The UT54ACS163 and the UT54ACTS163 are synchronous
presettable 4-bit binary counters that feature internal carry look-
ahead logic for high-speed counting designs. Synchronous op-
eration occurs by having all flip-flops clocked simultaneously
so that the outputs change coincident with each other when in-
structed by the count-enable inputs and internal gating. A buff-
ered clock input triggers the four flip-flops on the rising (posi-
tive-going) edge of the clock input waveform.
The counters are fully programmable (i.e., they may be preset
to any number between 0 and 15). Presetting is synchronous;
applying a low level at the load input disables the counter and
causes the outputs to agree with the load data after the next clock
pulse.
The clear function is synchronous and a low level at the clear
input sets all four of the flip-flop outputs low after the next clock
pulse. This synchronous clear allows the count length to be mod-
ified by decoding the Q outputs for the maximum count desired.
The counters feature a fully independent clock circuit. Changes
at control inputs (ENP, ENT, or LOAD) that modify the operat-
ing mode have no effect on the contents of the counter until
clocking occurs. The function of the counter (whether enabled,
disabled, loading, or counting) will be dictated solely by the
conditions meeting the stable setup and hold times.
The devices are characterized over full military temperature
range of -55°C to +125°C.
1
PINOUTS
16-Pin DIP
Top View
CLR
CLK
A
B
C
D
ENP
V
SS
1
2
3
4
5
6
7
8
16
15
14
13
12
11
10
9
V
DD
RCO
Q
A
Q
B
Q
C
Q
D
ENT
LOAD
16-Lead Flatpack
Top View
CLR
CLK
A
B
C
D
ENP
V
SS
1
2
3
4
5
6
7
8
16
15
14
13
12
11
10
9
V
DD
RCO
Q
A
Q
B
Q
C
Q
D
ENT
LOAD
LOGIC SYMBOL
(1)
CLR
(9)
LOAD
ENT
ENP
CLK
A
B
C
D
(10)
(7)
(2)
(3)
(4)
(5)
(6)
CTRDIV 16
5CT=0
M1
M2
3CT = 15
G3
G4
C5/2,3,4+
1,5D
(1)
(2)
(4)
(8)
(14)
(13)
(12)
(11)
Q
A
Q
B
Q
C
Q
D
(15)
RCO
Note:
1. Logic symbol in accordance with ANSI/IEEE Std 91-1984 and IEC Publi-
cation 617-12.
FUNCTION TABLE
Operating Mode
Reset (Clear)
Parallel Load
CLR
l
h
3
h
3
Count
Inhibit
h
3
h
3
h
3
CLK
↑
↑
↑
↑
ENP
X
X
X
h
l
2
X
ENT
X
X
X
h
X
l
2
LOAD
X
l
l
h
h
3
h
3
DATA A,B,C,D
X
l
h
X
X
X
Q
N
L
L
H
Count
Q
N
Q
N
RCO
L
L
1
1
1
X
X
L
H = High voltage level h = High voltage level one setup time prior to the low-to-high clock transition
L = Low voltage level
l
= Low voltage level one setup time prior to the low-to-high clock transition
Notes:
1. The RCO output is high when ENT is high and the counter is at terminal count HHHH.
2. The high-to-low transition of ENP or ENT should only occur while CLK is high for conventional operations.
3. The low-to-high transition of LOAD or CLR should only occur while CLK is high for conventional operations.
LOGIC DIAGRAM
(2)
(1)
D
C
Q
Q
CLK
CLR
(14)
Q
A
(9)
LOAD
(7)
ENP
(10)
ENT
(3)
DATA A
D
C
Q
Q
(13)
Q
B
DATA B
(4)
D
C
Q
Q
(12)
Q
C
DATA C
(5)
D
C
Q
Q
(11) Q
D
DATA D
(6)
(15)
RCO
2
OPERATIONAL ENVIRONMENT
1
PARAMETER
Total Dose
SEU Threshold
2
SEL Threshold
Neutron Fluence
LIMIT
1.0E6
80
120
1.0E14
UNITS
rads(Si)
MeV-cm
2
/mg
MeV-cm
2
/mg
n/cm
2
Notes:
