Parameter NameAttribute value
Wall typesingle
Product SeriesRNF-100
Voltage (max) (kV).6
coloryellow
Shrinkage2:1
MaterialIrradiated modified polyolefin
flexibilityFlexible
Fluid typewater, gasoline, lubricating oil, hydraulic oil
Expand inner diameter (minimum value)3.2 mm [ .126 in ]
Recovered inner diameter (maximum value)1.6 mm [ .063 in ]
Recovered wall thickness (nominal).5 mm [ .02 in ]
cutting length1220 mm [ 48.031 in ]
Recovered wall thickness (tolerance).2 mm [ .008 in ]
Shrinkage temperature (min) (°C)95
Resistanttension, friction, mechanical damage, liquid
Operating temperature range (°C)-55 – 135
Flammabilityignition retardation
Shrinkage temperature (°C)121
fluid resistancesplash proof
Applicable areaglobal, global
Encapsulation methodPaste
Product sourceCzech Republic
Low outgassingno
RAYCHEM Tubing Products
RNF-100
Flexible, Flame-Retardant,
General Purpose,
Polyolefin Tubing
Product Facts
2:1 shrink ratio
I
Superior abrasion and
solvent resistance when
compared with that of many
flexible, general purpose
polyolefin tubings
I
Excellent physical,
chemical, and electrical
properties that meet or
exceed industrial and
military standards for highly
reliable, general purpose
tubing
I
Flexible; conforms to
irregular shapes
I
Flame-retardant (colors
only)
I
Wide range of sizes and
colors
I
RoHS compliant
I
1
Heat-shrinkable Tubing
Applications
Designed to provide superior
mechanical (abrasion, cut-
through, and strain relief),
thermal, and fluid-resistance
performance in demanding
environments. Widely used
to provide insulation and
strain relief of wire termina-
tions and connections. Used
for jacketing wire bundles
and light-duty harnesses
where superior abrasion
resistance is a plus. Also
used to identify and color-
code electrical connections
and wire bundles.
Installation
Minimum shrink
temperature: 95°C [203°F]
Minimum full recovery
temperature: 121°C [250°F]
Operating Temperature Range
-55°C to 135°C
[-67°F to 275°F]
Specifications/Approvals
Series
RNF-100 Type 1
(colors)
RNF-100 Type 2
(clear)
UL
E35586
600 V, 125°C
CSA
®
Military
AMS-DTL-23053/5*,
Class 1
Def. Stan. 59-97 Type 2B
AMS-DTL-23053/5*,
Class 2
VG 95343 Pt 5 Type B
Industry
VDE 0341 Pt 9005
Type A and B
Raychem
RT-350, Type 1
RK-6001
RT-350, Type 2
RK-6001
LR31929
600 V, 125°C
*Formerly MIL-I-23053/5 and MIL-DTL-23053/5.
Available in:
Americas
I
Europe
I
Asia Pacific
I
1-89
9-1773447-9
CIS WR 08/2011
te.com
Dimensions are in inches and
millimeters unless otherwise
specified. Values in brackets
are metric equivalents.
Dimensions are shown for
reference purposes only.
Specifications subject
to change.
USA: 1-800-522-6752
Canada: 1-905-475-6222
Mexico: 52-55-1106-0800
L. & S. America: 54-11-4733-2200
Germany: 49-6251-133-1999
China: 86-400-820-6015
Japan: 81-44-844-8013
UK: 44-800-267-666
Can vxworks compile a dynamic library, that is, can it generate a .so file?
Can vxworks compile a dynamic library, that is, can it generate a .so file? I am using two compilation environments, tornado2.2 and Wind River. Previously, we compiled libraries by writing static libr...
zyjnh005 Real-time operating system RTOS
Strain Gauges
A dynamic force is loaded on one end of the cantilever beam, and a strain gauge is used to measure the strain of the cantilever beam. To ensure that the strain gauge can work normally, what is the max...
a问问 Sensor
Discussion on AC and DC conversion issues
I hope all the power experts will think about the four basic power conversion problems: DC to DC, AC to DC, DC to AC, and AC to AC, including how to convert, what devices or components to use for conv...
piggyfeng Power technology
51 MCU floating point calculation error problem
I would like to ask, after using stc89c52 to do floating point calculations, there is sometimes an error of 0.01 when taking 2 decimal places. What is the accuracy of floating point calculations of si...
zzxuzz 51mcu
MSP430F5529 Power Management Module
Power management and monitoring is a very complex part that is difficult to master. It not only involves the selection of source mode, but also involves complex interrupts and how to handle interrupts...
Jacktang Microcontroller MCU
I want an expert to help me write an intelligent light-controlled street lamp system based on 51 single-chip microcomputer
RT, it would be better if there is a circuit diagram, thanks in advance. . If you have any, please send them to tianya3849@163.com :Cry:...
tianya3849 51mcu

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 106  1068  1845  1069  2748  3  22  38  56  53 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号