luminous intensity is measured on the mechanical axis of the lamp package.
3. The optical axis is closely aligned with the package mechanical axis.
4. LED light output is bright enough to cause injuries to the eyes. Precautions must be taken to prevent looking directly at the LED without proper safety
equipment.
Typ. Viewing Angle
Min.
15°
15°
23°
23°
30°
30°
4.20
4.20
2.50
2.50
1.90
1.90
Typ.
6.40
6.40
3.80
3.80
3.00
3.00
Standoff Leads
No
Yes
No
Yes
No
Yes
Package
Dimension
A
B
A
B
A
B
Part Numbering System
L M P - C W XX - X X X XX
Mechanical Option
00: Bulk
DD: Ammo Pack
Color Bin Options
0: Full color bin distribution
Maximum Intensity Bin Limit
0: No maximum intensity bin limit
Minimum Intensity Bin Limit
Refer to Device Selection Guide
Viewing Angle
18: 15 without standoffs
19: 15˚ with standoffs
28: 23˚ without standoffs
29: 23˚ with standoffs
38: 30 ˚ without standoffs
39: 30 ˚ with standoffs
Color Options
W: White
Package Options
C: T-1 3/4
2
Absolute Maximum Ratings (T
A
= 25°C)
Parameter
DC Forward Current
[1]
Peak Forward Current
[2]
Average Forward Current
Power Dissipation
LED Junction Temperature
Operating Temperature Range
Storage Temperature Range
Wave Solder Temperature
[3]
Solder Dipping Temperature
[3]
Notes:
1. Derate linearly as shown in Figure 4.
2. Duty Factor 30%, 1 KHz
3. 1.59 mm (0.060 inch) below body
Value
30
100
30
120
130
-40 to +85
-40 to +100
250 for 3 secs
260 for 5secs
Units
mA
mA
mA
mW
°C
°C
°C
°C
°C
Electrical/Optical Characteristics (T
A
= 25
o
C)
Parameters
Forward voltage
Capacitance
Reverse Voltage
[1]
Thermal resistance
Viewing Angle
[2]
CW18/CW19
CW28/CW29
CW38/CW39
Symbol
V
F
C
V
R
Rθ
J-PIN
2θ
1/2
15
23
30
0.31
0.32
I
F
= 20 mA
Minimum Typical
3.4
53
0.6
240
Maximum Units
4.0
V
pF
V
o
C/W
Test Condition
I
F
= 20 mA
V
F
=0, f=1 MHz
I
R
= 10
µA
LED Junction to cathode lead
I
F
= 20 mA
Degree
Chromaticity Coordinate
[3]
X
Y
Notes:
2. 2
θ
1/2
is the off-axis angle where the luminous intensity is ½ the on axis intensity
1. The reverse voltage of the product is equivalent to the forward voltage of the protective chip at I
R
= 10
µ
A
3. The chromaticity coordinates are derived from the CIE 1931 Chromaticity Diagram and represent the perceived color of the device.
A schematic diagram of a Bluetooth speaker found on the InternetNote:1. The resistors, capacitors, and diodes marked NC in the schematic diagram all indicate components that are not soldered on the PC...
The traffic light control system is designed using the 61 board and the traffic light module V3.0. The following functions are required: 1. The system has two states, the setting state and the display...
NTC thermistor temperature measurement, using the half-table lookup method, the microcontroller is stc12c5410ad with 10-bit AD, the table data ntctab[]=1024*Rm/(Rm+Rntc), the displayed result is 00, p...
Can bus, people who are engaged in automotive electronics should be very familiar with it. It is widely used in automobiles. Its stage name is control local area network. (Please search Baidu for the ...
Inverter power supply is called "tomorrow's power supply". Its application in welding equipment has brought revolutionary changes to the development of welding equipment. First, the inverter welding p...
The compiler I use is IAR FOR ARM. The chip I use is STM32. It's probably like this. The startup code changes the entry function. Reset_Handler LDR R0, =SystemInit ;BLX R0 LDR R0, =main ;Assembly labe...
Traditional broadcasting systems generally need to be operated manually at a fixed time, and can only realize one-way broadcasting with few functions. Traditional bell ringing equipment has a singl...[Details]
introduction
Since the beginning of the 21st century, the world of information has changed rapidly. Maybe a high-tech product will be released today and a better similar product will be releas...[Details]
1 Introduction
A wide variety of communication cables and control cables are widely used in various instruments and control equipment. Whether the cable is well-conducted and
whether
th...[Details]
1. Circuit composition
The whole circuit consists of two parts:
1. Power saving control circuit
As shown in the figure below. Including delay circuit and drive circuit.
(1) Delay ci...[Details]
1. Introduction
With the growth of parking demand, the scale of parking lots is becoming larger and larger. A lot of research has been done on intelligent parking lots in China, but most of th...[Details]
Converged processors meet scalability requirements
In current embedded system design, solutions based on MCU, DSP, FPGA and ASIC account for more than 90% of the market share. These solutions ...[Details]
The Portable Digital Data Acquisition System (PDDAS) uses LabVIEW Real-Time and PXI to control the wind tunnel test and record air pressure data from 128 different channels.
"The LabVIEW Real-...[Details]
This paper designs a dot matrix LED text display screen that is easy to update, expandable, and low-cost. The way to reduce costs is
① Use the Bluetooth data transmission function of mobile ph...[Details]
1. Introduction
With the gradual automation and modernization of industrial control systems, fieldbus control systems have received more and more attention and application. CAN bus is currentl...[Details]
We know that microcontroller development tools generally include real-time online emulators and programmers. Among them, online emulators are very good tools, but they are also more expensive...[Details]
Product series: PB-B-RS232/485 interface (hereinafter sometimes referred to as "interface") is a product in the PROFIBUS bus bridge series.
The main purpose of the bridge series ...[Details]
1 Introduction
Intelligent control instruments are one of the most commonly used controllers in industrial control. They are mainly aimed at a specific parameter (such as pressure, tempera...[Details]
1 Introduction
Building Automation System (BAS) is a distributed monitoring system (DCS) designed according to distributed information and control theory. It is the result of the mutual de...[Details]
1 Introduction
With the development of control, computer, communication, network technology, etc., a new control technology, namely fieldbus, has emerged in the field of industrial control...[Details]
1 Introduction
The Third Steel Plant of Jigang Group is a key investment project of Jigang Group during the "15th Five-Year Plan". It has introduced first-class domestic and foreign advanced eq...[Details]