EEWORLDEEWORLDEEWORLD

Part Number

Search

425F3XH019M9990

Description
Parallel - Fundamental Quartz Crystal, 19.999MHz Nom, GREEN COMPLIANT, CERAMIC, METAL, 4 PIN
CategoryPassive components    Crystal/resonator   
File Size228KB,3 Pages
ManufacturerCTS
Environmental Compliance
Download Datasheet Parametric View All

425F3XH019M9990 Overview

Parallel - Fundamental Quartz Crystal, 19.999MHz Nom, GREEN COMPLIANT, CERAMIC, METAL, 4 PIN

425F3XH019M9990 Parametric

Parameter NameAttribute value
Is it lead-free?Lead free
Is it Rohs certified?conform to
MakerCTS
package instructionGREEN COMPLIANT, CERAMIC, METAL, 4 PIN
Reach Compliance Codecompliant
Other featuresTAPE AND REEL
Ageing3 PPM/YEAR
Crystal/Resonator TypePARALLEL - FUNDAMENTAL
Drive level100 µW
frequency stability0.0015%
frequency tolerance30 ppm
JESD-609 codee4
load capacitance32 pF
Manufacturer's serial number425
Installation featuresSURFACE MOUNT
Nominal operating frequency19.999 MHz
Maximum operating temperature70 °C
Minimum operating temperature-20 °C
physical sizeL2.5XB2.0XH0.65 (mm)/L0.098XB0.079XH0.026 (inch)
Series resistance100 Ω
surface mountYES
Terminal surfaceGold (Au) - with Nickel (Ni) barrier
Base Number Matches1
Surface Mount Quartz Crystal
FEATURES
Standard 2.5x2.0mm Surface Mount Footprint
Stable Frequency Over Temperature and
Drive Level
Fundamental Crystal Design
Frequency Range 16 – 54 MHz
Frequency Tolerance, ±30 ppm Standard
(±10 ppm, ±15 ppm and ±20 ppm available)
Frequency Stability, ±50 ppm Standard
(±10,±15,±20,±30 and ±40 ppm available)
Operating Temperature to –40°C to +85°C
Tape & Reel Packaging, EIA-481-2 Compliant
RoHS/Green Compliant (6/6)
Model 425
DESCRIPTION
The Model 425 is a ceramic packaged Crystal
offering reduced size, ideal for high-density
circuit board applications. The Model 425 offers
reliable precision and excellent shock
performance in wireless telecommunication
devices.
ORDERING INFORMATION
425
MODE OF OSCILLATION
F = Fundamental
FREQUENCY TOLERANCE @ 25°C
1 = ± 10 ppm
X = ± 15 ppm
2 = ± 20 ppm
3 = ± 30 ppm (standard)
STABILITY TOLERANCE/TEMPERATURE RANGE
Over Operating Temperature Range
(Referenced to 25°C Reading)
M
FREQUENCY IN MHz
M - indicates MHz and decimal point.
Frequency is recorded with minimum 4
significant digits to the right of the "M".
LOAD CAPACITANCE
A = 10 pF
B = 13 pF
C = 16 pF
D = 18 pF
E = 20 pF
F = 24 pF
G = 30 pF
H = 32 pF
J = 9 pF
K = 8 pF
L = 12 pF
S = Series
1 = ± 10 ppm, -20°C to +70°C
X = ± 15 ppm, -20°C to +70°C
2 = ± 20 ppm, -20°C to +70°C
3 = ± 30 ppm, -20°C to +70°C
4 = ± 40 ppm, -20°C to +70°C
5 = ± 50 ppm, -20°C to +70°C (standard)
6 = ± 20 ppm, -40°C to +85°C
7 = ± 30 ppm, -40°C to +85°C
8 = ± 40 ppm, -40°C to +85°C
9 = ± 50 ppm, -40°C to +85°C
Example Part Numbers:
425F35E014M3181
425FX9A050M0000
Custom performance characteristics are available upon request.
Use form C052 to detail non-standard parameters.
Not all performance combinations and frequencies may be available.
Contact your local CTS Representative or CTS Customer Service for availability.
Document No. 008-0332-0
Page 1 - 3
Rev. B
٠ ٠ ٠
CTS Electronic Components, Inc.
٠
171 Covington Drive
٠
Bloomingdale, IL 60108
٠ ٠ ٠
٠ ٠ ٠
www.ctscorp.com
٠ ٠ ٠
ATMEGA8 Program
My program #include int main (void) { unsigned int i,j; DDRB = 0xff; PORTB = 0xfe; while (1) { PORTB = 0xfe; for(i=0;i500;i++) { for(j=0;j500;j++); } PORTB = 0xfd; for(i=0;i100;i++) { for(j=0;j50;j++)...
cyingzhu Microchip MCU
How does IPAM3402 read analog channel acquisition values and control analog output channels?
Read the acquired values of all 8 channels at onceSend command: 01 04 00 40 00 08 F0 18Among them, 01 is the module address,04 Read the function code of input analog quantity,00 40 Input analog channe...
qzairdzgs Industrial Control Electronics
I want to learn VXworks. Is there any good way to learn it?
I want to learn VXworks. Is there any good way to learn it? Please help me! ! !...
sdc666 Real-time operating system RTOS
MSP430F169 startup power consumption test
MSP430F169 is a low-power product that uses collected pulses to power the MSP430F169. It is found that the pulse energy is too small to meet the startup power consumption of the MCU and the program ca...
fish001 Microcontroller MCU
Is there any professional term for the switching power supply marked with a red circle in the picture?
My colleague asked me to test the voltage difference between the diode anode marked by the red circle and the busbar and 12Vo-. The waveform is as follows. Is this called clamping voltage? Switching n...
西里古1992 Analog electronics
EEWORLD University - How to use modern oscilloscopes to achieve accurate measurements (Part 4)
How to use modern oscilloscopes to achieve accurate measurements (Part 4) : https://training.eeworld.com.cn/course/439How to use modern oscilloscopes to achieve accurate measurements Part 4...
dongcuipin Test/Measurement

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1099  839  1515  442  2668  23  17  31  9  54 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号