EEWORLDEEWORLDEEWORLD

Part Number

Search

LUCD1XB

Description
Motor Drives ADV CNTRL UNIT CL20 3PH .3-1.4A 24V
CategoryTopical application    Mechanical and electrical/engineering/automation   
File Size53KB,2 Pages
ManufacturerSCHNEIDER ELECTRIC
Download Datasheet Parametric View All

LUCD1XB Online Shopping

Suppliers Part Number Price MOQ In stock  
LUCD1XB - - View Buy Now

LUCD1XB Overview

Motor Drives ADV CNTRL UNIT CL20 3PH .3-1.4A 24V

LUCD1XB Parametric

Parameter NameAttribute value
Product AttributeAttribute Value
ManufacturerSCHNEIDER ELECTRIC
Product CategoryMotor Drives
Factory Pack Quantity1
Product data sheet
Characteristics
LUCD1XB
advanced control unit LUCD - class 20 -
0.35...1.4 A - 24 V AC
Main
Range of product
Device short name
Product or component
type
Product specific appli-
cation
Product compatibility
TeSys U
LUCD
Advanced control unit
Basic protection and advanced functions, communi-
cation
ASILUFC5
ASILUFC51
LUFC00
LUFDA01
LUFDA10
LUFDH11
LUFN..
LUFV2
LUFW10
LULC031
LULC033
LULC07
LULC08
LULC09
LULC15
AC-41
AC-43
AC-44
0.25 kW at 400...440 V AC 50/60 Hz
0.35...1.4 A
24 V AC
Class 20 - frequency limit: 40...60 Hz - tempera-
ture compensation: -25...70 °C - conforming to IEC
60947-6-2
Class 20 - frequency limit: 40...60 Hz - temperature
compensation: -25...70 °C - conforming to UL 508
Utilisation category
Motor power kW
Thermal protection ad-
justment range
[Uc] control circuit volt-
age
Overload tripping class
Complementary
Main function available
Earth fault protection
Manual reset
Protection against overload and short-circuit
Protection against phase failure and phase imbalance
Plug-in
Front side
20...26.5 V for AC circuit 24 V in operation
140 mA at 24 V AC I maximum while closing with LUB12
220 mA at 24 V AC I maximum while closing with LUB32
70 mA at 24 V AC I rms sealed with LUB12
90 mA at 24 V AC I rms sealed with LUB32
35 ms opening with LUB12 for control circuit
35 ms opening with LUB32 for control circuit
70 ms closing with LUB12 for control circuit
70 ms closing with LUB32 for control circuit
3-phase motor - cooling: self-cooled
14.2 x Ir +/- 20 %
600 V conforming to CSA 22-2 No 14
600 V conforming to UL 508
690 V conforming to IEC 60947-1
6 kV conforming to IEC 60947-6-2
Mounting mode
Mounting location
Control circuit voltage limits
Typical current consumption
Operating time
Load type
Tripping threshold
[Ui] rated insulation voltage
[Uimp] rated impulse withstand voltage
Feb 20, 2018
1
The information provided in this documentation contains general descriptions and/or technical characteristics of the performance of the products contained herein.
This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications.
It is the duty of any such user or integrator to perform the appropriate and complete risk analysis, evaluation and testing of the products with respect to the relevant specific application or use thereof.
Neither Schneider Electric Industries SAS nor any of its affiliates or subsidiaries shall be responsible or liable for misuse of the information contained herein.
Live broadcast at 10:00 am today [Unlocking new possibilities of TI Sitara AM2x MCU in motor drive]
This seminar will introduce TI's latest AM243x high-performance MCU, which solves the performance gap between flash-based MCUs and processors; it will also introduce how the Sitara AM243x MCU portfoli...
EEWORLD社区 Microcontroller MCU
Use protel99 to design logic circuits.asp
Use protel99 to design logic circuits.asp...
fighting PCB Design
Save parameters to FLASH
Moderator: HelloIn the SegmentA information storage area of MSP430F149, can it be provided to users as parameters? I want to store the modified parameters in FLASH. Do you have a FLASH erase and write...
toutou13 Microcontroller MCU
Reading notes
[color=#000][font=Helvetica, Arial, sans-serif]I wonder if you have read the book 'MCU Engineer's Refining Record'. I just read the third chapter, which is the beginning of the text, and I can't stand...
zhangya0916 Microcontroller MCU
CCS+C6678LE Development Record 18: Solve the problem of "DHCP configuration cannot obtain IP" on the EVM network port
The following problems were encountered during the previous test: When the DSP's network IP configuration is set to DHCP mode, an error will occur and the IP address cannot be obtained. The printed in...
fish001 DSP and ARM Processors
Which version of ccs supports g2553? ? ? Ask for a cracked version
Which version of ccs supports g2553? ? ? I want a cracked version for beginners...
jetlin1992 Microcontroller MCU

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1508  1442  1600  704  1941  31  30  33  15  40 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号