EEWORLDEEWORLDEEWORLD

Part Number

Search

PGC-5095

Description
Current Transformers CT 3.75" ID (95mm) - WKE95
CategoryPower/power management   
File Size722KB,3 Pages
ManufacturerLittelfuse
Websitehttp://www.littelfuse.com
Download Datasheet Parametric View All

PGC-5095 Online Shopping

Suppliers Part Number Price MOQ In stock  
PGC-5095 - - View Buy Now

PGC-5095 Overview

Current Transformers CT 3.75" ID (95mm) - WKE95

PGC-5095 Parametric

Parameter NameAttribute value
Product AttributeAttribute Value
ManufacturerLittelfuse
Product CategoryCurrent Transformers
RoHSN
PackagingBulk
Factory Pack Quantity1
Accessories
Current Transformers (CTs)
CT SELECTION GUIDE
PRODUCT
SE-601
PGR-3100
PGR-3200
GROUND FAULT
PROTECTION
GROUND-FAULT CT
No CTs required
No CTs required
No CTs required
No CTs required
CT-200 Series
GROUND-FAULT TRIP LEVEL
(or insulation level)
1-20 mA
Indication only
Warnings at 30 kΩ & 50 kΩ,
Alarm at 10 kΩ
5 ± 0.9 mA
10-198 A
50 mA-4.95 A
300 mA-29.7 A
10 mA-5 A
30-5,000 mA AC and DC
0.5-4 A
0.5-12.5 A
0.5-12.5 A
2.0-50 A
12-200 A
100 mA-5 A
600 mA-30 A
0.5-4 A
0.4-150 A
10-200 A
50 mA-5 A
300 mA-30 A
10-200 A
50 mA-5 A
300 mA-30 A
SE-502
SE-701/SE-703
SE-704
EL731
SE-105/SE-107
SE-134C/SE-135
SE-145
EFCT Series
SE-CS30 Series
SE-CS30 Series
EFCT Series
CT200 Series
SE-CS10 Series
SE-CS10 Series
SE-CS40 Series
CT200 Series
EFCT Series
SE-CS30 Series
CT200 Series
No phase CTs required <25 A,
Optional SE-CS30 Series Ground-Fault CT
CT200 Series
EFCT Series
SE-CS30 Series
CT200
RESISTANCE
GROUNDING
TRAILING CABLE
PROTECTION
SE-330
SE-325
PGR-6150
MPU-32*
MOTOR & PUMP
PROTECTION
MPS*
MPU-32-X69X-PMA16
MPS-469X-PMA24
PGR-6800
FPU-32*
EFCT Series (5-A Primary)
SE-CS30 Series (30-A Primary)
Existing CTs can be used or same as MPU-32.
Existing CTs can be used or same as MPS.
No CTs required <91 A
CT200 Series
EFCT Series
SE-CS30 Series
CT200
N/A
10-200 A
50 mA-5 A
300 mA-30 A
10-200 A
50 mA-5 A
300 mA-30 A
N/A
FEEDER
PROTECTION
FPS*
AF1000
EFCT Series (5-A Primary)
SE-CS30 Series (30-A Primary)
CTs are optional
ARC-FLASH
PROTECTION
*Phase CTs should be selected with a primary rating of 100-300% of rated current to maintain specified accuracy. CTs with a 1-A or 5-A secondary are accepted.
†Trip levels are model specific, see ordering information..
‡Select a CT with a primary rating approximately equal to the system’s rated current. CTs with 5-A secondary current are accepted.
© 2014 Littelfuse Protection Relays & Controls
Rev: 4-B-061214

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2444  185  493  1972  2830  50  4  10  40  57 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号