EEWORLDEEWORLDEEWORLD

Part Number

Search

2115-N3-36-30

Description
30 CONTACT(S), FEMALE, RIGHT ANGLE SINGLE PART CARD EDGE CONN, SOLDER
CategoryThe connector    The connector   
File Size151KB,2 Pages
ManufacturerECS
Websitehttp://www.ecsxtal.com/
Download Datasheet Parametric View All

2115-N3-36-30 Overview

30 CONTACT(S), FEMALE, RIGHT ANGLE SINGLE PART CARD EDGE CONN, SOLDER

2115-N3-36-30 Parametric

Parameter NameAttribute value
MakerECS
Reach Compliance Codeunknown
ECCN codeEAR99
Connector typeCARD EDGE CONNECTOR
Contact point genderFEMALE
DIN complianceNO
Filter functionNO
IEC complianceNO
MIL complianceNO
Mixed contactsNO
Installation methodRIGHT ANGLE
Installation typeBOARD
Number of rows loaded2
OptionsGENERAL PURPOSE
Terminal pitch3.175 mm
Termination typeSOLDER
Total number of contacts30
UL Flammability Code94V-0
Base Number Matches1
CC
S
2100 Series Card Edge Connector
.125” X .250” Contact Spacing
Features
Extra large chamfered entry
Conforms to Bell-core spec TR-TSY-00078
Extended card scoops available
Replaceable contacts
Molded in polarization available between
contact, or on contact position.
• De-population of contacts per
customer specification.
• Available in selective gold plate at contact point
• Many other custom options available, including,
but not limited to:
• Single or Both Ends Open
• Shorting Contacts
Specifications
Insulator Material: Glass filled polyester, type PBT,
94 V-O, UL Rated.
Contact Material: Phosphor Bronze Alloy
Contact Plating: Gold and/or Tin over .000050” Nickel,
(See Contact Plating Options).
Current Rating:
3 amp at 30°C
Contact Resistance:
Contact to Daughter Card:
10 m
W
max.
Insulation Resistance:
5000 M
W
min.
Dielectric Withstand Voltage:
1500 V AC
Daughter Board Insertion Force:
16 oz max. per contact pair
when tested with a .071” thick
gage.
Daughter Board Withdrawal Force:
1 oz min. per contact pair
when tested with a .054” thick
gage.
Operating Temperature:
-54
B
C to +125
B
C
R
C
NO. OF CONTACTS
R
A
Recognized under the recognized component
Program of Underwriters Laboratories, Inc.
File Numbers: E146967 and E176234
POS. / CONTACTS
06/12
10/20
12/24
16/32
18/36
20/40
22/44
25/50
28/56
30/60
36/72
38/76
40/80
43/86
50/100
51/102
56/112
60/120
A
1.011 [25.68]
1.511 [38.38]
1.761 [44.73]
2.261 [57.43]
2.511 [63.78]
2.761 [70.13]
3.011 [76.48]
3.386 [86.00]
3.761 [95.53]
4.011 [101.88]
4.761 [120.93]
5.011 [127.28]
5.261 [133.63]
5.626 [143.15]
6.511 [165.38]
6.636 [168.55]
7.261 [184.43]
7.761 [197.13]
B
0.875 [22.23]
1.375 [34.93]
1.625 [41.28]
2.125 [53.98]
2.375 [60.33]
2.625 [66.68]
2.875 [73.03]
3.250 [82.55]
3.625 [92.08]
3.875 [98.43]
4.625 [117.48]
4.875 [123.83]
5.125 [130.18]
5.500 [139.70]
6.375 [161.93]
6.500 [165.10]
7.125 [180.98]
7.625 [193.68]
C
0.625 [15.88]
1.125 [28.58]
1.375 [34.93]
1.875 [47.63]
2.125 [53.98]
2.375 [60.33]
2.625 [66.68]
3.000 [76.20]
3.375 [85.73]
3.625 [92.08]
4.375 [111.13]
4.625 [117.48]
4.875 [123.83]
5.250 [133.35]
6.125 [155.58]
6.250 [158.75]
6.875 [174.63]
7.375 [187.33]
Dimensions are in inch [mm]
For reference only, can go 1 through 60 positions.
MOUNTING STYLE
.250
[6.35]
.180
[4.57]
.610
[15.49]
.250
[6.35]
1
= Clearance Hole
2
= #4-40 Threaded Insert
3
= Flush Mount
4
= #4-40 Threaded Insert
5
= No Mounting Ear
6
= Side Mounting
WWW.ECSCONN.COM
EEWORLD University Hall----Texas Instruments Automotive Advanced Driver Assistance System ADAS Solution Seminar
Texas Instruments Automotive Advanced Driver Assistance System ADAS Solution Seminar : https://training.eeworld.com.cn/course/4170...
hi5 Automotive Electronics
Senior: Could you please tell me the relationship between feedback circuit type and two-port network?
Senior: Why should voltage and current negative feedback correspond to the y-model network circuit? Can you analyze it from the circuit? I don’t understand the relationship between them? Or can you po...
tercel Analog electronics
[Flooding] IAR interrupt flags and warnings
Do I need to manually clear the interrupt flag when IAR's C430 interrupt exits?The microcontrollers I used before all required clearing the interrupt flag before returning from the interrupt.My progra...
梦里飘 Microcontroller MCU
Portable Oscilloscope Group is established, calling for interested parties to join
Why choose an oscilloscope? 1. As a person engaged in electronics, the importance of an oscilloscope is self-evident. Although the price of an oscilloscope is more affordable than that of 3 or 5 years...
ltbytyn stm32/stm8
Ask for solutions for ultrasonic data acquisition and fault diagnosis
This system is mainly used to collect ultrasonic data and analyze the waveform to determine the fault point in the material in real time. Now I am considering using arm9, because I also need to displa...
zhuxiaoying Embedded System
Where can I find BMS training?
[b]Where can I get BMS training? [/b]...
12594646 Automotive Electronics

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1662  2828  783  2176  2105  34  57  16  44  43 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号