EEWORLDEEWORLDEEWORLD

Part Number

Search

ASDX100A24H

Description
DIFFERENTIAL, PEIZORESISTIVE PRESSURE SENSOR, 0-5Psi, 2%, 0.50-4.50V, RECTANGULAR, THROUGH HOLE MOUNT
CategoryThe sensor   
File Size103KB,4 Pages
ManufacturerETC
Download Datasheet Parametric View All

ASDX100A24H Overview

DIFFERENTIAL, PEIZORESISTIVE PRESSURE SENSOR, 0-5Psi, 2%, 0.50-4.50V, RECTANGULAR, THROUGH HOLE MOUNT

ASDX100A24H Parametric

Parameter NameAttribute value
Maximum supply voltage5.25 V
Minimum supply voltage4.75 V
Maximum operating temperature105 Cel
Minimum operating temperature-20 Cel
Maximum accuracy2
Maximum operating pressure range5 Psi
Minimum operating pressure range0.0 Psi
Processing package descriptionDIP-8
Lead-freeYes
EU RoHS regulationsYes
stateACTIVE
outer coverplastic
high8.89 mm
width13.97 mm
terminal coatingNOT SPECIFIED
Installation featuresThrough hole mounting
Terminal typewelding
Working current6 mA
type of packagingRectangle
length or diameter16.89 mm
Linear2
Nominal offset0.50MV
Output range0.50-4.50V
Output typeANALOG voltage
port typestraight
Pressure sensing modedifferential
Response time8000 ms
Sensitivity800 mV/V
sensor typePEIZORESISTIVE
ASDX Series
0 to 1 psi through
0 to 100 psi
Pressure Transducers
APPLICATIONS
Medical
Instrumentation
Barometry
HVAC Controls
Pneumatic Controls
FEATURES
Piezoresistive Sensor
Precision ASIC
Conditioning
High Level Output
Temperature
Compensated
This ASDX series is an amplified version of SenSym
ICT’s proven performer and industry leading SDX
series sensor. This amplified ASDX device is in a
package with the slightly larger footprint as the
SDX but it offers a high level (4.0 V span) output
on a very cost effective basis. This family is fully
calibrated and temperature compensated using an
on-board ASIC. These sensors are intended for use
with non-corrosive, non-ionic working fluids; such
as air and dry gases.
Devices are available to measure absolute,
differential, and gage pressures from 1 psi
(ASDX01DN) through 100 psi (ASDX100). The
absolute devices have an internal vacuum reference
and an output voltage proportional to absolute
pressure. Differential devices allow application of
pressure to either side of the sensing diaphragm
and can be used for gage or differential
measurements.
All ASDX devices are accurate to within +/- 2.0%.
The devices are characterized for operation from a
single 5 volt supply. The sensor is designed and
manufactured according to standards laid down in
ISO 9001.
Contact your local SenSym ICT representative or
the factory for additional details.
0 TO 1 PSI THROUGH 0 TO 100 PSI PRESSURE TRANSDUCERS
SenSym ICT
MAX3000 series pin diagram
I'm a new student of CPLD. I have a few EPM3064s. I've searched the Internet for a long time but couldn't find the pinout diagram. Can anyone who knows please give me some pointers? Thanks!...
centipede FPGA/CPLD
The 2nd NXP Cup Innovation Design Competition
[i=s]This post was last edited by paulhyde on 2014-9-15 09:48[/i] [img=585,262]http://www.eepw.com.cn/event/action/nxp/images/index_03.jpg[/img] [table=98%][tr][td=1,1,399][table=98%][tr][td]Event Int...
sunshine0410 Electronics Design Contest
Oscilloscope noise floor measurement and setting factors that affect noise floor
The lower the noise floor of an oscilloscope, the better. However, the noise floor measurement is affected by various factors. When comparing oscilloscopes, it is meaningless to look at only one param...
Micsig麦科信 Test/Measurement
How to use the national standard font library (HZK16, ASC16) to basically solve the Chinese display problem under Micropython
[i=s]This post was last edited by lemon1394 on 2021-8-23 23:37[/i]There are many problems with fonts. Many netizens' methods have their own advantages and disadvantages, which are summarized as follow...
lemon1394 MicroPython Open Source section
Read SD card font library to display Chinese characters
It doesn't really make sense, so I'll just post two pictures....
shower.xu Microcontroller MCU
LED lamp life does not exceed 12,000 hours?
As we all know, LED lamps use semiconductor principles, and their light source life is very long, up to 50,000 hours or more. However, I recently communicated with a senior in the energy-saving lamp i...
ring LED Zone

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 637  688  31  774  2111  13  14  1  16  43 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号