1. Logic will not latchup during radiation exposure within the limits defined in the table.
2. Device storage elements are immune to SEU affects.
ABSOLUTE MAXIMUM RATINGS
SYMBOL
V
DD
V
I/O
T
STG
T
J
T
LS
Θ
JC
I
I
P
D
PARAMETER
Supply voltage
Voltage any pin
Storage Temperature range
Maximum junction temperature
Lead temperature (soldering 5 seconds)
Thermal resistance junction to case
DC input current
Maximum power dissipation
LIMIT
0.3 to 7.0
-.3 to V
DD
+.3
-65 to +150
+175
+300
20
±10
1
UNITS
V
V
°C
°C
°C
°C/W
mA
W
Note:
1. Stresses outside the listed absolute maximum ratings may cause permanent damage to the device. This is a stress rating only, functional operation of the
device at these or any other conditions beyond limits indicated in the operational sections is not recommended. Exposure to absolute maximum rating
conditions for extended periods may affect device reliability.
RECOMMENDED OPERATING CONDITIONS
SYMBOL
V
DD
V
IN
T
C
PARAMETER
Supply voltage
Input voltage any pin
Temperature range
LIMIT
4.5 to 5.5
0 to V
DD
-55 to + 125
UNITS
V
V
°C
3
DC ELECTRICAL CHARACTERISTICS
7
(V
DD
= 5.0V
±
10%; V
SS
= 0V
6
, -55°C < T
C
< +125°C); Unless otherwise noted, Tc is per the temperature range ordered.
SYMBOL
V
IL
PARAMETER
Low-level input voltage
1
ACTS
ACS
High-level input voltage
1
ACTS
ACS
Input leakage current
ACTS/ACS
Low-level output voltage
3
ACTS
ACS
High-level output voltage
3
ACTS
ACS
Short-circuit output current
2 ,4
ACTS/ACS
Output current
10
(Sink)
I
OH
Output current
10
(Source)
P
total
I
DDQ
ΔI
DDQ
Power dissipation
2, 8, 9
Quiescent Supply Current
Quiescent Supply Current Delta
ACTS
V
IN
= V
DD
or V
SS
I
OL
= 8.0mA
I
OL
= 100μA
I
OH
= -8.0mA
I
OH
= -100μA
V
O
= V
DD
and V
SS
V
IN
= V
DD
or V
SS
V
OL
= 0.4V
V
IN
= V
DD
or V
SS
V
OH
= V
DD
- 0.4V
C
L
= 50pF
V
DD
= 5.5V
For input under test
V
IN
= V
DD
- 2.1V
For all other inputs
V
IN
= V
DD
or V
SS
V
DD
= 5.5V
C
IN
C
OUT
Input capacitance
5
Output capacitance
5
ƒ
= 1MHz @ 0V
ƒ
= 1MHz @ 0V
15
15
pF
pF
1.9
10
1.6
mW/
MHz
μA
mA
-8
mA
.7V
DD
V
DD
- 0.25
-200
8
200
.5V
DD
.7V
DD
-1
1
CONDITION
MIN
MAX
0.8
.3V
DD
UNIT
V
V
IH
V
I
IN
V
OL
μA
0.40
0.25
V
V
OH
V
I
OS
I
OL
mA
mA
4
Notes:
1. Functional tests are conducted in accordance with MIL-STD-883 with the following input test conditions: V
IH
= V
IH
(min) + 20%, - 0%; V
IL
= V
IL
(max) + 0%, -
50%, as specified herein, for TTL, CMOS, or Schmitt compatible inputs. Devices may be tested using any input voltage within the above specified range, but are
guaranteed to V
IH
(min) and V
IL
(max).
