3130-F130-P7T1-W01Q-08A

Description
Circuit Breakers Thermal circuit breaker with rocker actuation, single, double or three pole
CategoryCircuit protection   
File Size300KB,5 Pages
ManufacturerE-T-A [E-T-A Circuit Breakers]
Download Datasheet Parametric View All

3130-F130-P7T1-W01Q-08A Online Shopping

Suppliers Part Number Price MOQ In stock  
3130-F130-P7T1-W01Q-08A - - View Buy Now

3130-F130-P7T1-W01Q-08A Overview

Circuit Breakers Thermal circuit breaker with rocker actuation, single, double or three pole

3130-F130-P7T1-W01Q-08A Parametric

Parameter NameAttribute value
Product AttributeAttribute Value
ManufacturerE-T-A [E-T-A Circuit Breakers]
Product CategoryCircuit Breakers
RoHSDetails
ProductThermal Circuit Breakers
TypeThermal Overcurrent
Current Rating800 mA
Voltage Rating AC415 VAC
Voltage Rating DC50 VDC
Number of Poles3 Pole
Actuator TypeRocker
Operating Temperature Range- 30 C to + 60 C
IlluminatedNot Illuminated
Height37.5 mm
Length34 mm
Termination StyleBlade
Voltage Rating50 VDC, 415 VAC
Width33 mm
Mounting StyleSnap In
Factory Pack Quantity1
Thermal Overcurrent Circuit Breaker 3130
Description
Single, two and three pole rocker switch/thermal trip free circuit breakers
(S-type TO CBE to EN 60934) of compact design for snap-in panel
mounting. Available either with protection on one/both/all poles or,
in the case of the double pole version, protection on one pole only.
Illumination is optional and there is a choice of rocker colours.
Approved to CBE standard EN 60934 (IEC 60934).
Typical applications
Motors, transformers, solenoids, household and office machines, electrical
tools, mobile homes, boating, construction vehicles, medical equipment
to EN 60601.
1-pole
Standard current ratings and typical internal resistance values
3130
1
3-pole
Technical data
Current
rating (A)
0.1
0.2
0.3
0.4
0.5
0.8
1
1.2
1.5
2
2.5
3
3.5
Internal resistance Current
per pole (Ω)
rating (A)
94
24
12
5.30
4.20
1.50
0.9
0.80
0.45
0.27
0.0785
0.0595
0.0565
4
5
6
7
8
10
12
14
15
16
18
20
Internal resistance
per pole (Ω)
0.0435
0.0325
0.0215
0.0165
0.0165
< 0.02
< 0.02
< 0.02
< 0.02
< 0.02
< 0.02
< 0.02
For further details please see chapter: Technical Information
Voltage rating
AC 240 V; 3 AC 415 V; DC 50 V
(UL: AC 250 V; 3 AC 250 V; DC 50 V)
Current ratings
0.1...20 A 1-pole
0.1...16 A 2- and 3-pole
Typical life
1-pole
AC 240 V: 0.1...20 A 30,000 operations at 1 x I
N
, inductive
DC 50 V:
0.1...4 A
30,000 operations at 1 x I
N
, inductive
4.5...16 A 30,000 operations at 1 x I
N
, resistive
DC 28 V:
0.1...20 A 30,000 operations at 1 x I
N
, inductive
2-pole
AC 240 V: 0.1...16 A 50,000 operations at 1 x I
N
, inductive
DC 50 V:
0.1...16 A 50,000 operations at 1 x I
N
, inductive
3-pole
3 AC 415 V: 0.1...16 A 30,000 operations at 1 x I
N
, inductive
Ambient temperature
-30...+60 °C (-22...+140 °F)
Insulation co-ordination
rated impulse
pollution
(IEC 60664 and 60664 A) withstand voltage
degree
2.5 kV
2
reinforced insulation in operating area
Dielectric strength
(IEC 60664 and 60664A) test voltage
operating area
AC 3,000 V
current path/current path AC 1,500 V
Insulation resistance
> 100 MΩ (DC 500 V)
Interrupting capacity I
cn
0.1...2 A
10 x I
N
2.5...20 A
150 A
1-pole
2.5...16 A
250 A
2-pole
2.5...12 A
150 A
3-pole
14 + 16 A
130 A
3-pole
Interrupting capacity (UL 1077)
I
N
1, 2-pole
3-pole
1,2-pole
Degree of protection
(IEC 60529/DIN 40050)
Vibration
0.1...16 A
0.1...12 A
0.1...16 A
U
N
AC 250 V
3 AC 250 V
DC 50 V
I
nc
3500 A
5000 A
2000 A
Illumination voltage/power consumption
operating voltage
power consumption
1-pole
12 V
24 V
48 V
115 V
230 V
400 V
9 mA
9 mA
9 mA
< 1 mA
< 1 mA
-
2-/3-pole
Y+R
2 mA
2 mA
2 mA
0.9 mA
0.9 mA
0.9 mA
2-/3-pole
G
3.5 mA
3.5 mA
3.5 mA
2.8 mA
2.8 mA
2.8 mA
operating area IP40
terminal area IP00
5 g (57-500 Hz) ± 0.38 mm (10-57 Hz)
to IEC 60068-2-6, test Fc
10 frequency cycles/axis
1-pole: 25 g (11 ms) 2 + 3-pole: 20 g (11 ms)
Shock
Corrosion
Humidity
Mass
to IEC 60068-2-27, test Ea
96 hours at 5 % salt mist,
to IEC 60068-2-11, test Ka
240 hours at 95 % RH,
to IEC 60068-2-78, test Cab
approx. 45 g (three pole)
approx. 31 g (double pole)
approx. 17 g (single pole)
1729
www.e-t-a.de
1
Core points statistics bug? ?
As the title says, I recently found that my core points have not changed. I replied to a few posts and was prompted to add one core point, but the point value in the upper right corner has not changed...
wsmysyn Suggestions & Announcements
[Air Purifier Review] - Honeywell Smart Air Purifier KJ300F-JAC2101W
[align=left][font=微软雅黑]I wanted to buy a water purifier during the Double 11 period. I have been shopping for large household appliances on JD.com. I happened to find that JD.com had a promotion for a...
191033387 DIY/Open Source Hardware
How to perform current detection?
[i=s] This post was last edited by dontium on 2015-1-23 12:40 [/i] I would like to ask all the experts, if I want to detect the current of 4~20ma, what is the appropriate design? The internal resistan...
wstcnsbc1 Analogue and Mixed Signal
Help with MRC p15,0,R0,c0,c0,0
Is the instruction MRC p15,0,R1,c0,c0,0 used to read the ID number of the ARM CPU into the ARM register R1? If so, I have now embedded a .s file with the following assembly content in the EVC environm...
ATT001 Embedded System
What is the use of placing the interrupt flag in the interrupt program?
interrupt[PORT_vector]void PORT1(void){if(P1IFG&BIT0){Delay();if(P1IFG&BIT0){Execution body;P1IFG&=~BIT0;}}}Can this remove jitter? I feel that judging the interrupt flag in the interrupt program can ...
maihy1985 Microcontroller MCU
STM32DAC and PWM clock are not synchronized, please help
I use the internal DAC of the stm32L4 chip to generate a sine wave, and then use the timer's PWM to generate a square wave. However, I found through an oscilloscope that the two waveforms are not sync...
lulongqin12 stm32/stm8

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2523  978  140  78  94  51  20  3  2  13 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号