EEWORLDEEWORLDEEWORLD

Part Number

Search

A8GSC1115

Description
Rocker Switches Remote Reset DPST Micro+Pwr Solder No
CategoryTopical application    Mechanical and electrical/engineering/automation   
File Size2MB,8 Pages
ManufacturerOMRON
Websitehttps://www.omron.com
Download Datasheet Parametric View All

A8GSC1115 Online Shopping

Suppliers Part Number Price MOQ In stock  
A8GSC1115 - - View Buy Now

A8GSC1115 Overview

Rocker Switches Remote Reset DPST Micro+Pwr Solder No

A8GSC1115 Parametric

Parameter NameAttribute value
Product AttributeAttribute Value
ManufacturerOMRON
Product CategoryRocker Switches
RoHSDetails
Contact FormDPST
Switch FunctionON - OFF
Current Rating16 A, 10 A
Voltage Rating AC125 VAC, 250 VAC
Termination StyleSolder Pin
ActuatorRocker
ColorBlack
Mounting StyleThrough Hole
Terminal SealUnsealed
Contact PlatingSilver
Contact Rating200 mA at 5 VDC
Operating Temperature Range- 10 C to + 55 C
Factory Pack Quantity50
Unit Weight0.352740 oz
New Product
Remote Reset Rocker Switch
A8GS
Minimum size class in the industry Rocker switch with reset function
• Zero standby power by Reset function.
• High inrush-current durability.
Conforming to TV-8 rating. (Inrush 117A)
• Model variation for Micro loads.
• Model variation of micro load and high capacity combination. (DPST)
It is able to operate micro load and high capacity load at the same time.
• Contact gap of 3 mm minimum.
• UL and cUL standard approved, Conforming to EN standards.
• Model variation for 3.3VDC circuit.
RoHS Compliant
(Please refer the Precautions)
Usage example
Saving energy
by
cutting the standby power.
Saving energy
by
preventing forgetting to turn OFF main power.
Turning OFF main power
by
remote.
Turning OFF main power of many equipments at the same time.
*
There are 2 kinds of main models A8GS. (Delay OFF Function model and Remote Reset model) With regard to the models with Delay OFF Function, please refer to the other catalog.
List of Models
1. Reset function type
SPST
Contact Form
1 to 2: Power contact terminal
a, b: Micro load contact terminal
+, -: Coil terminal
Terminals
Reset voltage
No Marking
Marking on caps
Micro load contact terminal
×
1
+
-
a
b
+
-
1
Power contact terminal
×
1
2
+
-
1
2
Quantity
per box
CT Connector
5V model
A8GS-S1105
A8GS-S1205
A8GS-S1305
3.3V model
A8GS-S1103
A8GS-S1203
A8GS-S1303
Quick-connect terminals
#187 (t=0.8)
5V model
3.3V model
A8GS-P1185
A8GS-P1183
A8GS-P1285
A8GS-P1385
A8GS-P1283
A8GS-P1383
Solder terminals
5V model
A8GS-P1115
A8GS-P1215
A8GS-P1315
3.3V model
A8GS-P1113
A8GS-P1213
A8GS-P1313
50
Contact Form
1 to 2: Power contact terminal
a, b: Micro load contact terminal
+, -: Coil terminal
Terminals
Reset voltage
No Marking
Marking on caps
DPST
Micro load contact terminal
×
1
+
Power contact terminal
×
1
+
-
1
a
2
b
Quantity
per box
Micro load contact terminal : CT Connector
Micro load contact terminal : CT Connector
Power contact terminal : Quick-connect
Power contact terminal : Solder terminals
terminals #187 (t=0.8)
5V model
3.3V model
5V model
3.3V model
A8GS-C1185
A8GS-C1183
A8GS-C1115
A8GS-C1113
A8GS-C1285
A8GS-C1385
A8GS-C1283
A8GS-C1383
A8GS-C1215
A8GS-C1315
A8GS-C1213
A8GS-C1313
50
1
Announcement of Moderator Chip Coin Rewards in October 2014
[align=left][font=微软雅黑][size=4]According to EEWORLD moderator rules and moderator operation manual[/size][/font][/align][align=left][url=https://bbs.eeworld.com.cn/thread-370268-1-1.html][font=微软雅黑][s...
EEWORLD社区 Suggestions & Announcements
Senior engineers teach you step by step: How to use the simulator program
Keithley engineers have been committed to product innovation and RD, and have generously shared core technologies and application operations with everyone. As one of them, I also discussed with my fel...
Jack_ma Test/Measurement
Showing the process of WEBENCH design + FPGA power supply
1. Enter WEBENCHSelect the FPGA you want to design and click to enter 2. This time select EP4CE223. Check if the power supply is neededClick "Add multiple loads" 4. Check if the input voltage, output ...
dontium Analogue and Mixed Signal
How to get the handle of the window with focus in other processes in CE? Waiting online
Can anyone tell me how to get the handle of the window with focus in another process under CE? It seems that CE does not support the AttachThreadInput function. Is there any other way? I am currently ...
王增 Embedded System
High-Throughput Laser Diode Module and VCSEL DC Production Testing Using the Model 2602 SourceMeter
Laser diodes ( LD ) and vertical cavity surface emitting lasers ( VCSEL ) are two major components in optical communications, spectroscopy, and many other important applications. As the demand for the...
Jack_ma Test/Measurement
Looking for the USB driver used by dnw
I burned in the loader.bin provided by the manufacturer, and after turning on the power, dnw got the boot options: 0=wince by usb 1=wince by sd/mmc 2=loader by usb 3=loader by sd/mmc After I selected ...
alec_chu Embedded System

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1085  1591  2573  954  1506  22  33  52  20  31 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号