EEWORLDEEWORLDEEWORLD

Part Number

Search

VI-23Y-CU-F4

Description
Isolated DC/DC Converters 48V/3.3V 40A CONVERTER FIN
CategoryPower/power management    The power supply circuit   
File Size691KB,8 Pages
ManufacturerVICOR
Websitehttp://www.vicorpower.com/
Download Datasheet Parametric View All

VI-23Y-CU-F4 Online Shopping

Suppliers Part Number Price MOQ In stock  
VI-23Y-CU-F4 - - View Buy Now

VI-23Y-CU-F4 Overview

Isolated DC/DC Converters 48V/3.3V 40A CONVERTER FIN

VI-23Y-CU-F4 Parametric

Parameter NameAttribute value
Is it lead-free?Contains lead
Is it Rohs certified?incompatible
MakerVICOR
Parts packaging codeMODULE
package instruction4.600 X 2.400 INCH, 0.500 INCH HEIGHT, MODULE-9
Contacts9
Reach Compliance Codenot_compliant
ECCN codeEAR99
Analog Integrated Circuits - Other TypesDC-DC REGULATED POWER SUPPLY MODULE
CertificationUL; CE; VDE; CSA; TUV; BABT
Efficiency (main output)80%
Maximum input voltage60 V
Minimum input voltage42 V
Nominal input voltage48 V
JESD-30 codeR-XDMA-P9
JESD-609 codee0
Maximum grid adjustment rate0.05%
Maximum load regulation0.05%
Number of functions1
Output times1
Number of terminals9
Maximum operating temperature85 °C
Minimum operating temperature-25 °C
Maximum output voltage3.63 V
Nominal output voltage3.3 V
Package body materialUNSPECIFIED
Package shapeRECTANGULAR
Package formMICROELECTRONIC ASSEMBLY
Peak Reflow Temperature (Celsius)NOT SPECIFIED
ProtectTHERMAL; CURRENT; OUTPUT OVER VOLTAGE
Certification statusNot Qualified
surface mountNO
technologyHYBRID
Temperature levelOTHER
Terminal surfaceTIN LEAD OVER COPPER
Terminal formPIN/PEG
Terminal locationDUAL
Maximum time at peak reflow temperatureNOT SPECIFIED
Fine-tuning/adjustable outputYES
DC-DC Converters
VI-200
VE-200
®
S
C
US
C
NRTL
US
50 to 200 Watts
Features & Benefits
Isolated output
Up to 50W/in
3
cURus, cTÜVus
Up to 90% efficiency
Size: 4.6” x 2.4” x 0.5”
(116,8 x 61,0 x 12,7mm)
Remote sense and current limit
OVP, thermal shutdown
Logic disable
Wide range output adjust
Compatible power booster modules
ZCS power architecture
Low noise FM control
CE Marked
RoHS compliant (VE-200)
Product Highlights
The VI-200 family, with over 14 million units shipped, is Vicor’s broad series of
“zero-current-switching” component-level DC-DC converters.
Operating at frequencies up to 2MHz, VI-200 family converters offer exceptional power
density, efficiency, noise performance, reliability and ease of use. Booster modules
(VI-Bxx) provide a simple, cost-effective, off-the-shelf solution for higher power output
requirements. One or more boosters may be used to create synchronous arrays capable
of supplying several kilowatts of output power.
The flexibility of Vicor’s power components is also available in half-size, half-power
VI-J00 MiniMods.
Part Numbering
VI
2
6
1
C
W
Family
VI
=Non-RoHS
VE
= RoHS
Series
2
= 200
B
= Booster
0
= 12V
V
= 24V
1
= 24V
W
= 24V
2
= 36V
3
= 48V
Input
N
= 48V
4
= 72V
T
= 110V
5
= 150V
6
= 300 V
7
= 150/300V
Z
= 2V
Y
= 3.3V
0
= 5V
X
= 5.2V
W
= 5.5V
V
= 5.8V
T
= 6.5V
R
= 7.5V
Output
M
= 10V
1
= 12V
P
= 13.8V
2
= 15V
N
= 18.5V
3
= 24V
L
= 28V
J
= 36V
K
= 40V
4
= 48V
H
= 52V
F
= 72V
D
= 85V
B
= 95V
Grade
E
= –10 to 85°C
C
= –25 to 85°C
I
= – 40 to 85°C
M
= –55 to 85°C
≥ 5V
Power
< 5V
U
= 40A
V
= 30A
W
= 20A
X
= 15A
Y
= 10A
U
= 200W
V
= 150W
W
= 100W
X
= 75W
Y
= 50W
Note:
For additional
packaging options,
please see page 5.
VI-200 DC-DC Converters
Page 1 of 7
Rev 3.9
08/2017
The longest red light in history - 2045 seconds
You are certainly familiar with traffic lights, but how many seconds is the longest waiting time for a red light you have ever seen? 2045 seconds.On January 22, Mr. Yang from Chongqing drove past the ...
小瑞 Industrial Control Electronics
Photoelectric encoder classification
Encoder is a type of sensor, mainly used to detect the speed, position, angle, distance or count of mechanical movement. In addition to being used in industrial machinery, many motor controls such as ...
jek9528 Industrial Control Electronics
C2000 chip at minus 35 degrees...
I encountered a problem today. The C2000 board can run normally at room temperature, but not at low temperature........At room temperature, all tests were normal for power supply, crystal oscillator, ...
hlx3012 Microcontroller MCU
If you want to make the three-pole tube work in the amplification area, what is the idea? You need to calculate the static working point ib ic VCE three...
If you want to make the triode work in the amplification area, what is the idea? Do you need to calculatethe three parameters of static working point ib ic VCE? Then what? If you don’t know RB RC, how...
QWE4562009 Integrated technical exchanges
Sensor section official QQ group: 285537089
Sensor section official QQ group: 285537089Welcome to join the real-time discussion of sensor issues. You can discuss sensor products, even your own products, in the group, but hard advertising is str...
laoguo Sensor
Using SPICE to simulate high-precision digital-to-analog converters
[i=s]This post was last edited by qwqwqw2088 on 2015-3-15 13:02[/i] [align=left][color=#000] Perhaps the most dreaded and stressful moment for engineers is when their designs come back from the manufa...
qwqwqw2088 Analogue and Mixed Signal

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 248  2258  219  16  850  5  46  1  18  25 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号