Part Number

Search

V-15G5-1A5-K

Description
Basic / Snap Action Switches MINIATURE BASIC SWITCH
CategoryMechanical and electronic products    switch   
File Size665KB,8 Pages
ManufacturerOMRON
Websitehttps://www.omron.com
Environmental Compliance
Download Datasheet Parametric View All

V-15G5-1A5-K Online Shopping

Suppliers Part Number Price MOQ In stock  
V-15G5-1A5-K - - View Buy Now

V-15G5-1A5-K Overview

Basic / Snap Action Switches MINIATURE BASIC SWITCH

V-15G5-1A5-K Parametric

Parameter NameAttribute value
Is it lead-free?Lead free
Is it Rohs certified?conform to
MakerOMRON
package instructionROHS COMPLIANT
Reach Compliance Codeunknown
ECCN codeEAR99
Factory Lead Time14 weeks
Actuator stroke2.5 mm
Actuator typeSHORT HINGE ROLLER LEVER
body width10.3 mm
body height15.9 mm
Body length or diameter27.8 mm
Contact (AC) maximum rated R load15A@250VAC
Maximum contact current (AC)15 A
Maximum contact current (DC)15 A
Contact (DC) maximum rated R load15A@8VDC
Maximum contact voltage (AC)250 V
Maximum contact voltage (DC)8 V
Electrical life100000 Cycle(s)
Manufacturer's serial numberV
Installation featuresPANEL MOUNT
Maximum operating force1.96 N
Maximum operating temperature80 °C
Minimum operating temperature-25 °C
Maximum pre-travel1.5 mm
sealIP40
surface mountNO
Switch actionMOMENTARY
switch functionSPDT
Switch typeSNAP ACTING/LIMIT SWITCH
Termination typeSOLDER
Subminiature Basic Switch
SSG
Global Subminiature Basic Switch
Conforming to EN, UL, and CSA Standards
• A wide operating temperature range of -25°C to 125°C is
available for at high-temperature use.
• PCB terminal models are resistant to flux.
• Even-pitched PCB terminals.
• Mounting hole size of M2.2.
• RoHS Compliant.
Ordering Information
Actuator
Pin plunger
5A
0.1 A
Hinge lever
5A
0.1 A
Simulated roller lever
5A
0.1 A
Hinge roller lever
5A
0.1 A
Rating
OF max.
153 gf
51 gf
153 gf
51 gf
61 gf
20 gf
61 gf
20 gf
61 gf
20 gf
61 gf
20 gf
61 gf
20 gf
61 gf
20 gf
Solder
SSG-5H
SSG-5H-5
SSG-01H
SSG-01H-5
SSG-5L1H
SSG-5L1H-5
SSG-01L1H
SSG-01L1H-5
SSG-5L3H
SSG-5L3H-5
SSG-01L3H
SSG-01L3H-5
SSG-5L2H
SSG-5L2H-5
SSG-01L2H
SSG-01L2H-5
Quick-connect
terminal (#110)
SSG-5T
SSG-5T-5
SSG-01T
SSG-01T-5
SSG-5L1T
SSG-5L1T-5
SSG-01L1T
SSG-01L1T-5
SSG-5L3T
SSG-5L3T-5
SSG-01L3T
SSG-01L3T-5
SSG-5L2T
SSG-5L2T-5
SSG-01L2T
SSG-01L2T-5
PCB
SSG-5P
SSG-5P-5
SSG-01P
SSG-01P-5
SSG-5L1P
SSG-5L1P-5
SSG-01L1P
SSG-01L1P-5
SSG-5L3P
SSG-5L3P-5
SSG-01L3P
SSG-01L3P-5
SSG-5L2P
SSG-5L2P-5
SSG-01L2P
SSG-01L2P-5
Note:
SPST models are also available, but not listed in the above table.
Model Number Legend
SSG-
1 2 3 4 5
1.
Ratings
5:
5 A at 125 VAC
01:
0.1 A at 125 VAC
Actuator
None: Pin plunger
L1:
Hinge lever
L2:
Hinge roller lever
L3:
Simulated roller lever
3.
Contact Form
None: SPDT
-2:
SPST-NC
-3:
SPST-NO
5.
Maximum Operating Force
(see note)
None: 153 gf
-5:
51 gf
Note:
These OF
values
are for the pin plunger models.
2.
4.
Terminals
H:
Solder terminals
T:
Quick-connect terminals (#110)
P:
PCB terminals (SPDT only)
Consult Omron regarding the following:
- SPST-NC and SPST-NO
versions
(Solder and QC terminals, only)
Subminiature Basic Switch
SSG
109
Ask for guidance from seniors
I am engaged in network technology and MB testing. Now I need to learn some basic knowledge of electronic circuits. I need detailed explanations. If you have any good information, please upload it. I ...
viqptf Analog electronics
What tools are needed for reflow soldering?
Existing tools: infrared radiation and hot air mixed SMT lead-free reflow furnace. I think I need steel mesh, scraper, solder paste. [b] Red glue is too complicated, is it okay? Do I need a carrier bo...
大发明家 PCB Design
ATK-0.96' OLED module
ATK-0.96' OLED module complete set of information, including schematics and source code. I have tested and debugged it myself, and it can be called directly.#include "oled.h"#include "stdlib.h"#includ...
jiminhe Test/Measurement
Some questions about impedance or admittance characteristic curve
In general, the characteristic curve of the transducer is the impedance characteristic curve composed of R and X, or the admittance characteristic curve composed of G and B. But now the curve of my tr...
shaorc Integrated technical exchanges
It's urgent. Why do I keep getting errors when I assign the dial code to the program?
Arbitrary integer division, duty cycle is 50% (VHDL) --Hope it can help you--******************************************-- --Program name: Arbitrary integer division, duty cycle is 50% --**************...
pyy1980 FPGA/CPLD
Capture mode of timer A
msp430f5529lp sets TIMER A to capture mode and captures the rising edge. Does this have any requirements for the port input voltage? I have a board that can only output about 1.45V voltage. I want to ...
jianhong0425 MCU

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 243  2134  1699  261  1305  5  43  35  6  27 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号