EEWORLDEEWORLDEEWORLD

Part Number

Search

2026-47-C

Description
Gas Discharge Tubes - GDTs / Gas Plasma Arrestors Sparkover100V/s 470V 3 Pole
CategoryWireless rf/communication    Telecom circuit   
File Size327KB,5 Pages
ManufacturerBourns
Websitehttp://www.bourns.com
Environmental Compliance
Download Datasheet Parametric View All

2026-47-C Online Shopping

Suppliers Part Number Price MOQ In stock  
2026-47-C - - View Buy Now

2026-47-C Overview

Gas Discharge Tubes - GDTs / Gas Plasma Arrestors Sparkover100V/s 470V 3 Pole

2026-47-C Parametric

Parameter NameAttribute value
Is it Rohs certified?conform to
Reach Compliance Codeunknown
Factory Lead Time5 weeks
JESD-30 codeO-XXSS-P3
Number of functions1
Number of terminals3
Maximum operating temperature85 °C
Minimum operating temperature-55 °C
Package body materialUNSPECIFIED
Package shapeROUND
Package formSPECIAL SHAPE
Certification statusNot Qualified
surface mountNO
Telecom integrated circuit typesSURGE PROTECTION CIRCUIT
Temperature levelOTHER
Terminal formPIN/PEG
Terminal locationUNSPECIFIED
Base Number Matches1
*R
oH
VE S CO
AV R M
AI SIO PL
LA N IA
BL S NT
E
Features
Balanced TRIGARD
®
Approximately 8 mm diameter, 11 mm long
UL Recognized
Custom configurations available
High surge current rating
Stable breakdown throughout life
RoHS compliant* version available
Applications
Telecommunications
Industrial electronics
Commercial electronics
Consumer electronics
Aircraft and military electronics
2026 Series - 3-Pole Gas Discharge Tube
Characteristics
Test Methods per ITU-T K.12, IEEE C62.31 and IEC 61643-311 GDT standards.
Characteristic
DC Sparkover ±20 % @ 100 V/s
Impulse Sparkover
(1)
100 V/μs
1000 V/μs
Characteristic
DC Sparkover ±20 % @ 100 V/s
Impulse Sparkover
(1)
100 V/μs
1000 V/μs
(1)
Model No.
2026-07
75 V
275 V
700 V
2026-09
90 V
275 V
600 V
2026-15
150 V
350 V
575 V
2026-20
200 V
425 V
625 V
2026-23
230 V
450 V
650 V
2026-25
250 V
475 V
700 V
2026-26
260 V
475 V
700 V
Model No.
2026-30
300 V
550 V
775 V
ribution.
2026-35
350 V
625 V
875 V
2026-40
400 V
675 V
925 V
2026-42
420 V
725 V
1000 V
2026-47
470 V
800 V
1100 V
2026-60
600 V
925 V
1250 V
Impulse Transverse Delay.............................................1000 V/μs ................................................................. < 75 ns
Insulation Resistance ...................................................100 V (50 V for Model 2026–07 & 2026-09) ............. > 10
10
Ω
Glow Voltage ................................................................10 mA ....................................................................... ~ 70 V
Arc Voltage ...................................................................1A ............................................................................. ~ 10 V
Glow-Arc Transition Current ........................................................................................................................... < 0.5 A
Capacitance .................................................................1 MHz ....................................................................... < 2 pF
DC Holdover Voltage
(2)
...............................................>135 V, (52 V for Model 2026-07 & 2026-09, ........... < 150 ms
80 V for Model 2026-15)
Impulse Discharge Current ...........................................40000 A, 8/20
μs
(3)
.................................................. 1 operation minimum
20000 A, 8/20
μs
...................................................... > 10 operations
5000 A, 10/350
μs
................................................... 1 operation
1000 A, 10/1000
μs
................................................. > 400 operations
Alternating Discharge Current ......................................130 Arms, 11 cycles
(3)
............................................. 1 operation minimum
20 Arms, 1 s ............................................................. > 10 operations
Operation and Storage Temperature .............................................................................................................. -40 to +90 °C
Climatic Category (IEC 60068-1) .................................................................................................................... 40/ 90/ 21
Moisture Sensitivity Level ............................................................................................................................... 1
............................................................................................................................... 6
An optional Switch-Grade Fail-Short device is available. The optional Fail-Short assembly will activate at a temperature of 215 °C – 217 °C
to provide a high conductive path to ground in case of a thermal overload. GDTs equipped with the optional Fail-Short device should be
soldered either manually at a temperature that is below the activation temperature of the Fail-Short mechanism, or using a selective soldering
process that does not exceed 210 °C.
Notes:
• Model number marking on tube: 26-xxx V.
• The rated discharge current for TRIGARD
®
Gas Discharge Tubes is the total current equally divided between each line to ground.
• Sparkover limits after life ±25 %, IR >108
Ω
(-25 %,+30 % for Model 2026-07, 2026-09 and 2026-60).
• Line to Line voltage is approximately 1.8 to 2 times the stated Line to Ground breakdown voltage.
• At delivery AQL 0.65 Level II, DIN ISO 2859
(2)
(3)
Network applied.
DC Sparkover may exceed ±25 % after discharge, but will continue to protect without venting.
WARNING Cancer and Reproductive Harm
www.P65Warnings.ca.gov
*RoHS Directive 2002/95/EC Jan. 27, 2003 including annex and RoHS Recast 2011/65/EU June 8, 2011.
Specifications are subject to change without notice. Users should verify actual device performance in their specific
applications. The products described herein and this document are subject to specific legal disclaimers as set forth on the
last page of this document, and at
www.bourns.com/docs/legal/disclaimer.pdf.
Illustrated Practical Electronic Technology Series High-Speed Digital Circuit Design and Installation Techniques
[color=#555555][backcolor=rgb(247, 247, 247)][size=12px][b]Illustrated Practical Electronic Technology Series High-Speed Digital Circuit Design and Installation Skills[/b][/size][/backcolor][/color] [...
qq849682862 PCB Design
MSP430ADC deviation is too large
When I was practicing, I found that when I used ADC to measure voltage, I wrote the following program and then measured the ground of the microcontroller. The displayed voltage was always not zero, wi...
hakunamatata_hg Microcontroller MCU
Let's take a look at the USB-485 I made.
Please take a look at the USB-485 I made, the circuit board made by protel99se (with complete schematics and circuit boards) Two chips are used: CH341T and SP485EEN. Welcome to download....
tzl MCU
Qorvo 100 MHz Envelope Tracking Solution for 5G
[i=s]This post was last edited by alan000345 on 2019-5-29 09:00[/i] [p=25, null, left]As cellular technology evolves, modulation complexity increases, and the requirements for RF components become mor...
alan000345 RF/Wirelessly
How to connect multiple devices to one serial port?
I use CitectSCADA 7 to do it, using a multi-serial port server, one serial port connects to 10 Schneider MC08, and one serial port connects to 5 Sepam 40. Now I want to realize its interface communica...
eeleader Industrial Control Electronics
【Beetle ESP32-C3】3. Adjust LED brightness with knob (potentiometer) (Arduino)
1. Functional descriptionThis article introduces the process of using a knob to control the brightness of an LED. The knob uses a potentiometer, which generates voltage changes when rotated, and then ...
sonicfirr RF/Wirelessly

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1660  795  596  22  1041  34  16  12  1  21 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号