Stresses beyond those listed under “Absolute Maximum Ratings” may cause permanent damage to the device. These are stress ratings only, and functional operation of the device at these
or any other conditions beyond those indicated in the operational sections of the specifications is not implied. Exposure to absolute maximum rating conditions for extended periods may affect
device reliability.
Electrical Characteristics
(V
BATT
= 1.2V, V
OUT
= 3.3V (MAX1722/MAX1723), V
OUT
= V
OUT(NOM)
(MAX1724),
SHDN
= OUT, R
L
= ∞,
T
A
= 0°C to +85°C,
unless otherwise noted. Typical values are at T
A
= +25°C.) (Note 1)
PARAMETER
Minimum Input Voltage
Operating Input Voltage
Minimum Start-Up Input Voltage
V
IN
SYMBOL
T
A
= +25°C
T
A
= +25°C,
R
L
= 3kΩ
MAX1724E__27
MAX1724E__30
Output Voltage
V
OUT
MAX1724E__33
MAX1724E__50
Output Voltage Range
Feedback Voltage
Feedback Bias Current
N-Channel On-Resistance
P-Channel On-Resistance
N-Channel Switch Current Limit
Switch Maximum On-Time
Synchronous Rectifier Zero-
Crossing Current
Quiescent Current into OUT
Shutdown Current into OUT
Quiescent Current into BATT
V
OUT
V
FB
I
FB
R
DS(ON)
R
DS(ON)
I
LIM
t
ON
MAX1722/MAX1723
MAX1722/MAX1723
MAX1722/MAX1723
V
OUT
forced to 3.3V
V
OUT
forced to 3.3V
V
OUT
forced to 3.3V
V
OUT
forced to 3.3V
(Notes 3, 4)
MAX1723/MAX1724
(Notes 3, 4)
MAX1722/MAX1724
(Note 4)
T
A
= +85°C
T
A
= +25°C
T
A
= +85°C
T
A
= +25°C
CONDITIONS
MAX1722/MAX1724
MAX1722/MAX1724
MAX1723 (Note 2)
MAX1722/MAX1724
MAX1723 (Note 2)
T
A
= +25°C
T
A
= +25°C
T
A
= +25°C
T
A
= +25°C
2.673
2.633
2.970
2.925
3.267
3.218
4.950
4.875
2
1.223
1.210
1.5
2.2
0.5
1.0
400
3.5
5
500
5
20
1.5
0.01
0.1
0.001
0.01
0.5
1.0
2.0
600
6.5
35
3.6
0.5
1.235
5.0
3.3
3.0
T
A
= 0°C to +85°C
T
A
= 0°C to +85°C
T
A
= 0°C to +85°C
T
A
= 0°C to +85°C
0.91
1.2
0.83
0.87
2.7
MIN
TYP
0.8
5.5
5.5
0.91
1.2
2.727
2.767
3.030
3.075
3.333
3.383
5.050
5.125
5.5
1.247
1.260
20
V
V
nA
Ω
Ω
mA
µs
mA
µA
µA
µA
V
MAX
UNITS
V
V
V
T
A
= +25°C
T
A
= +25°C
T
A
= 0°C to +85°C
T
A
= +85°C
www.maximintegrated.com
Maxim Integrated
│
2
MAX1722/MAX1723/
MAX1724
Electrical Characteristics (continued)
1.5μA I
Q
, Step-Up DC-DC
Converters in TSOT and µDFN
(V
BATT
= 1.2V, V
OUT
= 3.3V (MAX1722/MAX1723), V
OUT
= V
OUT(NOM)
(MAX1724),
SHDN
= OUT, R
L
= ∞,
T
A
= 0°C to +85°C,
unless otherwise noted. Typical values are at T
A
= +25°C.) (Note 1)
PARAMETER
Shutdown Current into BATT
SHDN
Voltage Threshold
SHDN
Input Bias Current
V
IH
V
IL
SYMBOL
CONDITIONS
MAX1724 (Note 4)
MAX1723/MAX1724
MAX1723/MAX1724
MAX1723/MAX1724,
V
SHDN
= 5.5V
T
A
= +85°C
T
A
= +25°C
T
A
= +25°C
T
A
= +85°C
75
MIN
TYP
0.001
0.01
400
500
2
7
800
100
MAX
0.5
UNITS
µA
mV
nA
Electrical Characteristics
(V
BATT
= 1.2V, V
OUT
= 3.3V (MAX1722/MAX1723), V
