EEWORLDEEWORLDEEWORLD

Part Number

Search

6QDP-016-03.8-TBR-TBL-3-S

Description
Interconnection Device, ROHS COMPLIANT
CategoryThe connector    The connector   
File Size655KB,1 Pages
ManufacturerSAMTEC
Websitehttp://www.samtec.com/
Environmental Compliance
Download Datasheet Parametric View All

6QDP-016-03.8-TBR-TBL-3-S Overview

Interconnection Device, ROHS COMPLIANT

6QDP-016-03.8-TBR-TBL-3-S Parametric

Parameter NameAttribute value
Is it lead-free?Lead free
Is it Rohs certified?conform to
MakerSAMTEC
package instructionROHS COMPLIANT
Reach Compliance Codecompliant
Connector typeINTERCONNECTION DEVICE
Base Number Matches1
F-209 SUPPLEMENT
6QDP–032–06.0–STR–TTR–2
6QDPS–016–06.0–STR–TEU–3–B
0,635
mm
TWINAX CABLES
SPECIFICATIONS
For complete specifications see
www.samtec.com?6QDPS or
www.samtec.com?6QDP
Cable:
30 AWG
Eye Speed™ MS
twinax micro ribbon
(6QDPS)
Signal Routing:
100Ω Differential
Cable Bending Radius:
(11,11mm) 7/16" min
Plating:
Au over 50µ" (1,27µm) Ni
Current Rating:
1 A max
Propagation Delay:
4.67 nsec/meter
Operating Temp Range:
-20°C to +90°C
Skew (pair-to-pair):
<10 ps/ft
Skew (within a pair):
<5 ps/ft
EMI Performance:
FCC Class A
RoHS Compliant:
Yes
6QDPS, 6QDP
SERIES
Increased
Insertion Depth
Mates with:
QMSS-DP, QFSS-DP,
QMS-DP, QFS-DP
APPLICATIONS
Optional
Shielding
30 AWG
Eye Speed ™ MS
twinax ribbon cable
Cable
Length
6" (152,4mm)
12" (304,8mm)
19.68" (0,5m)
39.37" (1m)
Rated @ -3dB Insertion Loss
6QDPS
4.0 GHz / 8.0 Gbps
3.72 GHz / 7.44 Gbps
1.38 GHz / 2.76 Gbps
1.04 GHz / 2.08 Gbps
Differential
Pair routing
APPLICATIONS
(12,70)
.500
TYPE
NO. OF
PAIRS
WIRE
LENGTH
END
NO. 1
END
NO. 2
WIRING
OPTION
SCREW
OPTION
(24,13)
.950
(15,11)
.595
–“XX.X”
6QDPS
= Shielded mates
with QMSS-DP/
QFSS-DP
Processing conditions will
affect mated height.
END TO END
Surface Mount to
Surface Mount
Surface Mount to
Edge Mount (Terminal)
Surface Mount to
Edge Mount (Socket)
Edge Mount (Terminal) to
Edge Mount (Terminal)
Edge Mount (Terminal) to
Edge Mount (Socket)
Edge Mount (Socket) to
Edge Mount (Socket)
L
(23,88)
.940
(21,08)
.830
(20,35)
.801
(18,29)
.720
(17,55)
.691
(16,81)
.662
6QDP
= Unshielded
mates with
QMS-DP/QFS-DP
–016,
–032,
–048,
–064
= Wire Length
in Inches
(95,3mm) 03.8"
minimum
Specify
END
ASSEMBLIES
from chart
–1
= Pin 1 to
Pin 1
Leave
blank for
no Screw
Option
–2
= Pin 1 to
Pin 2
–F
= End No. 1
SURFACE MOUNT
ASSEMBLY
END 1
064
001
END 2
064
001
–3
= Pin 1 to
Second
Last Pin
–S
= End No. 2
OAL = Wire Length +
L
Wire Length
±(1,27) .050
Note:
Cable lengths longer than
40.00" (1 meter) are not
supported with S.I. test data.
Note:
Verify part number and correct
wiring scheme with Samtec’s
Interactive Cable Builder at
www.samtec.com/cable_
builder/pitch.asp
Note:
This Series is non-standard,
non-returnable.
–TTR
=Terminal,
Top,
Notch
Right
–TTL
=
Terminal,
Top,
Notch
Left
–TBR
=
Terminal,
Bottom,
Notch
Right
–TBL
=
Terminal,
Bottom,
Notch
Left
–STR
=
Socket,
001
Top,
Notch
Right,
–STL
=
Socket,
064
Top,
Notch
Left
–SBR
=
Socket,
Bottom,
Notch
Right
001
–SBL
=
Socket,
Bottom,
Notch
Left
064
–B
= Both
Ends
–4
064
001
001
064
064
001
= Pin 1 to
Last Pin
WIRING REQUIREMENTS
WIRING
END OPTIONS
OPTION
1 or 2
TTR, TBL, STL, SBR, TEU to
TTR, TBL, STL, SBR, TED
or
TTL, TBR, STR, SBL, TED to
TTL, TBR, STR, SBL, TEU
TTL, TBR, STR, SBL, TED to
TTR, TBL, STL, SBR, TED
or
TTR, TBL, STL, SBR, TEU to
TTL, TBR, STR, SBL, TEU
001
064
EDGE MOUNT
ASSEMBLY
(7,47)
.294
–TEU
=Terminal,
Edge,
Notch
Up
END 1
064
END 2
3 or 4
001
END NO. 1
(-TTL SHOWN)
END NO. 2
(-STR SHOWN)
–TED
=Terminal,
Edge,
Notch
Down
001
064
WWW.SAMTEC.COM
Show the design plan + Uncle Mario can run better on F4
Previously, I started porting InfoNes to the M4 board in another section, which happened to be used on this board. The board is not back yet, so I have to think about it first (otherwise I will forget...
sjtitr stm32/stm8
Modern urban love
Beijing white-collar workers "looking for love in the same building" have a higher success rate than office romance   Some single white-collar workers in Beijing have started looking for their partner...
6294316 Talking
Why can't I download the program on my LPC?
My lpc546 could be programmed at first, but then it couldn't. The computer could still detect the jlink, but couldn't detect the chip. The power was on....
二狗剩 NXP MCU
Windows CE 6.0 installation sequence
Posted on 2007-05-13 15:59 Walzer1. Install Visual Studio 2005 first. I got the Professional Edition. It is best not to use the default installation, but to customize the components, otherwise it will...
sinpo1984 Embedded System
The necessity of grounding - the inside story of grounding you must know
I reposted this, but I think it's well written. I suggest you read it. Do you know why the unreasonable mobile phone roaming charges are always delayed in being cancelled? Do you know why the one-way ...
clark Industrial Control Electronics
How is the spi0 hardware interrupt of S3C2440 triggered?
In S3c2440_intr.h, the IRQ value of spi0 is 22. I use KernelIoControl to convert the IRQ of spi0 into a logical interrupt value. And associate it with an event, so that as soon as an interrupt occurs,...
为科学执着 Embedded System

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 248  1334  658  677  900  5  27  14  19  13 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号