EEWORLDEEWORLDEEWORLD

Part Number

Search

43015209

Description
AC Power Entry Modules KEA PWR ENTRY MODUL W. FILTER 10A M5
CategoryThe connector   
File Size1MB,11 Pages
ManufacturerSCHURTER
Websitehttp://www.schurterinc.com/
Download Datasheet Parametric Compare View All

43015209 Online Shopping

Suppliers Part Number Price MOQ In stock  
43015209 - - View Buy Now

43015209 Overview

AC Power Entry Modules KEA PWR ENTRY MODUL W. FILTER 10A M5

43015209 Parametric

Parameter NameAttribute value
Product AttributeAttribute Value
ManufacturerSCHURTER
Product CategoryAC Power Entry Modules
ProductInlets
FilteredFiltered
FusedYes
Switch FunctionSwitched
NumOfPackaging1
Factory Pack Quantity10
Unit Weight2.328081 oz
Power Entry Modules with Line Filter
https://www.schurter.com /PG06
KFA
IEC Appliance Inlet C14 with Filter, Fuseholder 1- or 2-pole, optional Voltage Selector (step switch)
Screw-on mounting from front side
Version with ground line choke
without voltage selector
Fuse drawer must be ordered separately (see
accessories).
Snap-in mounting from front side
without voltage selector
Fuse drawer must be ordered separately (see
accessories).
Screw-on mounting from rear side
without voltage selector
Fuse drawer must be ordered separately (see
accessories).
C14
Approvals and Compliances
70° C
See below:
Description
- Panel Mount :
Screw-on version from front or rear side, snap-in version from front
side
- 4 Functions :
Appliance Inlet Protection class I , Fuseholder for fuse-links 5 x 20 mm
1- or 2-pole , with or without voltage selector (step switch) , Line filter
in standard and medical version
- V-Lock notch standard
- Quick connect terminals or wires
Characteristics
- Rear side mounting for efficient costsaving assembly
Suitable for assembly in metal plated plastic housings
- All single elements are already wired
- Plug removal necessary for fuse-link replacement
- Suitable for use in equipment according to IEC/UL 60950
Suitable for use in medical equipment according to IEC/UL 60601-1
Other versions on request
- Capacity CX 100 nF
Unique Selling Proposition
-
-
-
-
References
Weblinks
Reduces noise on the ground wire
Interrupts ground loops
High asymmetrical attenuation
V-Lock cord retaining
Alternative: version without line filter
KEA
pdf datasheet, html-datasheet, General Product Information, Distributor-
Stock-Check, Accessories, Detailed request for product, Microsite
Technical Data
Ratings IEC
Ratings UL/CSA
Leakage Current
Dielectric Strength
1 - 10 A @ Ta 40 °C / 250 VAC; 50 Hz
1 - 10 A @ Ta 40 °C / 125 VAC; 60 Hz
standard < 0.5 mA (250 V / 60 Hz)
medical < 5 µA (250 V / 60 Hz)
> 1.7 kVDC between L-N
> 2.7 kVDC between L/N-PE
Test voltage (2 sec)
-25 °C to 85 °C
25/085/21 acc. to IEC 60068-1
from front side IP 40 acc. to IEC 60529
Suitable for appliances with protection
class I acc. to IEC 61140
Quick connect terminals 6.3 x 0.8 mm
Flexible wire AWG18, 150 mm
Screw: max 8 mm
Mounting screw torque max 0.5 Nm
Snap-in: 0.8 mm to 3 mm
Thermoplastic, black, UL 94V-0
appliance inlet/-outlet
C14 acc. to IEC 60320-1,
UL 498, CSA C22.2 no. 42 (for cold
conditions) pin-temperature 70 °C, 10 A,
Protection Class I
1 or 2 pole, Shocksafe category PC2
acc. to IEC 60127-6,
for fuse-links 5 x 20 mm
5 x 20: 2 W (1 pole)/ 1.6 W (2-pole) per
pole
Admissible power acceptance at higher
ambient temperature see derating cur-
ves
optional, step, 3 pos.
Standard and Medical Version, IEC
60939, UL 1283, CSA C22.2 no. 8
Technical Details
> 1'700'000 h acc. to MIL-HB-217 F
Fuseholder
Allowable Operation Tempe-
rature
Climatic Category
IP-Protection
Protection Class
Terminal
Panel Thickness S
Rated Power Acceptance @
Ta 23 °C
Power Acceptance @ Ta >
23°C
Voltage Selector
Line Filter
MTBF
Material: Housing
Approvals and Compliances
Detailed information on product approvals, code requirements, usage instructions and detailed test conditions can be looked up in
Details about
Approvals
EMC Products
1

43015209 Related Products

43015209 43016206 43016201 43016001 43015055 43015053
Description AC Power Entry Modules KEA PWR ENTRY MODUL W. FILTER 10A M5 AC Power Entry Modules KFA POWER ENTRY MODULE W AC Power Entry Modules 1A DP FUSEHOLDER WITH MEDICAL FILTER AC Power Entry Modules 1A DP FUSEHOLDER WITH STD FILTER AC Power Entry Modules KEA PWR ENTRY MODUL W. FILTER 10A AC Power Entry Modules KEA PWR ENTRY MODUL W. FILTER 4A
Product Attribute Attribute Value Attribute Value Attribute Value Attribute Value Attribute Value Attribute Value
Manufacturer SCHURTER SCHURTER SCHURTER SCHURTER SCHURTER SCHURTER
Product Category AC Power Entry Modules AC Power Entry Modules AC Power Entry Modules AC Power Entry Modules AC Power Entry Modules AC Power Entry Modules
Product Inlets Inlets Inlets Inlets Inlets Inlets
Filtered Filtered Filtered Filtered Filtered Filtered Filtered
Fused Yes Yes Yes Yes Yes Yes
Switch Function Switched Switched Switched Switched Switched Switched
Factory Pack Quantity 10 10 10 10 10 10
Unit Weight 2.328081 oz 2.257534 oz 2.257534 oz 2.328081 oz 2.116438 oz 2.116438 oz

Technical ResourceMore

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1003  660  560  1972  1350  21  14  12  40  28 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号