TITLE
SPECIFICATION CONTROL DRAWING
TWO CONDUCTOR CABLE, DOUBLE SHIELDED, DOUBLE JACKETED, GENERAL PURPOSE, 600 VOLT
This specification sheet forms a part of the latest issue of Raychem Specification 55PC.
JACKETS -
RADIATION-CROSSLINKED,
MODIFIED ETFE
Date
55PC6000
Revision
5-15-13
E
COMPONENT WIRES - 55PC0211
SHIELDS - TIN-COATED COPPER
CABLE CONSTRUCTION DETAILS
PART NUMBER
1/
55PC6000-24-*
55PC6000-22-*
55PC6000-20-*
55PC6000-18-*
55PC6000-16-*
55PC6000-14-*
55PC6000-12-*
CONDUCTOR
SIZE
(AWG)
24
22
20
18
16
14
12
1
st
SHIELD
SIZE
(AWG)
38
38
38
38
38
38
38
1
st
JACKET
THICKNESS ( in. )
LOWER
SPEC
LIMIT
.0050
.0055
.0055
.0055
.0060
.0060
.0060
TARGET
WALL
.0065
.0070
.0070
.0070
.0075
.0075
.0080
2
nd
SHIELD
SIZE
(AWG)
38
38
38
38
38
38
38
2
nd
JACKET
THICKNESS ( in. )
LOWER
SPEC
LIMIT
.0055
.0055
.0060
.0060
.0060
.0060
.0065
TARGET
WALL
.0070
.0070
.0075
.0075
.0075
.0080
.0085
OUTSIDE DIAMETER
( in. )
LOWER
SPEC
LIMIT
.136
.148
.166
.185
.201
.232
.271
TARGET
VALUE
.141
.154
.172
.191
.207
.238
.278
UPPER
SPEC
LIMIT
.147
.160
.178
.197
.213
.245
.285
WEIGHT
( lbs/1000 ft. )
TARGET
VALUE
16.70
20.12
25.22
31.89
37.45
50.30
69.20
UPPER
SPEC
LIMIT
17.35
20.84
26.01
32.82
38.46
51.48
70.68
Users should evaluate the suitability of this product for their application. Specifications are subject to change without notice.
Tyco Electronics Corporation also reserves the right to make changes in materials or processing, which do not affect compliance with any specification, without notification to Buyer.
1/
COLORS AND COLOR CODE DESIGNATORS SHALL BE IN ACCORDANCE WITH MIL-STD-681. HOWEVER, DUE TO LENGTH LIMITATIONS OF THE RAYCHEM PART NUMBER,
AN ALTERNATIVE COLOR CODE MAY REPLACE MIL-STD-681 COLOR CODE DESIGNATORS. (EXAMPLE: “901/902...” MAY BE REPLACED BY “Axxx”.) OTHER CODES
AND SUFFIXES MAY BE ADDED TO THE PART NUMBER, AS NECESSARY, TO CAPTURE ANY ADDITIONAL REQUIREMENTS IMPOSED BY THE PURCHASE ORDER.
Raychem, TE Connectivity, TE connectivity (logo) and TE (logo) are trademarks.
Raychem Wire & Cable
501 Oakside Avenue
Redwood City, CA 94063-3800
Phone: 1-800-227-8816
Fax: 1-650-361-6297
© 2006-2013 Tyco Electronics Corporation,. All rights reserved.
Page 1 of 2
DIMENSIONS ARE IN INCHES, AND UNLESS OTHERWISE DESIGNATED ARE NOMINAL.
THIS SPECIFICATION SHEET TAKES PRECEDENCE OVER DOCUMENTS REFERENCED HEREIN.
REFERENCED DOCUMENTS SHALL BE OF THE ISSUE IN EFFECT ON DATE OF INVITATION FOR BID.
Revision
SCD
SPECIFICATION CONTROL DRAWING
CABLE RATINGS AND ADDITIONAL REQUIREMENTS
TEMPERATURE RATING: 150°C
Maximum continuous conductor temperature
VOLTAGE RATING: 600 volts (rms) at sea level
CROSSLINK VERIFICATION: 300 ± 3°C for 1 hour
DIELECTRIC WITHSTAND:
1500 volts (rms), 60 Hz conductor to conductor and shield
500 volts (rms), 60 Hz shield to shield
JACKET COLOR: White preferred
JACKET ELONGATION AND TENSILE STRENGTH:
Elongation, 50% (minimum) (each)
Tensile Strength, 5000 lbf/in² (minimum) (each)
JACKET FLAWS:
Spark Test, 1000 volts (rms)
Impulse Dielectric Test, 6.0 kV (peak)
SHIELD COVERAGE:
85% (minimum) (each)
VOLTAGE WITHSTAND (Post Environmental):
1000 volts (rms), 60 Hz, 1 minute
Page 2 of 2
E
55PC6000
CABLE IDENTIFICATION: Mark outer jacket surface in a contrasting color at 12 inch (nominal)
intervals as follows: " 55PC6000-AWG ** "
** = Applicable Manufacturer CAGE code as follows:
06090 = Menlo Park, CA
SU473 = Tijuana, MX
PART NUMBER:
The "*" in the part numbers on page 1 shall be replaced by color code designators
with a slash separating the component wire colors and a dash separating the component
wire colors from the inner jacket color and a dash separating the inner jacket color from the
outer jacket color.
1/
Example: AWG 22, red and blue component wires; white inner jacket and white outer jacket:
55PC6000-22-2/6-9-9
1/
See footer section on page 1