Parameter NameAttribute value
Actuator typepush to reset
Circuit breaker typeThermal control
illuminationno
Luminous typeNot glowing
circuit functionSeries trip
Grounding switchWithout
Panel cutout (in).441 x .394
Rated AC voltage (VAC)250
Rated current (A)10
interrupt capability1000A @ 250VAC/50VDC
button colorWhite with red rating mark (vertical)
Electrode configuration1
Action time at 200% (seconds)4 – 40
Termination type6.35 [.25] Straight Quick Connect Male
Installation typePanel mounting
Install casing9.8 x 9.6 mm long, plastic
Installation optionsKnurled Nut/Hexagonal Nut
Install hardware packageAlready assembled to bushing
Catalog 1308242
Issued 4-15 (PDF Rev. 04-15)
Potter & Brumfield
W57
series
Compact, Push To Reset Only
P&B Thermal Circuit Breaker
Features
• New, compact design.
• 3 to 20 amp ratings.
• Cannot be manually tripped.
• Button extends for visual trip indication.
• Push button to reset breaker.
• Numerous mounting and termination options.
• Optional bottom marking of amperage rating.
Insulation Resistance: 100 megohms.
Maximum Operating Voltages:
50VDC; 250VAC, 50/60 Hz.
Interrupt Capacity: 1,000 amps in accordance with UL standard 1077.
Resettable Overload Capacity:
Ten times rated current.
Reset Time: 60 seconds.
Typical Resistance vs. Current Rating @ +25°C
Current
Rating
in Amps
3.0
4.0
5.0
6.0
7.0
Typical
Resistance
in Ohms
0.083
0.062
0.050
0.042
0.036
Current
Rating
in Amps
8.0
10.0
12.0
15.0
20.0
Typical
Resistance
in Ohms
0.031
0.025
0.021
0.017
0.012
Agency Approvals
W57 series is UL1077 Recognized as Supplementary Protectors,
File E69543, for Canada and the United States. Available models
meet Ignition Protection requirements in accordance with UL1500.
Approved to VDE 0642/EN60934 (Circuit Breakers for Equipment)
License Number 40007874 (excludes models rated 3-4A and >15A).
CCC mark compliant, certificate 2004010307123217.
Users should thoroughly review the technical data before selecting a product part
number. It is recommended that users also seek out the pertinent approvals files
of the agencies/labora-tories and review them to confirm the product meets the
requirements for a given application.
Electrical Data @ 25°C
Calibration: Will continuously carry 100% of rating.
May trip between 101% and 134%, but must trip at 135% of
rating within one hour at +25°C.
Dielectric Strength: 1,500VAC (60 seconds).
Mechanical/Environmental Data
Operating Temperature Range:
0°C to +60°C.
Termination: .250” (6.35mm) quick connects.
Mounting:
Various options. See Ordering Information and drawings.
Approximate Weight: 0.5 oz. (14.3g).
Time vs. Current Trip Curve @ +25°C
1000
900
800
Load Current As A Percent
Of Breaker Rating
700
600
500
400
300
200
100
0
.1
1
10
100
Time In Seconds
1000
10,000
135
Outline Dimensions
Overload
100%
135%
200%
300%
400%
500%
600%
800%
1000%
Trip Times
No Trip
Trip in 1 hour
4.0 - 40.0 Sec.
1.2 - 12.0 Sec.
0.6 - 5.0 Sec.
0.4 - 2.8 Sec.
0.3 - 1.8 Sec.
0.18 - 0.9 Sec.
0.12 - 0.7 Sec.
.465
(11.8)
.889
(22.6)
.457
(11.6)
1.15 .689
(29.2) (17.5)
.303
(7.7)
SEE TERMINAL DRAWINGS
FOR DETAIL
.031 .102
(.8) (2.6)
.575
(14.6)
SEE MOUNTING
BUSHING AND
MOUNTING HARDWARE
DRAWINGS FOR DETAIL
Optional Protective Boot
Silicone rubber boot is bonded to integral alumimum nut.
Ambient Compensation Table
Ambient
Temperature
in °C
-10
0
10
20
25
30
40
50
60
Revised 04-15
www.te.com
Rating Correction Factor
3-4A Models
.70
.75
.82
.90
1.00
1.10
1.25
1.61
2.15
5-20A Models
.77
.85
.90
.95
1.00
1.05
1.15
1.25
1.40
To use this chart: Divide the breaker
rating by the correction factor to
determine the compensated rating.
Calculate the overloads in terms of
the compensated rating to use the
published trip curve.
Do not use these devices outside
their specified operating temperature
ranges.
.63 DIA.
(16.0)
.622
(15.8)
1-1423696-5
Black boot for W57 with
3/8”-24 bushing.
.70 DIA.
(17.8)
.799
(20.3)
1-1423696-6
Clear boot for W57 with
M11 X 1.0 bushing.
Dimensionsareininchesover
(millimeters)unlessotherwise
specified.
Dimensions are shown for reference
purposes only. Specifications and
availability subject to change.
USA: 1-800-522-6752
Canada: 1-905-470-4425
Mexico: 01-800-733-8926
C. America: 52-55-1106-0803
SouthAmerica:55-11-2103-6000
Hong Kong: 852-2735-1628
1
Japan: 81-44-844-8013
UK: 44-8706-080208

W57-XB1A4A10-10 Related Products

W57-XB1A4A10-10 W57-XB1A4A10-15 W57-XB6A99C10-12 W57-XB1A4A10-20
Description W57-XB1A4A10-10=CKTBKR,THERM,PB,QC.250,B W57-XB1A4A10-15=CKTBKR,THERM,P W57-XB6A99C10-12=CKTBKR,THERM,PB,QC.250 W57-XB1A4A10-20=CKTBKR,THERM,P

Technical ResourceMore

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2522  2030  1241  1955  1585  51  41  25  40  32 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号