AC Power Entry Modules w/Fuseholder and Switch 250 VAC 2A
CategoryThe connector   
File Size541KB,6 Pages
ManufacturerSCHURTER
Websitehttp://www.schurterinc.com/
Download Datasheet Parametric Compare View All

43044022 Online Shopping

Suppliers Part Number Price MOQ In stock  
43044022 - - View Buy Now

43044022 Overview

AC Power Entry Modules w/Fuseholder and Switch 250 VAC 2A

43044022 Parametric

Parameter NameAttribute value
Product AttributeAttribute Value
ManufacturerSCHURTER
Product CategoryAC Power Entry Modules
RoHSDetails
ProductInlets
FilteredFiltered
FusedYes
Switch FunctionSwitched
Current Rating2 A
Voltage Rating250 V
Mounting StyleScrew
Termination StyleQuick Connect
Connector TypeIEC-320 C-14
Filter TypeStandard and Medical
Housing MaterialThermoplastic
Flammability RatingUL 94 V-0
Factory Pack Quantity10
Unit Weight4.585615 oz
Power Entry Modules with Line Filter
https://www.schurter.com /PG06
FKI
IEC Appliance Inlet C14 with Filter, Fuseholder 2-pole, Line Switch 2-pole
Aluminum
Nickel plated steel
C14
70° C
Approvals and Compliances
Description
- Panel Mount :
Screw-on mounting from front side
- 4 Functions :
Appliance Inlet Protection class I , Line Switch 2-pole , Fuseholder for
fuse-links 5 x 20 mm 2-pole , Line filter in standard and medical ver-
sion
- Quick connect terminals 6.3 x 0.8 mm
Characteristics
-
-
-
-
-
Compact design with optimal shielding
All single elements are already wired
Plug removal necessary for fuse-link replacement
With EMC-shield
Suitable for use in equipment according to IEC/UL 60950
Suitable for use in medical equipment according to IEC/UL 60601-1
Other versions on request
- Medical version M80
Weblinks
pdf datasheet, html-datasheet, General Product Information, Distributor-
Stock-Check, Accessories, Detailed request for product
Technical Data
Ratings IEC
Ratings UL/CSA
Leakage Current
Dielectric Strength
1 - 10 A @ Ta 40 °C / 250 VAC; 50 Hz
1 - 10 A @ Ta 40 °C / 125 VAC; 60 Hz
standard < 0.25 mA (250 V / 60 Hz)
medical < 5 µA (250 V / 60 Hz)
> 1.7 kVDC between L-N
> 2.7 kVDC between L/N-PE
Test voltage (2 sec)
-25 °C to 85 °C
25/085/21 acc. to IEC 60068-1
from front side IP 40 acc. to IEC 60529
Suitable for appliances with protection
class I acc. to IEC 61140
Quick connect terminals 6.3 x 0.8 mm
Screw: max 8 mm
Mounting screw torque max 0.5 Nm
Thermoplastic, black, UL 94V-0
appliance inlet/-outlet
C14 acc. to IEC 60320-1,
UL 498, CSA C22.2 no. 42 (for cold
conditions) pin-temperature 70 °C, 10 A,
Protection Class I
2-pole, Shocksafe category PC2 acc. to
IEC 60127-6,
for fuse-links 5 x 20 mm
5 x 20: 1.6 W (2-pole)
Admissible power acceptance at higher
ambient temperature see derating cur-
ves
2-pole, non-illuminated, acc. to IEC
61058-1
Technical Details
Standard and Medical Version, IEC
60939, UL 1283, CSA C22.2 no. 8
Technical Details
> 1'700'000 h acc. to MIL-HB-217 F
Fuseholder
Allowable Operation Tempe-
rature
Climatic Category
IP-Protection
Protection Class
Terminal
Panel Thickness S
Material: Housing
Rated Power Acceptance @
Ta 23 °C
Power Acceptance @ Ta >
23°C
Line Switch
Line Filter
MTBF
Approvals and Compliances
Detailed information on product approvals, code requirements, usage instructions and detailed test conditions can be looked up in
Details about
Approvals
Approvals
The approval mark is used by the testing authorities to certify compliance with the safety requirements placed on electronic products.
Approval Reference Type: FKI
Approval Logo
Certificates
VDE Approvals
UL Approvals
Certification Body
VDE
UL
Description
Certificate Number: 40004665
UL File Number: E72928
EMC Products
1

