EEWORLDEEWORLDEEWORLD

Part Number

Search

0JTD030T

Description
Industrial & Electrical Fuses 30A 600VAC Class J
CategoryCircuit protection   
File Size253KB,3 Pages
ManufacturerLittelfuse
Websitehttp://www.littelfuse.com
Download Datasheet Parametric View All

0JTD030T Online Shopping

Suppliers Part Number Price MOQ In stock  
0JTD030T - - View Buy Now

0JTD030T Overview

Industrial & Electrical Fuses 30A 600VAC Class J

0JTD030T Parametric

Parameter NameAttribute value
Product AttributeAttribute Value
ManufacturerLittelfuse
Product CategoryIndustrial & Electrical Fuses
RoHSN
ProductClass J Fuse
Current Rating30 A
Voltage Rating AC600 VAC
Fuse TypeTime Delay / Slow Blow
Voltage Rating DC300 VDC
Body StyleCartridge Fuses
Mounting StyleHolder
Termination StyleClip
Fuse Size / GroupPOWR-PRO
Indicator StyleWithout Indicator
PackagingBulk
TypePower Guard
Interrupt Rating200 kA at 600 VAC
Factory Pack Quantity1
POWR-PRO
®
Fuses
JTD_ID Series Indicator
®
POWR-PRO
®
Class J Fuses
600 VAC • Time Delay • 8/10 – 600 Amperes
Applications
POWR-PRO
®
Fuses
Fused combination motor controllers to provide IEC Type 2 (“No
Damage”) motor branch circuit short-circuit and ground fault
protection
Motor control centers
Transformer protection
Protection for UL Listed series rated molded case circuit breaker panels
General purpose circuits — mains, feeders and branch circuits —
especially when space is limited.
Features/Benefits
• Reduce downtime — A glance at the indicating window of a JTD_ID
Indicator fuse pinpoints open fuses immediately. If the indicating
window is dark, the fuse has opened. It’s that simple.
• Reduce nuisance opening — Indicator fuses have superior time-delay
and cycling characteristics which can lengthen fuse life and decrease
needless opening.
• Reduce fuse inventory — JTD_ID Indicator fuses have superior
performance characteristics, which means they can be used on a
variety of applications; therefore, decreasing fuse inventory.
• Reduce equipment damage — Indicator fuses provide superior
overload and short-circuit protection that can reduce equipment
damage. Indicator fuses also provide IEC Type 2 “No Damage”
protection to IEC and NEMA type motor starters.
• Reduce accidents — The JTD_ID Indicator fuse improves safety
by minimizing exposure to live circuits. Unlike other forms of blown
fuse indication, once the indicating window darkens, it stays dark. It
does not matter if the power is on or off or if the fuse is in a tool box.
Other forms of indication require the power to remain on, which is a
safety hazard for personnel.
The Littelfuse POWR-PRO JTD_ID Indicator Class J fuse provides visual
blown fuse indication and maximum protection in a compact package.
The compact Class J package was designed specifically for circuits
where space is at a premium. The current-limiting time delay JTD_ID
offers a patented, true dual-element design that is ideal for use in circuits
with high, in-rush currents. The Superior performance characteristics of
JTD_ID Indicator fuses reduce nuisance fuse opening, and the blown
fuse indication reduces downtime while increasing safety.
Specifications
Voltage Ratings:
AC: 600 Volts
DC: 300 Volts (
8
10 –
100A)
500 Volts (110 – 600A)
AC: 200,000 amperes rms symmetrical
300,000 amperes rms symmetrical
(Littelfuse self-certified)
8/10 – 600 amperes
AC: Standard 248-8, Class J
ULListed (File No: E81895)
CSA Certified (File No: LR29862)
DC: Littelfuse self-certified
8
10
- 100A: 300VDC self certified
110 – 600A: 500VDC self certified
Ampere Ratings
10
1
1
1
4
1
1
2
1
6
10
1
8
10
2
2
1
4
2
1
2
8
Interrupting Ratings:
Ampere Range:
Approvals:
2
8
10
3
2
3 ⁄
10
3
1
2
4
4
1
2
5
5
6
10
6
7
8
9
10
12
15
17
1
2
20
25
30
35
40
45
50
60
70
80
90
100
110
125
150
175
200
225
250
300
350
400
450
500
600
Example part number (series & amperage): JTD 60 ID
Recommended Fuse Blocks
LJ600 series, LPSJ series
Refer to Blocks & Holders section of this catalog for additional information.
© 2005 Littelfuse
POWR-GARD
Products Catalog
www.littelfuse.com

Ask about the communication interface between FPGA and PC
RS232 serial port is the simplest, but the speed is slow; What are the advantages of using EPP/ECP parallel port to transmit data and USB bus to transmit data in terms of development difficulty and co...
darkkingdom Embedded System
CCS : Can't write to data memory 0x3FB1DA, check memory config [-2184]
I use CCS to develop a program based on the c28xx simulator. After the program is compiled successfully, the error " Can't write to data memory 0x3FB1DA, check memory config [-2184]" appears . Please ...
shiker2003 TI Technology Forum
Moving, unpacking! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! !
[color=#ff0000]All the following items are not refundable and are not under warranty! ! Please read carefully before ordering, thank you! If you need it, just buy it from me directly, don't be long-wi...
shanyan Buy&Sell
What are the high frequency characteristics of capacitors?
[size=4] First of all, high frequency and low frequency are relative. If the frequency is too high, then it is meaningless to make the capacitance of the capacitor larger, because, as we all know, the...
fish001 Analogue and Mixed Signal
I wrote a basic stream driver, but why can't it be activated in DM?
The code is as follows*********************GIO_DRV.h**************************************** #include "stdafx.h" #include__declspec(dllexport) extern DWORD GIO_Init1(LPCTSTR pContext, LPCVOID lpvBusCo...
wangjunaza Embedded System
I have some idle MCU development boards, ATMEGA128 and 8051 development boards for sale at a low price. If you need them, please contact me.
[i=s]This post was last edited by Development Board Home on 2015-1-18 23:02[/i]...
开发板之家 Buy&Sell

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 867  947  2158  2702  742  18  20  44  55  15 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号