HDC200A160H

Description
Solid State Relays - Industrial Mount PM SSR 150VDC/160A 90-280VAC w/pad
CategoryTopical application    Mechanical and electrical/engineering/automation   
File Size718KB,7 Pages
ManufacturerCrydom
Websitehttp://www.crydom.com/en/index.shtml
Download Datasheet Parametric View All

HDC200A160H Online Shopping

Suppliers Part Number Price MOQ In stock  
HDC200A160H - - View Buy Now

HDC200A160H Overview

Solid State Relays - Industrial Mount PM SSR 150VDC/160A 90-280VAC w/pad

HDC200A160H Parametric

Parameter NameAttribute value
Product AttributeAttribute Value
ManufacturerCrydom
Product CategorySolid State Relays - Industrial Mount
RoHSDetails
Control Voltage Range90 VAC to 140 VAC
Load Voltage Rating7 VDC to 150 VDC
Load Current Rating160 A
Input Current31 mA to 33 mA
Contact FormSPST (1 Form A)
Output TypeSCR
Mounting StylePanel
ProductSSR - Solid State Relays
Termination StyleQuick Connect Terminal
TypeIndicator
Maximum Operating Temperature+ 80 C
Minimum Operating Temperature- 30 C
Factory Pack Quantity1
Unit Weight12 oz
Datasheet
HDC Series
Ratings of 120 A and 160 A @ 48, 72 & 150 VDC
LED Status Indicator
Heavy Duty Stud Terminals
AC or DC control
Micro Seconds Turn-On and Off times
Low On-State Voltage Drop
PWM to 1 kHz for DC Input Models
Panel Mount
PRODUCT SELECTION
Control Voltage
4.5-32 VDC
90-140 VAC
120 A
HDC60D120, HDC100D120, HDC200D120
HDC60A120, HDC100A120, HDC200A120
160 A
HDC60D160, HDC100D160, HDC200D160
HDC60A160, HDC100A160, HDC200A160
AVAILABLE OPTIONS
Series
Control Voltage
A:
90-140 VAC
D:
4.5-32 VDC
Thermal Pad
Blank:
Not Included
H:
Included
HDC
100
A
120
H
Operating Voltage
60:
7-48 VDC
100:
7-72 VDC
200:
7-150 VDC
Required for valid part number
For options only and not required for valid part number
Rated Load Current
120:
120 Amps
160:
160 Amps
OUTPUT SPECIFICATIONS
(1)
Description
HDC60x120
HDC60x160
HDC100x120
HDC100x160
7-72
100
160
160 (≤ 72 VDC)
25 (≤ 72 VDC)
2.5
470
0.15
0.56
0.36
3.5
2/0 / 67.4
225-300 (25.4-33.9)
1000
HDC200x120
7-150
200
120
17 FLA / 2 HP
120 (≤ 150 VDC)
17 (≤ 150 VDC)
2.5
1200
0.2
0.72
0.25
6.0
2/0 / 67.4
225-300 (25.4-33.9)
1000
HDC200x160
7-150
200
160
25 FLA / 3 HP
160 (≤ 150 VDC)
25 (≤ 150 VDC)
2.5
1600
0.2
0.64
0.23
4.0
2/0 / 67.4
225-300 (25.4-33.9)
1000
Operating Voltage [Vdc]
7-48
7-48
7-72
Blocking Voltage [Vdc]
60
60
100
Rated Load Current [A]
(2)
120
160
120
Rated Load Current {UL 508 Motor Controller} [FLA]
Rated Load Current {IEC 60947-4-1 DC-1} [Adc](4,
5)
120 (≤ 48 VDC)
160 (≤ 48 VDC)
120 (≤ 72 VDC)
Rated Load Current {IEC 60947-4-1 DC-3} [FLA](4,
5)
17 (≤ 48 VDC)
25 (≤ 48 VDC)
17 (≤ 72 VDC)
Minimum Load Current [mA]
2.5
2.5
2.5
Maximum Surge Current (10ms) [Adc]
360
470
360
Maximum Off-State Leakage Current @ Rated Voltage [mA]
0.1
0.1
0.15
Maximum On-State Voltage Drop @ Rated Current [VDC]
0.53
0.56
0.52
Thermal Resistance Junction to Case (Rjc) [°C/W]
0.42
0.36
0.42
Maximum On-State Resistance @ Rated Current (RDS-ON) [mOhms]
4.32
3.5
4.32
Wire Size max (solid/stranded) [AWG/ IEC mm²]
2/0 / 67.4
2/0 / 67.4
2/0 / 67.4
Output Terminal Nut Torque Range [in lb (Nm)
225-300 (25.4-33.9) 225-300 (25.4-33.9) 225-300 (25.4-33.9)
Maximum PWM (Hz)
(3)
1000
1000
1000
INPUT SPECIFICATIONS
(1)
Description
Control Voltage Range
Must Turn-Off Voltage
Minimum Input Current @ Minimum Voltage (for on-state)
Maximum Input Current @ Maximum Voltage
Nominal Input Impedance
Maximum Turn-On Time at min voltage
Maximum Turn-On Time at max voltage
Maximum Turn-Off Time at min voltage
Maximum Turn-Off Time at max voltage
Terminal Type / size in (mm)
HDC60D & HDC100D
4.5-32 VDC
4.2 VDC
23 mA
45 mA
Current Regulated
90.5 µs
8.5 µs
145 µs
330 µs
QC / 0.187 (4.75)
HDC60A & HDC100A
90-140 VAC
35 VAC
31 mA
33 mA
Current Regulated
6 ms
4 ms
9.2 ms
9.2 ms
QC / 0.187 (4.75)
HDC200D
4.5-32 VDC
4.2 VDC
23 mA
45 mA
Current Regulated
92 µs
12.0 µs
195 µs
405 µs
QC / 0.187 (4.75)
HDC200A
90-140 VAC
35 VAC
31 mA
33 mA
Current Regulated
6 ms
4 ms
9.2 ms
9.2 ms
QC / 0.187 (4.75)
Do not forget to visit us at:
www.crydom.com
Copyright © 2016 Crydom Inc. Specifications subject to change without notice.
stc information
Everyone take a look...
fhyfm DIY/Open Source Hardware
Ask for answers
How to set rules for a Room (an area) in AD? Please help me answer (vias, line spacing, line width)...
小不懂886 PCB Design
2440 Learning Record (V) Writing Character Drivers with Interrupts
[i=s]This post was last edited by lonerzf on 2014-7-21 15:21[/i] [align=left]Reference article: blog.csdn.net/lwj103862095/article/details/17511867[/align][align=left] [font=宋体]hi.baidu.com/513773348/...
lonerzf Linux and Android
USB to RS422/485 enable terminal switching problem
I recently worked on the USB CDC of PIC32 to realize the USB to TTL conversion. Now I plan to expand it and use two MAX485 to realize the USB to RS422/485 function. But now I am confused about how to ...
电子微创意 Microchip MCU
C language implementation of control method
Original work, shared with everyone....
longtend TI Technology Forum
The XOZ gain graph seems wrong, why?
I simulated an antenna using 18.1. From the 3D diagram, it should be omnidirectional on the XOZ plane. But the diagram drawn by the software seems strange. What is the problem? 3D diagram and XOZ diag...
flyingwave RF/Wirelessly

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2530  2432  212  1593  1706  51  49  5  33  35 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号