Mallory Sonalert Products, Inc.
Sales Outline Drawing
Specifications:
Stack Number:
LED Color:
Connection Wires:
LED Current Draw:
Rated Voltage:
Operating Voltage:
Sound Level Category:
Mode of Operation:
Connection:
Sound Current Draw:
Loudness @ 1m:
Frequency:
Total Max Current:
Operating Temperature:
Lens Color:
Material:
Mounting Method:
Weight Typical (g):
NEMA 12:
Options:
1
RED
Red and Brown
<50mA
24 VAC/DC
20-28 VAC/DC
Loud
Part #:
Revision:
JT028-R-CDL
B
Loud
Continuous
Loud
Medium Pulse (5PPS)
Black and Gray Wires;
Black and Gray
Orange wire connected
Wires
to Green/Yellow wire
40mA Max.
40mA Max.
Double Pulse (0.5PPS)
Black and Gray Wires;
Purple wire connected to
Green/Yellow wire
40mA Max.
80-85 dB(A) Typ.
2000 ± 500 Hz
<90mA with all LED's and Sound unit working
-25° ~ +60°C
Opaque White
ABS FR15U
Direct Mount using 1/2" NPT Stainless Steel Pipe and Nut
270
Approved
Please contact factory.
Loud
Continuous for 5 sec then 0.1s
beep until reset
Black and Gray wires; Orange and
Purple wires connected to
Green/Yellow wire
40mA Max.
Dimensions:
Inches (mm)
cUL Recognized
ROHS Compliant
LED OPERATION:
CONNECT STACK COLOR WIRE TO POWER AND BROWN WIRE TO POWER.
CONNECT GRAY AND BLACK WIRES TO POWER FOR CONTINUOUS SOUND.
FOR MEDIUM PULSE, CONNECT GRAY & BLACK TO POWER AND ORANGE WIRE TO
GREEN/YELLOW WIRE.
FOR DOUBLE PULSE, CONNECT GRAY & BLACK TO POWER AND PURPLE WIRE TO
GREEN/YELLOW WIRE.
FOR CONT/BEEP, CONNECT GRAY & BLACK TO POWER AND ORANGE & PURPLE TO
GREEN/YELLOW WIRE.
SOUND OPERATION:
4411 South High School Road, Indianapolis, Indiana 46241 U.S.A · Phone: (317) 612-1000 Fax: (317) 612-1010
www.mallory-sonalert.com