EEWORLDEEWORLDEEWORLD

Part Number

Search

FBP-350

Description
Specialty Fuses SEMI CONDUCTOR FUSE
CategoryCircuit protection   
File Size69KB,3 Pages
ManufacturerEaton
Download Datasheet Parametric View All

FBP-350 Online Shopping

Suppliers Part Number Price MOQ In stock  
FBP-350 - - View Buy Now

FBP-350 Overview

Specialty Fuses SEMI CONDUCTOR FUSE

FBP-350 Parametric

Parameter NameAttribute value
Product AttributeAttribute Value
ManufacturerEaton
Product CategorySpecialty Fuses
RoHSN
ProductSpecialty Fuses
Body StyleCartridge Blade Fuses
Current Rating350 A
Voltage Rating AC700 VAC
Voltage Rating DC700 VDC
Mounting StyleStud
Termination StyleBolt Down
Fuse TypeFast Blow
Indicator StyleWithout Indicator
PackagingBulk
Height31 mm
Length129 mm
TypeSemiconductor Fuse
Width54 mm
NumOfPackaging1
Factory Pack Quantity1
Unit Weight0.016000 oz
Bussmann
®
Semiconductor Fuses
700 Volts AC/DC, 35-1000 Amps
FBP
CATALOG SYMBOL: FBP
700V AC, 700V DC
INTERRUPTING RATING 200,000 AMPERES
RMS SYMMETRICAL
U.L. RECOGNIZED
(GUIDE #JFHR2, FILE # E56412)
Catalog Numbers
FBP-35
FBP-40
FBP-50
FBP-60
FBP-70
FBP-80
FBP-90
FBP-100
FBP-125
FBP-150
FBP-175
FBP-200
FBP-250
FBP-300
FBP-350
FBP-400
FBP-450
FBP-500
FBP-600
FBP-700
FBP-800
FBP-900
FBP-1000
Ultra High Degree of Current Limitation and Low I
2
t.
• The heat energy of even low-level fault currents can quickly
destroy a semiconductor device.
* Buss FW type fuse limits peak let-thru current to a level
which is a fraction of the potential available short-circuit peak
current.
• Fast speed-of-response to build-up of short-circuit current
and the quickly decaying short-circuit current as the fuse
suppresses internal arcing together can limit the I
2
t let-thru to
values substantially lower than the I
2
t withstand of the semi-
conductor device.
Current Rating.
• Current rating is given in AC (rms) for an ambient tempera-
ture of 20ºC (68ºF).
• Although these fuses can be operated at 100% of rating,
good design practice dictates some derating (i.e. for ambient
temperature), typically this is 20%.
Voltage Rating.
• Rated voltage of Semiconductor fuses is given in terms of
A.C. operation, 60Hz.
• When used in D.C. circuits no voltage derating is required
provided the minimum interrupting capability is eight times
the fuse rating and the time constant does not exceed those
specified in U.L. 198L.
Total Clearing I
2
t.
• Maximum values of total clearing I
2
t are obtained at the rated
A.C. voltage, an arcing angle between 60º and 90º, at an
available symmetrical rms current of 100,000 amperes, and
at a power factor of less than 15%.
Arc Voltage.
• The arc voltage which develops across a fuse when it is
clearing a fault current must always exceed the system volt-
age.
• This arc voltage may reach a value which is twice that of the
system applied voltage.
12-17-98
SB98107
Rev. A
Form No. FBP
Page 1 of 3
BIF Doc #720041

Technical ResourceMore

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1445  2183  1129  15  652  30  44  23  1  14 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号