36-002-184X Overview

Interconnection Device

36-002-184X Parametric

Parameter NameAttribute value
MakerAries Electronics
Reach Compliance Codecompliant
Other featuresNO. OF CONTACTS: 36, MALE-FEMALE, 94V-0
Connector typeINTERCONNECTION DEVICE
Base Number Matches1
Series 181 Thru 184
Flat Pin Staked Flex Jumpers
FEATURES:
• Aries 90° Pin Staked Flex Jumpers combine thin, flexible, solid
E
IM
Copper conductors embedded between layers of tough, flexible,
T
flame-retardant insulation.
IS
TH
• Consult factory for cable lengths under 2.000 [50.80].
T
GENERAL SPECIFICATIONS:
EA
L
• Standard cable insulation is white UL VW-1, Style 2643 flame
AB
IL
retardant Polyester (Mylar) adhesive.
VA
• High temperature flame retardant cable insulation is Polyimide
EA
(Kapton) insulation with acrylic adhesive.
R
TU
• Cable conductors are solid Copper with a cross-sectional area
PIC
equivalent to that of 26 gauge AWG.
• Female housing is black UL 94V-0 Glass-filled Thermoplastic
NO
Polyester.
• Female and male “crimp-on” pins are spring-tempered Copper
Note: Aries specializes in custom design and production. In addition to the
Alloy 510.
standard products shown on this page, special materials, platings, sizes, and
• Female and male pin plating is 100µ [2.54µm] min. Tin per MIL-T-
configurations can be furnished, depending on quantities. Aries reserves the
10727 over 50µ [1.27µm] min. Nickel per QQ-N-290. Female pin
right to change product specifications without notice.
also available with 30µ [.76µm] min. Gold per MIL-G-45204 in
ORDERING INFORMATION
contact area.
• Cable current rating=3 Amps
X X - X X X X - 1 8 X X X X
Optional Suffix:
No. of
• Cable voltage rating=300 Volts
HT-High temp.
• Cable dielectric strength=2500 Volts/mil, minimum (standard)
Conductors
cable insula-
=4000 Volts/mil, minimum (high temp)
(4 thru 40)
tion
• Cable insulation resistance=1000 MOhms minimum (standard)
Cable Length
=100,000 MOhms (high temp)
Jumper Series:
“L” in inches
Operating temperature=67 to 257°F [-55 to 105°C].
181: male Tin both ends
(min. Length
• Female housing accepts leads .024-.030 [.61-.76] square,
182: male Tin/female Tin
=2.00 [50.80]
.150 [3.81] long minimum.
183: female Tin both ends
MOUNTING CONSIDERATIONS:
184: male Tin/female Gold
• Suggested PCB hole size=.032+ .002 [.81 + .05] dia.
185: female Gold both ends
“A”=NO. OF CONDUCTORS X .100 [2.54]
“B”=(NO. OF CONDUCTORS -1) X .100 [2.54]
Kapton is a registered trademark for DuPont
**Aries reserves the right to shop with
or without a polarization stripe nless
otherwise specified by customer
A
LL
DIMENSIONS
:
INCHES
[
MILLIMETERS
]
All tolerances ± .005 [.13]
unless otherwise specified
REV. A
PRINTOUTS OF THIS DOCUMENT MAY BE OUT OF DATE AND SHOULD BE CONSIDERED UNCONTROLLED
http://www.arieselec.com • info@arieselec.com
NORTH AMERICA
Frenchtown, NJ USA
TEL: (908) 996-6841
FAX: (908) 996-3891
UK/IRELAND/GB
TEL: +44 870 240 0249
FAX: +44 1653 600493
uking@arieselec.com
EUROPE/MAINLAND/HOLLAND
TEL: +31 78 615 94 65
FAX: +31 78 615 43 11
11019
europe@arieselec.com
Contents and characteristics of electrical testing
Electrical testing refers to all tests performed using electrical technology and tests performed on electrical systems and equipment (motors, electrical appliances, etc.). Electrical testing usually i...
一世轮回 Integrated technical exchanges
Generation of static electricity
Matter is composed of molecules, which are composed of atoms. Atoms are composed of negatively charged electrons and positively charged protons. Under normal conditions, the number of protons in an at...
wangqingtao Power technology
When the stc89c52 microcontroller uses external interrupt 0, can't ET1 be set to 1?
I used protues to simulate and found that when I used external interrupt 0 and turned on the overflow interrupt of timer 1 (ET1=1), the external interrupt would not be triggered and could only be set ...
赵怡彬 51mcu
How to measure the frequency converter accurately
Many users have reported that the input or output current and voltage values of the inverter measured by a multimeter are quite different from the rated values displayed on the inverter nameplate or m...
totopper Industrial Control Electronics
Wireless module 24L01 data and 51 program
[i=s] This post was last edited by paulhyde on 2014-9-15 04:04 [/i] Wireless module 24L01 information...
haozi_1989 Electronics Design Contest
Development of an intelligent high-voltage inverter DC power supply for electrostatic precipitator
Abstract: This paper introduces a high voltage inverter power supply for electrostatic precipitator. The main structure of the power supply, the working principle of the main circuit, and the working ...
binghuoshaonian Power technology

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 596  792  2159  1175  1815  12  16  44  24  37 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号