EEWORLDEEWORLDEEWORLD

Part Number

Search

CJ2-B2-26-670-33J-D

Description
Circuit Breakers SPDT 50/60 HZ LONG
CategoryCircuit protection   
File Size3MB,26 Pages
ManufacturerCarling Technologies
Download Datasheet Parametric View All

CJ2-B2-26-670-33J-D Online Shopping

Suppliers Part Number Price MOQ In stock  
CJ2-B2-26-670-33J-D - - View Buy Now

CJ2-B2-26-670-33J-D Overview

Circuit Breakers SPDT 50/60 HZ LONG

CJ2-B2-26-670-33J-D Parametric

Parameter NameAttribute value
Product AttributeAttribute Value
ManufacturerCarling Technologies
Product CategoryCircuit Breakers
RoHSDetails
ProductHydraulic Magnetic Circuit Breakers
TypeSupplementary Protector / Motor Controller
Current Rating70 A
Voltage Rating AC277 VAC
Voltage Rating DC80 VDC
Number of Poles2 Pole
Actuator TypeRocker
Operating Temperature Range- 40 C to + 85 C
IlluminatedNot Illuminated
Termination StyleThreaded Stud
Mounting StylePanel
Factory Pack Quantity10
Unit Weight8 oz
C-Series
C-Series
CIRCUIT BREAKER
The C-Series hydraulic-magnetic circuit breakers are ideal for applications that require higher amperage and
voltage handling capability in a smaller package. They are available in 1-6 poles, 0.02-100amps, UL Recognized
up to 480VAC or 150VDC, UL489 Listed up to 240VAC or 125VDC, with choice of time delays, terminal
options, actuator styles and colors. The C-Series employs a unique arc chute design which allows for higher
interrupting capacities of up to 10,000 amps. Thermoset glass filled polyester half shell construction provides
for increased mechanical and electrical strength. The wiping contacts mechanical linkage, with two step
actuation, cleans contacts providing high, positive contact pressure and longer contact life. Available with
American Standard or Metric Threaded Stud terminals, or Saddle Clamp screw terminals. The optional mid-trip
handle style actuator allows a visual indication of electrical overload with or without alarm feature.
Product Highlights:
Š
Š
Š
Š
Š
Š
Š
Extensive list of Agency Approvals
Available with Standard or Metric Stud terminals,
or Saddle Clamp screw terminals
Optional mid-trip handle style actuator
Unique arc chute design which allows for higher
interrupting capacities of up to 10,000 amps
Exclusive Rockerguard and Push-To-Reset bezel
Available with new solid color and two-color Visi-
rocker® actuators
New thermoset glass filled polyester half shell
construction
Typical Applications:
Š
Š
Š
Š
Š
Marine
Telecom/Datacom
Military
Renewable Energy
Generators & Welders
Carling Technologies, Inc.
60 Johnson Avenue, Plainville, CT
06062
Email:
sales
@
carlingtech.com
Application Support:
team2
@
carlingtech.com
Phone:
860.793.9281
Fax:
860.793.9231
www.carlingtech.com
Newbie urgent help…How to use STC series to generate frequency adjustable square wave? ????? ????? ????
[size=5][color=red]The microcontroller model is STC 12C5A60S2. How can I program it to output a 4KHz-5KHz square wave with an amplitude of 1V and variable frequency? The 4X4 button requires that after...
ejobs 51mcu
LM Flash programmer cannot be used after installation
After downloading and installing TI's programmer software, click the icon to run it, and the "0xxxxxxxxxxx" instruction references the "0x0xxxxxxxxx" memory, which cannot be read.In this case, you can...
colarence Microcontroller MCU
The schematic diagram is correct but the result is wrong. Please help me.
As the title says, the schematic and rule check are correct, but the production PCB has many wires that are not connected. Can I connect them myself?...
freeNathaniel PCB Design
Notice on organizing the 2009 National Undergraduate Electronic Design Competition
[i=s]This post was last edited by paulhyde on 2014-9-15 09:35[/i][size=4][b][color=red]Introduction:[/color][/b]The National Undergraduate Electronic Design Competition (2009-2012) Organizing Committe...
open82977352 Electronics Design Contest
How to use synplify to synthesize a project with a core generator to generate IP?
I used synplify to synthesize a project with an ISE IP core, added properties to make it a black box, and when I checked it in synplify, it was successfully synthesized as a black box, as shown in the...
eeleader FPGA/CPLD
Please help me find where is the error in this code
module example1(equal); output equal; reg a,b; reg equal; initial begin a=0; b=0;#100 a=0;b=1; #100 b=1;b=1; #100 a=1;b=0; #100 $stop; end compare compare1(equal,a,b); endmodule module compare(equal,a...
瓷娃娃 FPGA/CPLD

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1620  1165  2607  2611  2678  33  24  53  54  36 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号