EEWORLDEEWORLDEEWORLD

Part Number

Search

3000-04500019

Description
Thermostats PRECISION THERMAL
CategoryThe sensor   
File Size211KB,2 Pages
ManufacturerHoneywell
Websitehttp://www.ssec.honeywell.com/
Download Datasheet Parametric View All

3000-04500019 Online Shopping

Suppliers Part Number Price MOQ In stock  
3000-04500019 - - View Buy Now

3000-04500019 Overview

Thermostats PRECISION THERMAL

3000-04500019 Parametric

Parameter NameAttribute value
Product AttributeAttribute Value
ManufacturerHoneywell
Product CategoryThermostats
FunctionClose on Rise
Temperature Range- 29 C to + 260 C
ProductVehicle Fire Suppression Thermostats
Factory Pack Quantity10
TRANSPORTATION APPLICATIONS
Application Note
3000 Series Thermostats in Vehicle Fire Suppression
Applications
BACKGROUND
A fire resulting from a vehicle collision may lead to death
because it becomes impossible to escape the burning vehicle.
An effective fire suppression system helps to reduce fatalities
in these situations.
SOLUTION
Honeywell manufactures the 3000 Series Thermostats (see
Table 1), a range of rugged, sealed thermostats, that signal
when a certain temperature has been reached. In an automatic
fire suppression system, the thermostat signals the system to
discharge in the event of a fire.
Table 1. 3000 Series Vehicle Fire Suppression Thermostat
3000 Series Vehicle Fire Suppression Thermostat
When the thermostat ambient temperature reaches the rated
temperature, the switch contacts close, completing the
electrical circuit which triggers the system actuator. When the
thermostat cools, the contacts reopen, which resets the
thermostat to its normal operation condition.
At least one thermostat is installed in each protected area of
the vehicle (see Figure 1). The four-conductor configuration
allows continuous integrity monitoring of all circuits connecting
the thermostats.
Features and Benefits
Stainless steel housing provides enhanced resistance to corrosion and harsh, under-the-hood chemicals
Sealed construction designed to prevent water ingress
Configurable operating point may be tailored to application requirements up to 232
°C
[450
°F]
Enhanced response for reduced deployment time
Enhanced reliability for potentially maintenance-free operation
Flexible mounting bracket allows multiple installation sites for the same product
Figure 1. Fire Suppression System Block Diagram
Sensing and Control
About the emulator problem
Can EZ430-F2013 simulate MSP430F4152?I can't find the device when I connect vcc, test, rst, gnd for simulation...
pcyk808686 Microcontroller MCU
stm32 USB implements U disk dead loop
[size=14px]Today, I found a problem when debugging the USB of stm32. The USB can communicate with the computer normally. But the problem is that before connecting to the computer, after the USB is ena...
hyhstephen stm32/stm8
I need help with the problem of using dtc of adc10 in 2274. I have many questions. I hope you can give me some advice.
I'm using 2274's adc10 sampling recently. When using the dtc function, I found that it doesn't sample and doesn't interrupt. I hope you can give me some advice:My source code:#include "msp430x22x4.h"i...
elton0296 Microcontroller MCU
TOS RPTC
When I was debugging a program, I found that there are two registers in the CPU registers , TOS and RPTC. I don't knowwhat they are for. Of course, there are also ACC, PREG, TREG, butI know all of the...
redlark Analogue and Mixed Signal
How to access the mobile phone font library???
How to enter the mobile phone font modification program, is there any program or something else needed???...
updowncreay Embedded System
A design of electromagnetic compatibility protection for power supply
The electromagnetic compatibility protection design should adopt a comprehensive approach to systematically predict the electromagnetic compatibility of arc welding equipment. When designing, the prod...
zbz0529 Power technology

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2312  1779  1088  1654  318  47  36  22  34  7 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号