CAUTION: Stresses above those listed in “Absolute Maximum Ratings” may cause permanent damage to the device. This is a stress only rating and operation of
the device at these or any other conditions above those indicated in the operational sections of this specification is not implied.
DC Electrical Specifications
V
CC
= 5.0V
10%;
T
A
= -40
o
C to +85
o
C
SYMBOL
V
IH
PARAMETER
Logical One
Input Voltage
V
IL
V
OH
Logical Zero Input Voltage
Logical One Output Voltage
B Outputs
A Outputs
A or B Outputs
V
OL
Logical Zero Output Voltage
B Outputs
A Outputs
I
I
IO
ICCSB
ICCOP
NOTES:
1. V
IH
is measured by applying a pulse of magnitude = V
IH(MIN)
to one data input at a time and checking the corresponding device output
for a valid logical “1” during valid input high time. Control pins (T, OE) are tested separately with all device data input pins at V
CC
-0.4
2. Typical ICCOP = 1mA/MHz of read/ cycle time. (Example: 1.0s read/write cycle time = 1mA).
Input Leakage Current
Output Leakage Current
Standby Power Supply
Current
Operating Power Supply
Current
-10.0
-10.0
-
-
0.45
0.45
10.0
10.0
10
1
V
V
A
A
A
mA/MHz
I
OL
= 20mA
I
OL
= 12mA
V
IN
= GND or V
CC
DIP Pins 9, 11
VO = GND or V
CC
, OE Š ŠV
CC
-0.5V
DIP Pins 1 - 8, 12 - 19
V
IN
= V
CC
or GND, V
CC
= 5.5V, Outputs Open
T
A
= +25
o
C, Typical (See Note 2)
3.0
3.0
V
CC
-0.4
V
V
V
I
OH
= -8mA
I
OH
= -4mA
I
OH
= -100A
MIN
2.0
2.2
-
0.8
MAX
-
UNITS
V
V
V
TEST CONDITIONS
C82C86H, I82C86H
M82C86H (Note 1)
Capacitance
SYMBOL
CIN
T
A
= +25
o
C
PARAMETER
Input Capacitance
B Inputs
A Inputs
18
14
pF
pF
Freq = 1MHz, all measurements are
referenced to device GND
TYPICAL
UNITS
TEST CONDITIONS
FN2977 Rev 2.00
June 2004
Page 3 of 6
82C86H
AC Electrical Specifications
V
CC
= 5.0V
10%; Freq = 1MHz: T
A
= -40
o
C to +85
o
C
SYMBOL
(1)
TIVOV
PARAMETER
Input to Output Delay
Inverting
Non-Inverting
(2)
(3)
(4)
(5)
(6)
(7)
TEHTV
TTVEL
TEHOZ
TELOV
TR, TF
TEHEL
Transmit/Receive Hold Time
Transmit/Receive Setup Time
Output Disable Time
Output Enable Time
Input Rise/Fall Times
Minimum Output Enable High Time
82C86H
82C86H-5
NOTES:
1. All AC parameters tested as per test circuits and definitions in timing waveforms and test load circuits. Input rise and fall times are driven at 1ns/V.
2. Input test signals must switch between V
IL
- 0.4V and V
IH
+0.4V.
3. A system limitation only when changing direction. Not a measured parameter.
30
35
-
-
ns
ns
5
5
5
10
5
10
-
30
32
-
-
30
50
20
ns
ns
ns
ns
ns
ns
ns
Notes 1, 2
Notes 1, 2
Notes 1, 2
Notes 1, 2
Notes 1, 2
Note 3
MIN
MAX
UNITS
TEST CONDITIONS
Notes 1, 2
Timing Waveform
TR, TF (6)
INPUTS
2.0V
0.8V
TEHEL (7)
OE
(1)
TIVOV
OUTPUTS
(4)
TEHOZ
VOH -0.1V
VOL +0.1V
TEHTV (2)
T
TELOV (5)
3.0V
0.45V
TTVEL (3)
NOTE: All timing measurements are made at 1.5V unless otherwise noted.