EEWORLDEEWORLDEEWORLD

Part Number

Search

232232907109

Description
RESISTOR, WIRE WOUND, 7W, 5%, 80ppm, 10ohm, THROUGH HOLE MOUNT, AXIAL LEADED, ROHS COMPLIANT
CategoryPassive components    The resistor   
File Size171KB,11 Pages
ManufacturerVishay
Websitehttp://www.vishay.com
Environmental Compliance
Download Datasheet Parametric View All

232232907109 Overview

RESISTOR, WIRE WOUND, 7W, 5%, 80ppm, 10ohm, THROUGH HOLE MOUNT, AXIAL LEADED, ROHS COMPLIANT

232232907109 Parametric

Parameter NameAttribute value
Is it Rohs certified?conform to
MakerVishay
package instruction,
Reach Compliance Codeunknown
ECCN codeEAR99
JESD-609 codee3
Manufacturer's serial numberAC07
Installation featuresTHROUGH HOLE MOUNT
Number of terminals2
Maximum operating temperature200 °C
Minimum operating temperature-40 °C
Package shapeTUBULAR PACKAGE
method of packingAMMO PACK
Rated power dissipation(P)7 W
Rated temperature40 °C
resistance10 Ω
Resistor typeFIXED RESISTOR
surface mountNO
technologyWIRE WOUND
Temperature Coefficient80 ppm/°C
Terminal surfaceMatte Tin (Sn)
Terminal shapeWIRE
Tolerance5%
Base Number Matches1
AC.. Series
Vishay Draloric
Cemented Wirewound Resistors
FEATURES
All welded construction
Ceramic core
Non-flammable cement coating
Tinned copper-clad iron leads
(for axial parts)
High power dissipation in small volume
Ideal for pulse application
Lead (Pb)-free
Compliant to RoHS directive 2002/95/EC
STANDARD ELECTRICAL SPECIFICATIONS
POWER RATING
MODEL
AC01
AC03
(1)
AC04
AC05
AC07
AC10
P
40 °C
1W
3W
4W
5W
7W
10 W
P
70 °C
0.9 W
2.5 W
3.5 W
4.7 W
5.8 W
8.4 W
LIMITING
VOLTAGE
U
max.
P
x
R
P
P
P
P
P
x
x
x
x
x
R
R
R
R
R
RESISTANCE RANGE
(2)
TCR =
TCR =
TCR =
- 10 ... - 80 ppm/K 100 ... 180 ppm/K
± 100 ppm/K
0.10
Ω
to 33
Ω
0.10
Ω
to 390
Ω
0.10
Ω
to 620
Ω
0.10
Ω
to 910
Ω
0.10
Ω
to 1.5 kΩ
0.22
Ω
to 560
Ω
36
Ω
to 2.4 kΩ
430
Ω
to 3.3 kΩ
680
Ω
to 6.8 kΩ
1 kΩ to 10 kΩ
1.6 kΩ to 15 kΩ
620
Ω
to 27 kΩ
-
3.6 kΩ - 5.1 kΩ
-
-
-
-
TOLERANCE
±5%
±5%
±5%
±5%
±5%
±5%
Note
(1)
AC03 WSZ:
P
40 °C
= 1.8 W;
P
70 °C
= 1.5 W
PART NUMBER AND PRODUCT DESCRIPTION
Part Number: AC03000001509JAC00
A
C
0
3
0
0
0
0
0
1
5
0
9
J
A
C
0
0
MODEL
AC01000
= AC01
AC03000
= AC03
AC04000
= AC04
AC05000
= AC05
AC07000
= AC07
AC10000
= AC10
VARIANT
0
= Neutral
1
= RT
2
= SWI =
Special winding
(3)
3
= DK SP 20 mm
(4)
4
= DK LP 33 mm
(4)
5
= DK LP 17.8 mm
(4)
6
= NI = Non inductive
7
= DK LP 25.4 mm
(4)
9
= WSZ 6720
8
= DK SP 25.4 mm
Z
= Value overflow
(Special)
C
= E/K 25.4 mm
(4)
TCR/MATERIAL
0
= Standard
VALUE
3 digit value
1 digit
multiplier
MULTIPLIER
7
= *10
-3
8
= *10
-2
9
= *10
-1
0
= *10
0
1
= *10
1
2
= *10
2
5
= 10
-4
TOLERANCE PACKAGING
CODE
CODE
J
= ± 5.0 %
(See
Packaging
table)
SPECIAL
The 5 digit BV number will be
encoded using a 36
character code. This code
contains numbers 0...9 and
letters A...Z
(36 characters total) and
allows to encode at least 46
655 five digit BV numbers.
00
= Standard
Product Description: AC03 15R 5 % AC
AC03
MODEL
(5)
(2)
(3)
15R
VALUE
(5)
5%
TOLERANCE CODE
(5)
AC
PACKAGING
DESCRIPTION
(6)
Notes
Resistance value to be selected for ± 10 % tolerance from E12 and for ± 5 % from E24
Special winding on request
(4)
Other dimensions and variants on request
(5)
See “Part Number and Product Description”
(6)
See “Packaging Table”
** Please see document “Vishay Green and Halogen-Free Definitions (5-2008)”:
www.vishay.com/doc?99902
www.vishay.com
22
For technical questions, contact:
ww1resistors@vishay.com
Document Number: 28730
Revision: 27-Oct-09
How to install the lens, pan/tilt, decoder, and converter
Zoom lens or zoom camera (all-in-one) can realize the change of focal length, aperture, and near and far monitoring screen; PTZ can realize the change of monitoring position such as left, right, up, d...
clark Industrial Control Electronics
Friends who want to download the e-book, please look at the pinned information
Now it has been changed to be downloaded to the mailbox, thank you for your support!!!...
totopper Industrial Control Electronics
After GD32F303 SPI is powered on again, the CLK clock signal IO is not output, but the simulation is normal.
Problem: After GD32F303 SPI is powered on again, the CLK clock signal IO is not output, but the simulation is normal.My configuration is as follows: Use SPI0, IO remappingFigure 1 This is the normal t...
sinsnsns GD32 MCU
[Sample] + Optical heart rate monitor reference design supporting BLE connection
[i=s]This post was last edited by Qiangzi00001 on 2014-7-28 01:08[/i] [color=#555555]Texas Instruments (TI) provides users with the service of applying for semiconductor samples[/color][color=#555555]...
强仔00001 TI Technology Forum
SL200 MCU learning board, hardware simulation shows target dll has been cancelled debugger aborted
What is the problem with the hardware emulation "target dll has been cancelled debugger aborted"? Before this, there was a window similar to "connection to target system loss try again .............. ...
auto0811 Embedded System

Technical ResourceMore

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2915  882  186  2898  2565  59  18  4  52  51 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号