2. Supplied as a design limit but not guaranteed or tested.
3. Per MIL-PRF-38535, for current density
≤
5.0E5 amps/cm
2
, the maximum product of load capacitance (per output buffer) times frequency should not exceed 3,765
pF/MHz.
4. Not more than one output may be shorted at a time for maximum duration of one second.
5. Capacitance measured for initial qualification and when design changes may affect the value. Capacitance is measured between the designated terminal and V
SS
at
frequency of 1MHz and a signal amplitude of 50mV rms maximum.
6. Maximum allowable relative shift equals 50mV.
7. All specifications valid for radiation dose
≤1E6
rads(Si).
8. Power does not include power contribution of any TTL output sink current.
9. Power dissipation specified per switching output.
10. This value is guaranteed based on characterization data, but not tested.
Here is a basic tutorial of Protel DXP, I hope it will be useful to you, including multi-channel design, global editing, component creation, reports, etc....
After the NAND-based WM system is established, there are two areas on the mobile phone resource manager, one can be erased, and the other cannot be erased even if the factory settings are restored. HT...
My USB flash drive is displayed when it is plugged in. But if you click it, a dialog box pops up: Please enter disk F. What is going on? How can I fix it?...
To those who want to learn microcontrollers: Before you decide to learn microcontrollers, please do the following preparations: 1. Hardware preparation: The equipment I recommend to everyone for l...
When I was studying the ARM architecture (English name: ARM Architecture Reference Manua), I suddenly had an idea: ARM has been around for so many years, and its architecture has been constantly devel...
1. Project Overview
1.1 Introduction
Currently, most music files are saved in MP3 format, a lossy audio compression format that cannot perfectly reproduce the original music. With the exp...[Details]
In recent years, with the application of the IEC61850 standard and the development and deployment of optoelectronic transformers, the concept of digital substations has been put into practical use ...[Details]
Current Development Status of DVR Market
A DVR, or digital video recorder, uses a hard disk for recording, unlike traditional analog video recorders. It's often called a DVR because it's a com...[Details]
On August 18th, Galaxis, a specialist in integrated intelligent intralogistics robotics, officially unveiled its next-generation, ultra-narrow aisle forklift mobile robot, the "VFR Ultra-Narrow Ser...[Details]
Laird Thermal Systems has introduced the HiTemp ET series Peltier cooler modules, which can operate at high temperatures and provide on-site cooling for sensitive electronic devices.
Dig...[Details]
A half-bridge is an inverter topology for converting DC to AC. A typical half-bridge circuit consists of two controller switches, a three-wire DC power supply, two feedback diodes, and two capacito...[Details]
Through AI connection technology supported by Qualcomm X85 5G modem and RF and Qualcomm FastConnect 7900 mobile connection system, seamless switching can be achieved between cellular net...[Details]
A pure sine wave inverter has a good output waveform with very low distortion, and its output waveform is essentially the same as the AC waveform of the mains power grid. In fact, the AC power prov...[Details]
Electric vehicles will revolutionize transportation, changing fuel consumption, carbon emissions, costs, maintenance, and driving habits. Currently, a major selling point for electric vehicles is t...[Details]
Wearable technology is taking off, with applications evolving rapidly, from smartwatches to fitness trackers and even smart wigs! Bluetooth Smart is at the center of this revolution. This is the se...[Details]
introduction
With the development of society, people's requirements for the quality of refrigerated and frozen foods are constantly improving. The changes in food appearance and nutritional co...[Details]
introduction
The widespread use of air conditioner communication circuits began with the rise of household inverter air conditioners. With China's energy conservation and emission reduction in...[Details]
introduction
A common voltage regulator is a three-terminal one. Its function is to step down the voltage and stabilize it at a fixed output value. Voltage regulators are commonly available in...[Details]
0 Introduction
With a rapidly aging population, a young couple is now required to care for an increasing number of elderly people, leading to a growing difficulty in providing care for them. E...[Details]
The automotive driveshaft is a crucial connecting component in the automotive mechanical system. It is a circular component that allows for connection or assembly, as well as movement and rotation....[Details]