OUT
= V
OUT(NOM)
(MAX1724),
SHDN
= OUT, R
L
= ∞, T
A
= -40°C to +85°C,
unless otherwise noted.) (Note 1)
PARAMETER
Output Voltage
Output Voltage Range
Feedback Voltage
N-Channel On-Resistance
P-Channel On-Resistance
N-Channel Switch Current Limit
Switch Maximum On-Time
Synchronous Rectifier Zero-
Crossing Current
Quiescent Current into OUT
SHDN
Voltage Threshold
V
IH
V
IL
SYMBOL
V
OUT
V
OUT
R
DS(ON)
R
DS(ON)
I
LIM
t
ON
V
FB
CONDITIONS
MAX1724E__27
MAX1724E__30
MAX1724E__33
MAX1724E__50
MAX1722/MAX1723
MAX1722/MAX1723
V
OUT
forced to 3.3V
V
OUT
forced to 3.3V
V
OUT
forced to 3.3V
V
OUT
forced to 3.3V
(Notes 3,4)
MAX1723/MAX1724
MAX1723/MAX1724
75
800
400
3.5
5
MIN
2.633
2.925
3.218
4.875
2
1.200
TYP
MAX
2.767
3.075
3.383
5.125
5.5
1.270
1.0
2.0
620
6.5
35
3.6
V
V
Ω
Ω
mA
µs
mA
µA
mV
V
UNITS
Note 1:
Limits are 100% production tested at T
A
= +25°C. Limits over the operating temperature range are guaranteed by design.
Note 2:
Guaranteed with the addition of a Schottky MBR0520L external diode between LX and OUT when using the MAX1723 with
only one cell, and assumes a 0.3V voltage drop across the Schottky diode (see Figure 3).
Note 3:
Supply current is measured with an ammeter between the output and OUT pin. This current correlates directly with actual
battery supply current, but is reduced in value according to the step-up ratio and efficiency.
Note 4:
V
OUT
forced to the following conditions to inhibit switching: V
OUT
= 1.05 x V
OUT(NOM)
(MAX1724), V
OUT
= 3.465V
(MAX1722/MAX1723).
www.maximintegrated.com
Maxim Integrated
│
3
MAX1722/MAX1723/
MAX1724
Typical Operating Characteristics
1.5μA I
Q
, Step-Up DC-DC
Converters in TSOT and µDFN
(Figure 3 (MAX1723), Figure 7 (MAX1722), Figure 8 (MAX1724), V
BATT
= V
IN
= 1.5V, L = 10μH, C
IN
= 10μF, C
OUT
= 10μF, T
A
= +25°C,
unless otherwise noted.)
EFFICIENCY vs. LOAD CURRENT
(V
OUT
= 5.0V)
MAX1722 toc01
MAX1722 toc02
90
EFFICIENCY (%)
80
70
60
V
IN
= 2.0V
V
IN
= 3.3V
V
IN
= 4.0V
90
EFFICIENCY (%)
80
70
60
50
V
IN
= 2.0V
V
IN
= 2.5V
90
EFFICIENCY (%)
80
70
60
50
V
IN
= 1.0V
0.01
0.1
1
10
L = DO1606
100
V
IN
= 2.0V
V
IN
= 1.5V
V
IN
= 1.0V
V
IN
= 1.5V
L = DO1606
10
100
1000
V
IN
= 1.0V
V
IN
= 1.5V
0.01
0.1
1
10
L = DO1606
100
1000
50
0.01
0.1
1
1000
LOAD CURRENT (mA)
LOAD CURRENT (mA)
LOAD CURRENT (mA)
MAXIMUM OUTPUT CURRENT
vs. INPUT VOLTAGE
MAX1722 toc04
MAX1722 toc05
QUIESCENT CURRENT (µA)
STARTUP VOLTAGE (V)
160
I
OUT(MAX)
(mA)
120
80
V
OUT
= 2.5V
2.2
2.0
1.8
1.6
1.4
1.2
1.0
0.8
RESISTIVE LOAD
V
OUT
= 5.0V
1.8
1.6
1.4
1.2
1.0
0.8
0.6
0.4
0.2
0
NO LOAD
V
OUT
= 5.0V
V
OUT
= 3.3V
40
0
0
1
2
3
4
5
0.6
0.01
0.1
INPUT VOLTAGE (V)
10
LOAD CURRENT (mA)
1
100
1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 5.5
OUTPUT VOLTAGE (V)
STARTUP VOLTAGE vs.
