SPECIFICATION CONTROL DRAWING
TITLE
55PC0812
Date
WIRE, RADIATION-CROSSLINKED, MODIFIED ETFE-INSULATED, NORMAL WEIGHT, GENERAL PURPOSE, 600 VOLT
This specification sheet forms a part of the latest issue of Raychem Specification 55PC.
CONDUCTOR - SILVER-COATED COPPER
INSULATION - RADIATION - CROSSLINKED,
MODIFIED ETFE
1-17-12
Revision
D
CONSTRUCTION DETAILS
CONDUCTOR DIAMETER
(in.)
LOWER
SPEC
LIMIT
.0175
.0225
.0285
.0365
.0452
.0514
.0644
.0825
.1050
.158
.198
.250
.320
.360
.395
.440
TARGET
VALUE
.0183
.0233
.0293
.0375
.0464
.0527
.0659
.0845
.1070
.163
.205
.260
.330
.370
.415
.462
UPPER
SPEC
LIMIT
.0191
.0241
.0301
.0385
.0476
.0538
.0674
.0865
.1090
.169
.212
.268
.340
.380
.425
.475
FINISHED WIRE
MAXIMUM
RESISTANCE
AT 20°C
(ohms/1000 ft.)
38.4
24.3
15.1
9.19
5.79
4.52
2.88
1.90
1.19
.658
.418
.264
.170
.139
.108
.085
DIAMETER
(in.)
LOWER
SPEC
LIMIT
.0366
.0416
.0476
.0561
.0659
.0737
.0896
.1076
.1290
.188
.233
.300
.370
.408
.449
.505
TARGET
VALUE
.0385
.0435
.0495
.0580
.0680
.0760
.0920
.1105
.1330
.196
.242
.311
.383
.423
.466
.525
UPPER
SPEC
LIMIT
.0404
.0454
.0514
.0599
.0701
.0783
.0944
.1134
.1370
.203
.251
.322
.397
.438
.483
.545
WEIGHT
(lbs/1000 ft.)
TARGET
VALUE
1.55
2.18
3.12
4.64
6.94
8.80
13.50
20.45
31.73
56.8
89.7
146.
227.
278.
343.
450.
UPPER
SPEC
LIMIT
1.70
2.34
3.30
4.85
7.27
9.17
13.99
21.08
32.78
59.9
94.7
154.
240.
288.
366.
481.
PART
NUMBER
1/
WIRE
SIZE
(AWG)
CONDUCTOR
STRANDING
(number x AWG)
55PC0812-26-*
55PC0812-24-*
55PC0812-22-*
55PC0812-20-*
55PC0812-18-*
55PC0812-16-*
55PC0812-14-*
55PC0812-12-*
55PC0812-10-*
55PC0812-8-*
55PC0812-6-*
55PC0812-4-*
55PC0812-2-*
55PC0812-1-*
55PC0812-0-*
55PC0812-00-*
26
24
22
20
18
16
14
12
10
8
6
4
2
1
0
00
19 x 38
19 x 36
19 x 34
19 x 32
19 x 30
19 x 29
19 x 27
37 x 28
37 x 26
133 x 29
133 x 27
133 x 25
665 x 30
817 x 30
1045 x 30
1330 x 30
Users should evaluate the suitability of this product for their application. Specifications are subject to change without notice.
Tyco Electronics Corporation also reserves the right to make changes in materials or processing, which do not affect compliance with any specification, without notification to Buyer.
1/
COLORS AND COLOR CODE DESIGNATORS SHALL BE IN ACCORDANCE WITH MIL-STD-681. OTHER CODES AND SUFFIXES MAY BE
ADDED TO THE PART NUMBER. AS NECESSARY, TO CAPTURE ANY ADDITIONAL REQUIREMENTS IMPOSED BY THE PURCHASE ORDER.
Raychem, TE Connectivity, TE connectivity (logo) and TE (logo) are trademarks.
Raychem Wire & Cable
501 Oakside Avenue
Redwood City, CA 94063-3800
Phone: 1-800-227-8816
Fax: 1-650-361-6297
© 2009-2012 Tyco Electronics Corporation,. All rights reserved.
Page 1 of 2
DIMENSIONS ARE IN INCHES, AND UNLESS OTHERWISE DESIGNATED ARE NOMINAL.
THIS SPECIFICATION SHEET TAKES PRECEDENCE OVER DOCUMENTS REFERENCED HEREIN.
REFERENCED DOCUMENTS SHALL BE OF THE ISSUE IN EFFECT ON DATE OF INVITATION FOR BID.
Revision
SCD
SPECIFICATION CONTROL DRAWING
Page 2 of 2
D
55PC0812
WIRE RATINGS AND ADDITIONAL REQUIREMENTS
TEMPERATURE RATING: 200°C
Maximum continuous conductor temperature
VOLTAGE RATING: 600 volts (rms) at sea level
COLOR: White preferred
CROSSLINK VERIFICATION: 300 ± 3°C for 1 hour
IDENTIFICATION AND COLOR STRIPING DURABILITY:
125 cycles (250 strokes) (minimum). 500 g weight.
INSULATION ELONGATION AND TENSILE STRENGTH:
Total Insulation,
Elongation, 50% (minimum)
Tensile Strength, 5000 lbf/in² (minimum)
INSULATION FLAWS:
Spark Test, 3.0 kV (rms)
Impulse Dielectric Test, 8.0 kV (peak)
INSULATION THICKNESS: .010 in. (nominal) total insulation
SHRINKAGE: 230 ± 3°C for 1 hour, 0.125 inch (maximum) in 12 inches.
VOLTAGE WITHSTAND (Post Environmental): 2500 volts (rms)
PART NUMBER:
The “*” in the part numbers on page 1 shall be replaced by a color code designator,
1/
Example: AWG 22, white: 55PC0812-22-9
AWG 22, white with black stripe: 55PC0812-22-90
1/
See footer section on page 1