EEWORLDEEWORLDEEWORLD

Part Number

Search

4SH8621

Description
Power/Signal Relay, 8PST, Momentary, 10A (Contact), 300VDC (Contact), AC/DC Output, DIN-Rail Mount
CategoryMechanical and electronic products    relay   
File Size219KB,4 Pages
ManufacturerFuji Electric Co., Ltd.
Download Datasheet Parametric View All

4SH8621 Overview

Power/Signal Relay, 8PST, Momentary, 10A (Contact), 300VDC (Contact), AC/DC Output, DIN-Rail Mount

4SH8621 Parametric

Parameter NameAttribute value
MakerFuji Electric Co., Ltd.
Reach Compliance Codeunknown
ECCN codeEAR99
body width43 mm
body height80 mm
Body length or diameter108 mm
Maximum coil voltage (AC)110 V
Contact (AC) maximum rated R load10A@600VAC
Maximum contact current (AC)10 A
Maximum contact current (DC)10 A
Contact (DC) maximum rated R load10A@300VDC
Maximum contact voltage (AC)600 V
Maximum contact voltage (DC)300 V
Contact/Output Power TypeAC/DC
Electrical life250000 Cycle(s)
Manufacturer's serial number4SH
Installation featuresDIN-RAIL MOUNT
physical size108mm x 43mm x 80mm
GuidelineBS; CSA; IEC, NEMA; UL; VDE
Relay actionMOMENTARY
Relay function8PST
Relay typePOWER/SIGNAL RELAY
surface mountNO
Termination typeSCREW
Base Number Matches1
"ORANGE LINE" INDUSTRIAL RELAY
Features and Ratings
FEATURES
NEW SH SERIES EXPANDABLE INDUSTRIAL RELAY
APPLICATIONS (U.S. Catalog No.4SH and 4GH Series)
High contact reliability that accommodates electronic devices.
All contacts are bifurcated, providing high contact reliability
(minimum operational voltage and current: 5V and 3mA DC)
and enabling direct input to an electronic control circuit.
A wide variety of optional units.
In addition to an auxiliary contact block (two or four poles),
many function units such as a coil surge suppression unit and
terminal covers can be installed on standard industrial relays.
This allows for flexibility and easy modification in the field.
Snap-on mounting on an IEC or DIN rail.
All models can be mounted on an IEC or DIN Standard
35mm rail.
Meets International Standards.
The SH Series industrial relays conform to the following
International Standards: IEC, NEMA, BS and VDE. They are
also UL, CSA, BV and Lloyd approved.
Compatible with conventional models.
SH Series industrial relays are compatible with the
discontinued Fuji SRCa50-3/X, SRCa50-3F/X, and SRC50-05/X
industrial relays. In addition to the mounting holes needed for
the compatibility, mounting holes based on the IEC Standard
are also provided.
Terminal numbers conforming to IEC Standards.
Terminal numbers are based on IEC Standards.
New design.
The arc extinguishing cover is ivory colored with orange
accents, providing a new look to the conventional industrial
relay.
AC OPERATED INDUSTRIAL RELAYS
U.S. Catalog No.
4SH440#
4SH431#
4SH422#
4SH880#
4SH871#
4SH862#
4SH853#
4SH844#
4SH550#
4SH541#
4SH532#
4SH523#
4SH514#
4SH505#
Aux. Contact
4NO
3NO+1NC
2NO+2NC
8NO
7NO+1NC
6NO+2NC
5NO+3NC
4NO+4NC
5NO
4NO+1NC
3NO+2NC
2NO+3NC
1NO+4NC
5NC
Fuji Type
SH-4
4 POLE
DC OPERATED INDUSTRIAL RELAYS
U.S. Catalog No.
4GH440#
4GH431#
4GH422#
4GH880#
4GH871#
4GH862#
4GH853#
4GH844#
4GH550#
4GH541#
4GH532#
4GH523#
4GH514#
4GH505#
Aux. Contact
4NO
3NO+1NC
2NO+2NC
8NO
7NO+1NC
6NO+2NC
5NO+3NC
4NO+4NC
5NO
4NO+1NC
3NO+2NC
2NO+3NC
1NO+4NC
5NC
Fuji Type
SH-4/G
4 POLE
SH-4
8 POLE
SH-4/G
8 POLE
SH-5
5 POLE
SH-5/G
5 POLE
EXPLANATION OF PART NUMBER SYSTEM
4 S H 4 2 2 #
APPROVAL
4= UL Listed
JIS Approved
OPERATION
S=AC Coil
G=DC Coil
COIL VOLTAGE
Select code from chart on next page
For AC: use Table 1
For DC: use Table 2
DESCRIPTION
QUANTITY OF N.C. AUX. CONTACTS
QUANTITY OF N.O. AUX. CONTACTS
TOTAL NUMBER OF CONTACTS
H=Industrial Relay
Five special classic friends to have in your life
There are five special classic friends in life. Except for true friends, there is no medicine that can reach the heart directly. Friends are constantly updated, just like clothes. This analogy does no...
jiaxinv92009 Talking about work
30th Anniversary of the Release of EEE 802.3(TM) Ethernet Standard
On June 23, 1983, IEEE, the world's largest professional technical association dedicated to technological development and benefiting mankind, commemorated the 30th anniversary of the release of the IE...
wstt Embedded System
Graphene, supercapacitors and 18650, if you still don’t understand, don’t go home for the New Year (Repost)
[i=s]This post was last edited by Bai Ding on 2016-2-5 22:59[/i] Reposted from [url=http://mp.weixin.qq.com/s?__biz=MjM5NDQ0NjM5Mg==&mid=401439742&idx=1&sn=6d2f09eeda89ca7617ecc34e0e6714a8&3rd=MzA3MDU...
白丁 Power technology
M4 Task 3: (Completed) Implement the display interface of three-axis accelerated ADC sampling on LCD
The three-axis acceleration on the MSP-EXP430FR5739 is very powerful! I decided to use it on the M4 board to measure the inclination! I worked hard all night and came up with an interface, which can b...
anananjjj Microcontroller MCU
How to define bit variables?
...
wacrt Microcontroller MCU
Problems with powering the microcontroller
How to draw a 220v AC to 5v DC conversion circuit? Can it be used to power a 51 microcontroller?...
396502099 Embedded System

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1488  1073  1935  428  1102  30  22  39  9  23 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号