TEMPERATURE
NO LOAD
MAX1722 toc07
SWITCHING WAVEFORMS
MAX1722 toc08
1.2
1.0
STARTUP VOLTAGE (V)
0.8
0.6
0.4
0.2
0
I
LX
500mA/div
V
OUT
50mV/div
V
LX
2V/div
-40
-15
10
35
60
85
TEMPERATURE (°C)
1µs/div
I
OUT
= 50mA, V
OUT
= 5.0V, V
IN
= 3.3V
www.maximintegrated.com
Maxim Integrated
│
4
MAX1722 toc06
200
2.4
STARTUP VOLTAGE
vs. LOAD CURRENT
2.0
QUIESCENT CURRENT INTO OUT
vs. OUTPUT VOLTAGE
MAX1722 toc03
100
100
EFFICIENCY vs. LOAD CURRENT
(V
OUT
= 3.3V)
100
EFFICIENCY vs. LOAD CURRENT
(V
OUT
= 2.5V)
MAX1722/MAX1723/
MAX1724
Typical Operating Characteristics (continued)
1.5μA I
Q
, Step-Up DC-DC
Converters in TSOT and µDFN
(Figure 3 (MAX1723), Figure 7 (MAX1722), Figure 8 (MAX1724), V
As the title says! After the ADC is started, the DMA automatically transfers the data to a set array (or variable) after the conversion is completed!...
What is the solution for converting DC12V to DC1000V? Does anyone have any solution? The output power of 1000V is very low, no more than 2w, and it is powered by a 12V battery. I don't know if it can ...
Topic 1 : DC regulated power supplyIndependently complete the design of a DC regulated power supply.
The technical indicator requirements are as follows:1.Input AC voltage is 50Hz , 220V ;
2.The outpu...
Reposted from Ingrid Zhang's blog Aries: This is the sign that dominates anger and sexual energy. They will get angry when they are not satisfied. They will vent their anger. Their anger comes and goe...
The compilation we usually do is called local compilation, which means compiling on the current platform, and the compiled program is also executed locally. Relatively speaking, cross compilation refe...
1. Overview
Will passive devices
produce nonlinear intermodulation distortion? The answer is yes! Although there is no systematic theoretical analysis, it has been found in engineerin...[Details]
In public places such as schools, government agencies, factories and mines, as well as public corridors in residential areas, the phenomenon of long-burning lights is very common, which causes a h...[Details]
This paper designs a dot matrix LED text display screen that is easy to update, expandable, and low-cost. The way to reduce costs is
① Use the Bluetooth data transmission function of mobile ph...[Details]
When choosing a laptop battery, you should consider several factors, such as power, appearance, and quality.
Regarding power, we often see that a manufacturer uses values such as the number ...[Details]
PV inverter manufacturer SMA has launched its first DC arc fault circuit interrupter (AFCI) PV inverter and has received UL certification.
The new SunnyBoy AFCI inverter models include 3000-US...[Details]
12v Lead Acid batteries used in trucks, cars, RVs and uninterruptible power supplies are usually rated at 12V. This circuit monitors the battery, the charge and discharge curves, gives the cu...[Details]
Spatial Division Multiplexing (SDM) MIMO processing can significantly improve spectrum efficiency and thus greatly increase the capacity of wireless communication systems. Spatial Division Multip...[Details]
LED light sources have many environmental advantages, but early products still have certain technical bottlenecks in heat dissipation and high brightness design that cannot be broken through....[Details]
Since the late 1990s, with the demand for higher system efficiency and lower power consumption, the technological update of telecommunications and data communication equipment has promoted the deve...[Details]
Analysis of the three core aspects of digital TV transmission standards
According to the differences in regionality, transmission method and modulation method, the transmission method needs to...[Details]
introduction
Steam turbines are driven by high-temperature and high-pressure steam generated by boilers to run at high speed. They are key power equipment in thermal power plants. The emergenc...[Details]
0 Introduction
In order to improve the automation control of shortwave transmitters, so that they can automatically process from far to near, the technicians here use the ICS system to complete the ...[Details]
1 What is an LED floodlight?
LED downlights are also called spotlights, projection lamps, and spotlights. They are mainly used for architectural decorative lighting and commercial space lighti...[Details]
As the global LED market demand continues to increase, my country's LED industry will face huge opportunities in the future. However, the core LED technology and patents are basically monopolized b...[Details]
Rated capacity refers to the maximum output power of the UPS (the product of voltage V and current A).
Usually, the UPS power supplies sold on the market are marked with "W" (watt) for smaller...[Details]