Description
Electromechanical Relay, DPDT, 138VDC (Coil), Random, AC/DC Output
CategoryMechanical and electronic products    relay   
File Size2MB,10 Pages
ManufacturerFINDER
Download Datasheet Parametric View All

56.42.9.125.20741 Overview

Electromechanical Relay, DPDT, 138VDC (Coil), Random, AC/DC Output

56.42.9.125.20741 Parametric

Parameter NameAttribute value
MakerFINDER
Reach Compliance Codecompliant
body width20.7 mm
body height36.8 mm
Body length or diameter27.7 mm
Coil operating voltage (DC)100 V
Coil resistance17300 Ω
Maximum coil voltage (DC)138 V
Nominal coil voltage125 V
Coil/Input Power TypeDC
Contact (AC) maximum rated R load20A@400VAC
Maximum contact current (AC)20 A
Maximum contact voltage (AC)400 V
Contact/Output Power TypeAC/DC
Dielectric strength between coil and contacts4000 Vrms
Dielectric strength between breaking contacts1000 Vrms
Electrical life100000 Cycle(s)
End contact materialSilver Cadmium Oxide
Input switching control typeRandom
Number of terminals8
operating hours8 ms
PCB hole count8
physical size27.7mm x 20.7mm x 36.8mm
GuidelineCSA; IMQ; PCT; UL; VDE
Relay functionDPDT
release time3 ms
Terminal length0.0043 inch
Termination typeSOLDER
Base Number Matches1
56
56 Series - Miniature power relays 12 A
Features
Plug-in - 12 A Power relay, 2 & 4 pole
Flange mount option -
(Faston 187, 4.8x0.5 mm termination)
AC coils & DC coils
Lockable test button and mechanical flag indicator
Cadmium Free contacts (standard version)
Contact material options
96 series sockets
Coil EMC suppression
Accessories
European Patent
SERIES
56.32/56.34
56.32-0300
Plug-in / PCB Relays
1
2 or 4 pole changeover contact
Plug-in/Faston 187
2 pole normally open contact
(≥1.5 mm gap)
Plug-in/Faston 187
56.32
56.32-0300
56.34
* For 4 CO (4PDT) only.
F
OR
UL
RATINGS SEE
:
“General technical information” page
V
Contact specification
Contact configuration
Rated current/Maximum peak current
Rated load AC1
Rated load AC15 (230 V AC)
Single phase motor rating (230 V AC)
Breaking capacity DC1: 30/110/220 V
Minimum switching load
Standard contact material
Coil specification
Nominal voltage (U
N
)
Rated power AC/DC
Operating range
Holding voltage
Must drop-out voltage
Technical data
Mechanical life AC/DC
Electrical life at rated load AC1
Operate/release time
XI-2013, www.findernet.com
56.32
56.34
56.32-0300
2 CO (DPDT)
A
VA
VA
kW
A
12/20
250/400
3,000
700
0.55
4 CO (4PDT)
2NO (DPST-NO) -
≥1.5mm
gap
12/20
250/400
3,000
700
0.55
12/1/0.5
500 (10/5)
AgNi
Rated voltage/Maximum switching voltage V AC
12/0.5/0.25
500 (10/5)
AgNi
mW (V/mA)
V AC (50/60 Hz)
V DC
VA (50 Hz)/W
AC
DC
AC/DC
AC/DC
cycles
cycles
ms
V AC
°C
8/3
4
1.5/1
6 - 12 - 24 - 48 - 60 - 110 - 120 - 230 - 240 - 400*
6 - 12 - 24 - 48 - 60 - 110 - 125 - 220
2/1.3
(0.8…1.1)U
N
(0.8…1.1)U
N
(0.85…1.1)U
N
0.8 U
N
/0.6 U
N
0.2 U
N
/0.1 U
N
20 · 10
6
/50 · 10
6
100 · 10
3
10/4
5
1,000
–40…+70
RT I
1.5/—
(0.85…1.1)U
N
0.85 U
N
/—
0.2 U
N
/—
20 · 10
6
/—
100 · 10
3
8/4
4
2,000
–40…+70
RT I
Insulation between coil and contacts (1.2/50 µs) kV
Dielectric strength between open contacts
Ambient temperature range
Environmental protection
Approvals
(according to type)
Don't rely on technology for your whole life
I am doing it myself now, but I have been engaged in software development for many years before. When I think about myself, I want to say something to those friends who are just starting to learn JAVA...
eeleader Talking about work
The road to sharing smartphone software!
I am very interested in smartphone software. I would like to invite you to discuss the sharing of smartphone software... As major mobile phone manufacturers adopt Microsoft's Windows CE and smartphone...
qigan Embedded System
Transfer: Microsoft announced a new feature of IE9: Tracking protection to protect user privacy
Forward: Microsoft announces new feature of IE9: Tracking Protection protects user privacy Microsoft has just launched a new IE9 feature: Tracking Protection. The Tracking Protection feature can furth...
光头李 Embedded System
Help with RC phase shift circuit design
[font=verdana][size=13px]I just looked at the parameters of an RC phase shift network (as shown below). After calculation, I found that F=1/(2πRC), where F is the input frequency. From a design point ...
mrf245 Analog electronics
MSP430G2xx3 Code Examples
It feels pretty good, for beginners!...
william228 Microcontroller MCU
SPI synchronous communication cannot be established, it's terrible, I beg for help from an expert!
[code] Declaration of serial synchronous communication:// Initialize the MSP430 SPI// SPI clock selects the highest frequency of DCOCLK, between 8M-10M; because the external XT2=8M crystal oscillator,...
yylooker Microcontroller MCU

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 626  2327  1496  285  1681  13  47  31  6  34 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号