V13
Specifications
INPUT SPECIFICATIONS:
Voltage …....………........…........................................... 90~264Vac
Frequency ………………………………………….……………..... 47 to 63Hz
Inrush Current …………… Cold Start@25℃ ............... 50A max. @240Vac
Leakage Current ……………………………………………...…… 3.5mA max.
CFM60T Series Derating Curve
100%
Rated Load (%)
75%
50%
25%
0%
0
10
20
30
40
Ambient Temperature (
o
C)
50
60
20LFM (Natural Convection)
OUTPUT SPECIFICATIONS:
Holdup Time ……………………………………………… 8ms typ. @115Vac
Short Circuit ………………………….…….… Hiccup Mode (Auto Recover)
Over Voltage Protection …………………..…...…... 6V/7V on V1(3.3V/5V)
15V/18V/28V on V2(12V/15V/24V)
Temperature Coefficient ……………………............................... ±0.05%/℃
GENERAL SPECIFICATIONS:
Isolation ………………………………….……… Input to output = 4,242VDC
Operating Temperature ........................... 0 ~ 60℃ (see Derating Curve)
Storage Temperature …………………..………...…....……........ -20 ~ 85℃
Humidity .................................................... 93% RH max. Non-Condensing
Cooling …………………………………………………….. Natural Convection
Switching Frequency …………………………….…….……. 65KHz Typical
MTBF …………….… MIL-HDBK-217F, GB, 25℃/115VAC …… T.B.D hrs
Altitude ……………………..……………………………….………….… 2000m
Dimensions …………. 4.000x2.000x1.260Inches (101.60x50.80x32.00mm)
Weight …………………………………….…………….. 170g (0.37 Pounds)
NOTE:
1. Voltage accuracy is set of 60% rated load.
2. Add a 0.1uF ceramic capacitor and a 10uF E.L. capacitor to output for
Ripple & Noise measuring @20MHz BW.
3. Line regulation is measured from 103Vac~127Vac & 207Vac~253Vac with
rated load.
4. Load regulation is defined by changing ±40% of measured output load
from 60% rated load at other outputs set to 60% rated load.
5. Input connector mates with Molex housing 09-50-3031 and Molex
2878 series crimp terminal.
6. Output connector mates with Molex housing 09-50-3061 and Molex
2878 series crimp terminal.
SAFETY AND EMC:
Emission and Immunity …….…... EN55022 Class B, FCC Part 15 Class B
EN61000-3-2, EN61000-3-3, EN55024
Safety ……………….……………… IEC60950-1, EN60950-1, UL60950-1
CFM60T Series
All Dimensions are in inches[mm]
Tolerances
:
Inches
:
X.XXX±0.02
N
L
00.126 [3.20]
3.748 [95.20]
4.000 [101.60]
Typical at 25˚C, nominal line and 75% load, unless otherwise Specified
2
00.079 [2.00]Max.
00.063 [1.60]
00.125 [3.18]
V2
V1
V1
GND
GND
V3
1.750 [44.45]
2.000 [50.80]