Assembly Instructions-C56
SMA
Amphenol
®
BRAID CRIMP-SOLDER CENTER CONTACT TYPES FOR FLEXIBLE CABLE
shrink
tubing
outer
ferrule
clamp nut &
inner ferrule
insulator
washer
male
contact
plug body
female
contact
bulkhead jack
or jack body
Amphenol
Number
901-9601-1SF
901-9601-3
901-9601-3SF
901-9602-1, -1SF
901-9602-3, -3SF
901-9602-12SF
901-9610-1SF
901-9610-3, -3SF
901-9610-12SF
901-10015
Connector
Type
SMA Plug
SMA Plug
SMA Plug
SMA Jack
SMA Jack
SMA Jack
SMA Bulkhead Jack
SMA Bulkhead Jack
SMA Bulkhead Jack
SMA Bulkhead Jack
Cable RG-/U
55,58,141,142,223,400
174,179,187,188,316
174,179,187,188,316
55,58,141,142,223,400
174,179,187,188,316
Double Braid 316
55,58,141,142,223,400
174,179,187,188,316
Double Braid 316
LMR 240
Strip Dimensions, inches (mm)
a
.620(15.7)
.620(15.7)
.620(15.7)
.610(15.5)
.610(15.5)
.610(15.5)
.610(15.5)
.610(15.5)
.610(15.5)
4.93(12.5)
b
.350(8.9)
.350(8.9)
.350(8.9)
.340(8.6)
.340(8.6)
.340(8.6)
.340(8.6)
.340(8.6)
.340(8.6)
—
c
.120(3.0)
.120(3.0)
.120(3.0)
.110(2.8)
.110(2.8)
.110(2.8)
.110(2.8)
.110(2.8)
.110(2.8)
.043(2.4)
Hex Cavity for
Outer Ferrule
.213(5.4)
.128(3.3)
.128(3.3)
.213(5.4)
.128(3.3)
.128(3.3)
.213(5.4)
.128(3.3)
.151(3.8)
.255(6.5)
Die Set for
Tool 227-944
227-1221-11 Cavity A
227-1221-03 Cavity A
227-1221-03 Cavity A
227-1221-11 Cavity A
227-1221-03 Cavity A
227-1221-03 Cavity A
227-1221-11 Cavity A
227-1221-03 Cavity A
227-1221-37 Cavity B
227-1221-59 Cavity A
Step 1
a
b
c
Step 1
Slide heat shrink tubing and outer ferrule onto cable. Strip
cable jacket, braid and dielectric to dimensions shown in
table above. All cuts are to be sharp and square. Do not nick
braid, dielectric or center conductor when cutting. Tin center
conductor. Avoid excessive heat to prevent swelling of cable
dielectric. Flare end of cable braid slightly as shown to facilitate
insertion of inner ferrule. Do not comb out braid.
Step 2
Slide clamp nut over inner ferrule, and slide inner ferrule
under braid until cable dielectric is flush with front of inner
ferrule. Slide outer ferrule in place and crimp with die set
shown in table above.
Step 2
Step 3
insulator washer
Step 3
Place insulator washer on cable center conductor and
bottom against inner ferrule body as shown. Contact must
butt firmly against insulator washer while soldering.
Step 4
Step 4
Screw ferrule-contact assembly into body and tighten to
20-25 lbf.-in. torque. Slide heat shrink tubing over ferrule,
up against clamp nut and shrink by applying heat.
Amphenol Corporation Tel: 800-627-7100
www.amphenolrf.com
324