EEWORLDEEWORLDEEWORLD

Part Number

Search

B59042A1120A110

Description
Overcurrent protection in MDF modules
CategoryPassive components    The resistor   
File Size60KB,4 Pages
ManufacturerEPCOS (TDK)
Environmental Compliance
Download Datasheet Parametric Compare View All

B59042A1120A110 Overview

Overcurrent protection in MDF modules

B59042A1120A110 Parametric

Parameter NameAttribute value
Is it lead-free?Lead free
Is it Rohs certified?conform to
MakerEPCOS (TDK)
package instruction,
Reach Compliance Codecompli
ECCN codeEAR99
JESD-609 codee4
Manufacturer's serial numberB59042
Installation featuresSURFACE MOUNT
Number of terminals2
Maximum operating temperature60 °C
Minimum operating temperature
Package shapeDISK PACKAGE
method of packingTRAY
Rated (AC) voltage (URac)265 V
resistance10 Ω
Resistor typePTC THERMISTOR
surface mountYES
Terminal surfaceSilver (Ag)
Thermistor ApplicationsOVERLOAD PROTECTION
Tolerance20%
Telecom
MDF Applications, Metallized Round Disks
Applications
I
Overcurrent protection in MDF modules
B59***
A 1***, A**
Features
I
Compliant with ITU-T K20, K21, K45
– basic level lightning surges (10/700 µs)
– basic level power induction (600 V, 1 A, 0,2 s)
– power contact criteria A/B (230 V, 15 min.)
I
Suitable for continous connection to mains voltages
of 110/230 VAC in tripped (high ohmic) condition
I
Narrow resistance tolerance
Options
I
Alternative tolerances and resistances on request
Delivery mode
I
Packed in deep-drawn trays
Dimensional drawing
b
Termination
s
TPT0787-V-E
Dimensions (mm)
Type
A 1048
A 1037
A 1042
A 1610
A 1012
b
max
7,7
6,6
8,2
10,2
5,9
s
max
5,0
1,5
2,0
2,0
2,0
Type
A 1041
A 48
A 34
A 12
A 37
b
max
8,0
7,7
6,6
5,9
5,9
s
max
2,0
5,0
1,5
2,0
2,0
110
10/02

B59042A1120A110 Related Products

B59042A1120A110 B59048A1080B110 B59610A1120B110 B59048A0080B110 B59041A1120A110 B59034A0120B110 B59012A0080B110 B59037A0090B110 B59012A1080B110
Description Overcurrent protection in MDF modules Overcurrent protection in MDF modules Overcurrent protection in MDF modules Overcurrent protection in MDF modules Overcurrent protection in MDF modules Overcurrent protection in MDF modules Overcurrent protection in MDF modules Overcurrent protection in MDF modules Overcurrent protection in MDF modules
Is it Rohs certified? conform to conform to conform to conform to conform to conform to conform to conform to conform to
Maker EPCOS (TDK) EPCOS (TDK) EPCOS (TDK) EPCOS (TDK) EPCOS (TDK) EPCOS (TDK) EPCOS (TDK) EPCOS (TDK) EPCOS (TDK)
Reach Compliance Code compli compli compli compli compli compli compli compli compli
JESD-609 code e4 e4 e4 e4 e4 e4 e4 e4 e4
Installation features SURFACE MOUNT SURFACE MOUNT CHASSIS MOUNT CHASSIS MOUNT SURFACE MOUNT SURFACE MOUNT CHASSIS MOUNT SURFACE MOUNT SURFACE MOUNT
Number of terminals 2 2 2 2 2 2 2 2 2
Maximum operating temperature 60 °C 60 °C 70 °C 70 °C 60 °C 60 °C 70 °C 60 °C 60 °C
Package shape DISK PACKAGE DISK PACKAGE CYLINDRICAL PACKAGE CYLINDRICAL PACKAGE DISK PACKAGE DISK PACKAGE CYLINDRICAL PACKAGE DISK PACKAGE DISK PACKAGE
method of packing TRAY TRAY TRAY, BLISTER TRAY, BLISTER TRAY TRAY TRAY, BLISTER TRAY TRAY
Rated (AC) voltage (URac) 265 V 265 V 230 V 230 V 265 V 265 V 230 V 265 V 265 V
resistance 10 Ω 6 Ω 0.1 Ω 0.2 Ω 25 Ω 10 Ω 0.25 Ω 18 Ω 12 Ω
Resistor type PTC THERMISTOR PTC THERMISTOR PTC THERMISTOR PTC THERMISTOR PTC THERMISTOR PTC THERMISTOR PTC THERMISTOR PTC THERMISTOR PTC THERMISTOR
surface mount YES YES NO NO YES YES NO YES YES
Terminal surface Silver (Ag) Silver (Ag) Silver (Ag) Silver (Ag) Silver (Ag) Silver (Ag) Silver (Ag) Silver (Ag) Silver (Ag)
Thermistor Applications OVERLOAD PROTECTION OVERLOAD PROTECTION OVERLOAD PROTECTION OVERLOAD PROTECTION OVERLOAD PROTECTION OVERLOAD PROTECTION OVERLOAD PROTECTION OVERLOAD PROTECTION OVERLOAD PROTECTION
Tolerance 20% 20% 20% 10% 20% 20% 15% 20% 20%
Is it lead-free? Lead free Lead free - Lead free Lead free Lead free - Lead free Lead free
ECCN code EAR99 - EAR99 EAR99 - EAR99 EAR99 EAR99 EAR99
Manufacturer's serial number B59042 B59048 B59610 B59048 B59041 - B59012 B59037 B59012
Study on digital filter to filter out power frequency and harmonic interference in electronic measurement system
Abstract: In electronic measurement, power frequency is one of the main sources of noise interference. If it is not filtered out, it will greatly affect the measurement accuracy. The traditional analo...
fighting Test/Measurement
How to enable the device's code scanning function when developing software for MOTOROLA MC1000 using VS2008
How to enable the code scanning function of the device when developing software for MOTOROLA MC1000 with VS2008? I recently developed a WINDOWS CE .NET 4.2 program with VS.NET2008 and it runs normally...
eagletie Embedded System
Detailed explanation of Zigbee networking principle
Building a complete Zigbee mesh network includes two steps: network initialization and node joining the network. Node joining the network includes two steps: joining the network by connecting to the c...
灞波儿奔 Wireless Connectivity
ZigBee Help Post
Hello everyone, I would like to ask how to solve the problem that the network address of the ZigBee node changes after powering off and then back on. I am a novice, please explain in detail...
mgf_xuexi RF/Wirelessly
How to make the decoder output only have one high level and the rest are low levels?
There is no decoder chip with only one output that is high....
reohad Integrated technical exchanges
AD6 PCB Circuit Design
[font=SimSun][size=10.5pt]This chapter introduces some basic concepts of printed circuit board (PCB) design, such as circuit boards, wires, component packaging, multilayer boards, etc., and introduces...
xiaoxin1 PCB Design

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 576  2143  1750  105  2824  12  44  36  3  57 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号