43044022 Related Products

43044022 43044067 43044068 43044070 43044062 43044024 43044069
Description AC Power Entry Modules w/Fuseholder and Switch 250 VAC 2A DC Power Connectors 4P POWER PLUG SNAP AND LOCK AC Power Entry Modules FKI2-50-4/M5 APPLNC INLET FILTER 4A LED Mounting Hardware LED Clip and Ring RWXD Series Black AC Power Entry Modules FKI2-50-2/I-A APPLNC INLET FILTER 2A AC Power Entry Modules w/Fuseholder and Switch 250 VAC 6A AC Power Entry Modules FKI2-50-6/M5 APPLNC INLET FILTER 6A
Manufacturer SCHURTER SCHURTER SCHURTER SCHURTER SCHURTER SCHURTER SCHURTER
Product Category AC Power Entry Modules AC Power Entry Modules AC Power Entry Modules AC Power Entry Modules AC Power Entry Modules AC Power Entry Modules AC Power Entry Modules
Product Inlets Inlets Inlets Inlets Inlets Inlets Inlets
Filtered Filtered Filtered Filtered Filtered Filtered Filtered Filtered
Fused Yes Yes Yes Yes Yes Yes Yes
Switch Function Switched Switched Switched Switched Switched Switched Switched
Factory Pack Quantity 10 10 10 10 10 10 10
Unit Weight 4.585615 oz 4.585615 oz 4.585615 oz 4.585615 oz 4.585615 oz 4.585615 oz 4.585615 oz
Product Attribute Attribute Value - - - Attribute Value Attribute Value Attribute Value
RoHS Details Details Details - - Details Details
TI will have a live broadcast with prizes at 10 am today [MSP430 capacitive touch microcontroller]
[font=微软雅黑][size=3][color=#000000]TI Embedded Processor Theme Month Series Live Broadcast [MSP430 CapTIvate Lite: Cost-Optimized Capacitive Touch Microcontroller] will meet you today! [/color][/size][...
EEWORLD社区 TI Technology Forum
Help, about subwindow creation
I registered the child window class WNDDISPLAY in the initialization of the main window, and the registration was successful. However, when I called hwndChild = CreateWindowEx (WS_EX_CLIENTEDGE, WNDDI...
fdsafsdfsadf Embedded System
Arteli AT32 WB415 Bluetooth function development help
[i=s]This post was last edited by General-P on 2022-9-16 08:45[/i]Arteli AT32 WB415 Bluetooth function development help I want to ask if the Bluetooth of Atria AT32 WB415 can directly send the receive...
General-P RF/Wirelessly
Why does hooking zwTerminateProcess in the file filter driver cause a blue screen?
I want to hook zwTerminateProcess or hook zwOpenProcess in the file filter driver to prevent the specified process from being killed. But when I hook, the system immediately blue screens. But I use th...
何贵君 Embedded System
[DIY Creative LED] Introduction
[i=s]This post was last edited by dcexpert on 2020-9-12 16:22[/i]The original purpose of this creative LED was to help new colleagues quickly master the hardware development process, including circuit...
dcexpert MCU
The buzzer uses C program to set the number of cycles
The following program makes the buzzer ring indefinitely. I want it to ring according to the number of times I set. What should I do? For example, it should stop after ringing 6 times. I am a novice. ...
akpor Embedded System

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1017  2062  2209  2124  1856  21  42  45  43  38 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号