EEWORLDEEWORLDEEWORLD

Part Number

Search

4303.2614.07

Description
Mains Power Connector, 10A, 250VAC, Male, Quick Connect Terminal
CategoryThe connector    The connector   
File Size122KB,3 Pages
ManufacturerSCHURTER
Websitehttp://www.schurterinc.com/
Environmental Compliance
Download Datasheet Parametric View All

4303.2614.07 Overview

Mains Power Connector, 10A, 250VAC, Male, Quick Connect Terminal

4303.2614.07 Parametric

Parameter NameAttribute value
Is it lead-free?Lead free
Is it Rohs certified?conform to
MakerSCHURTER
Reach Compliance Codecompliant
ECCN codeEAR99
Other featuresSTANDARD: IEC 60320-1/C14, 94V-0
Connector typeMAINS POWER CONNECTOR
Contact to complete cooperationTIN/TIN COPPER
Contact completed and terminatedTIN/TIN COPPER
Contact point genderMALE
Contact materialNOT SPECIFIED
Coupling typeSNAP
DIN complianceNO
IEC complianceYES
JESD-609 codee3/e2
MIL complianceNO
Power Connector Ratings10A, 250VAC
Manufacturer's serial numberKEC
Installation typePANEL
OptionsGENERAL PURPOSE
Shell materialPOLYETHYLENE
Termination typeQUICK CONNECT
Total number of contacts3
Base Number Matches1
POWER ENTRY MODULES /
GERÄTESTECKER-KOMBIELEMENTE
Power entry module Type KEC
– Panel mount: screw-on version, front or rear-side / snap-in
version, front-side
– 3 functions: appliance inlet, fuseholder with
interchangeable fuse drawer for 5 x 20 or 6,3 x 32 mm
fuses, with or without voltage selector (step switch)
– Version with line filter/shield see page 110
KEC
Fuse drawer
Standard or
Medical
Fuse drawer
50
75
100
Socket
Characteristics
• Versions available with or without internal connections
• The fuse drawer “Fingergrip” can be removed by hand
• For added safety “Extra-Safe” fuse drawers are available
Extra-safe fuse drawers satisfy international standards for medical
equipment. The drawer can only be removed with the aid of a tool
• The fuseholder is accessible from the equipment front
• Qualified for use in equipment according to IEC/EN 60950
Technical data
Rated voltage
Rated currents
250 VAC
10 A; VDE, SEV, Semko
13 A; UL
16 A; CSA 1-pole
10 A; CSA 2-pole
> 3 kV between L-N
> 4 kV between L/N-PE
Dielectric strength
(50 Hz, 1 Min.)
Allowable ambient air
temperatures T
a
–25 °C to + 70 ºC
Degree of protection (front side) IP40 acc. to IEC 60529
Protection class
suitable for equipment with prot. cl. l,
acc. to IEC 61140
Terminals
quick-connect 4,8 x 0,8 mm/tin-plated
Panel thickness s
screw-on: max. 8 mm
snap-in: 1,5/2/2,5 mm
Materials: Housing
Thermoplastic, black, UL94 V-0
Appliance-inlet
acc. to IEC/EN 60320-1/C14,
protection class I,
pin-temperature 70 °C
(cold condition)
1- or 2-pole, shocksafe category PC2
acc. to IEC/EN 60127-6, for
fuse-links 5 x 20 or 6,3 x 32 mm
5 x 20: 2,5 W (1-pole)/2 W (2-pole) per p.
6,3 x 32: 3,15 W (1-pole)/2,5 W (2-pole)
per pole
see derating curves. Take note of the
information on page 195
optional,
step switch, 2–4 positions
Fuseholder
Rated power acceptance at
ambient air temp. T
a
23 ºC
Admissible power acceptance
at higher T
a
Voltage selector
www.schurter.com
53
MCU crystal oscillator and voltage
Hello everyone: Is there any relationship between the crystal oscillator added to the microcontroller pin and the voltage? My colleagues in the unit said that under normal circumstances, the maximum f...
bawgijfd Embedded System
Modelsim frequency division program simulation
I am a novice and I need some guidance. The results of the modelsim function simulation and post-simulation are different. What is the reason for this result? ? As shown in the figure, the code is as ...
duanxianzhuang FPGA/CPLD
Teach you to learn Protel2 step by step
Article 2...
lorant PCB Design
How good is Hangshun's chip? Let's see if Huawei 5G uses its chip
Some netizens said that Hangshun chips are not good, they are just slogans and have many problems. Recently I read his official account, which said that Huawei's 5G optical modem uses Hangshun's entry...
蓝猫淘气 Domestic Chip Exchange
Detailed explanation of RS232, RS485, RS485, serial port & handshake
Detailed explanation of RS232, RS485, RS485, serial port & handshake with pictures and texts in the attachment...
jingcheng Linux and Android
Why is it that the FLASH data seen in CCS and the data seen in the HEX file of F2802X are different?
I downloaded the hex file using CODESKIN, but when I looked at the FLASH data through CCS, I found that they were not consistent. There was indeed the same data, but their addresses were different. Wh...
w00d Microcontroller MCU

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 728  1623  87  221  2298  15  33  2  5  47 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号