EMC filters
2-line filters
IEC inlet filters
Series/Type:
Date:
B84773
August 2016
© EPCOS AG 2016. Reproduction, publication and dissemination of this publication, enclosures hereto and the
information contained therein without EPCOS' prior express consent is prohibited.
EPCOS AG is a TDK Group Company.
2-line filters
IEC inlet filters
B84773
Power line filters for 1-phase systems
Rated voltage V
R
: 250 V AC/DC
Rated current I
R
: 1 A to 10 A
Construction
2-line filters with IEC connector and fuse holder
Appliance connector according to IEC 60320-1
Fuse holder for 2 fuses
∅
5
×
20 mm
(delivery without fuse)
Metal case
Versions
Standard version (B84773A*)
Medical version with negligibly low leakage current
(B84773M*)
Features
Easy to install
Compact design
Cost optimized construction
Degree of protection front side with power plug: IP 40
1)
ENEC, UL and cUL approval
Typical applications
Switch-mode power supplies for
industrial electronics
telecom systems
data systems
DC applications
Measuring instruments
Medical equipment
Terminals
Line side: IEC connectors C14 according to IEC 60320-1
Load side: Tab connectors
Marking
Marking on component:
Manufacturer's logo, ordering code, rated voltage, rated
current, rated temperature, climatic category, date code,
approvals
Minimum data on packaging:
Manufacturer's logo, ordering code, quantity, date code
1) According to IEC 60529
Please read
Cautions and warnings
and
Important notes
at the end of this document.
Page 2 of 15
2-line filters
IEC inlet filters
B84773
Typical circuit diagram of B84773A*
(standard version)
Typical circuit diagram of B84773M*
(medical version)
Please read
Cautions and warnings
and
Important notes
at the end of this document.
Page 3 of 15
2-line filters
IEC inlet filters
B84773
Technical data and measuring conditions
Rated voltage V
R
Rated current I
R
Test voltage V
test
250 V AC (50/60 Hz) / 250 V DC
Referred to 40
°C
rated temperature
B84773A*: 760 V AC, 2 s (line/line)
B84773M*: 1700 V DC, 2 s (line/line)
B84773A*: 2000 V AC, 2 s (lines/case)
B84773M*: 2500 V AC, 2 s (lines/case)
At V
R
and 50 Hz
25/085/21 ( 25
°C/+85 °C/21
days damp heat test)
IEC 60939, UL 1283, CSA C22.2 No.8
Leakage current l
LK
Climatic category (IEC 60068-1)
Approvals
Characteristics and ordering codes
I
R
A
C
R
X2
μF
C
R
Y2
pF
L
R
mH
2
×
5.4
2
×
5.4
2
×
2.7
2
×
2.7
2
×
1.1
2
×
1.1
2
×
0.3
2
×
0.3
2
×
0.2
2
×
0.2
I
LK1)
mA
0.173
0
0.173
0
0.173
0
0.173
0
0.173
0
R
bleed
Approx. Ordering code
weight
MΩ g
1
1
1
1
1
1
1
1
1
1
55
55
55
55
55
55
55
55
75
75
B84773A0001A000
B84773M0001A000
B84773A0002A000
B84773M0002A000
B84773A0004A000
B84773M0004A000
B84773A0006A000
B84773M0006A000
B84773A0010A000
B84773M0010A000
Approvals
V
R
= 250 V AC/DC
1 1
×
0.1 2
×
2200
1 1
×
0.1
2 1
×
0.1 2
×
2200
2 1
×
0.1
4 1
×
0.1 2
×
2200
4 1
×
0.1
6 1
×
0.1 2
×
2200
6 1
×
0.1
10 1
×
0.1 2
×
2200
10 1
×
0.1
×
= Approval granted
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
1) Calculation according to IEC 60939-1, annex A, at rated voltage and 50 Hz. In practice are up to double values to be expected due to
the insulation resistance values of the used ceramic capacitors. For the medical version results computationally the value 0. In practice
are values 1 ... 2
μA
to be expected due to the insulation resistance values of the used materials.
Please read
Cautions and warnings
and
Important notes
at the end of this document.
Page 4 of 15
2-line filters
IEC inlet filters
B84773
Dimensional drawing
General tolerances according to ISO 2768 cL
Dimensions in mm
Safety Notices
fuses
All safety rules for working with electricity must be observed.
Fuses may only be changed when they are not under voltage and by a qualified electrician or
technician.
The fuse holder must be closed before connecting the device to the mains.
The person responsible for the system must select a suitable fuse (not included with the
original product shipment), taking into account the specifications of both the filter and the
systems.
Please read
Cautions and warnings
and
Important notes
at the end of this document.
Page 5 of 15