S114D-5

Description
CENTIGRID SURFACE MOUNT AEROSPACE RELAY DPDT
CategoryMechanical and electronic products    relay   
File Size30KB,3 Pages
ManufacturerTeledyne Technologies Incorporated
Websitehttp://www.teledyne.com/
Download Datasheet Parametric View All

S114D-5 Online Shopping

Suppliers Part Number Price MOQ In stock  
S114D-5 - - View Buy Now

S114D-5 Overview

CENTIGRID SURFACE MOUNT AEROSPACE RELAY DPDT

S114D-5 Parametric

Parameter NameAttribute value
Is it Rohs certified?incompatible
Reach Compliance Codecompli
ECCN codeEAR99
body width8.51 mm
body height9.14 mm
Body length or diameter9.53 mm
Maximum coil current (DC)0.1 A
Coil operating voltage (DC)3.5 V
Coil power450 mW
Coil release voltage (DC)0.14 V
Coil resistance50 Ω
Maximum coil voltage (DC)5.8 V
Nominal coil voltage5 V
Coil/Input Power TypeDC
Contact (AC) maximum rated R load.25A@115VAC
Maximum contact current (AC)0.25 A
Maximum contact current (DC)1 A
Contact (DC) maximum rated R load1A@28VDC
Contact resistance100 mΩ
Maximum contact voltage (AC)115 V
Maximum contact voltage (DC)28 V
Contact/Output Power TypeAC/DC
Electrical life100000 Cycle(s)
Input switching control typeRandom
Insulation resistance10000000000 Ω
Installation featuresSURFACE MOUNT-STRAIGHT
Number of terminals2
operating hours3.5 ms
Maximum operating temperature85 °C
Minimum operating temperature-55 °C
physical size9.53mm x 8.51mm x 6.99mm
Relay actionMOMENTARY
Relay style2 FORM C
Relay functionDPDT
Relay typePOWER/SIGNAL RELAY
release time5.5 ms
sealHERMETICALLY SEALED
surface mountNO
Termination typeSOLDER
weight1.9 g
Base Number Matches1
TELEDYNE RELAYS
CENTIGRID
®
SURFACE MOUNT
AEROSPACE RELAY
DPDT
SERIES
S114
SERIES
DESIGNATION
S114
S114D
S114DD
DPDT basic relay
RELAY TYPE
DPDT relay with internal diode for coil suppression
DPDT relay with internal diodes for coil transient suppression and polarity
reversal protection
INTERNAL CONSTRUCTION
DESCRIPTION
The S114 Series Surface Mount Centigrid
®
Relay is an ultraminiature, hermetically sealed,
armature relay. The low profile height (.360”) and .100” lead spacing make it ideal for
applications where extreme packaging density and/or close PC board spacing are required.
The specially formed leads are pre-tinned to make the relays ideal for most types of surface
mount solder reflow processes.
The basic design and internal construction are identical to the 114 Series Centigrid
®
relays,
and are capable of meeting Teledyne Relays
T
2
R
®
requirements. The following unique
construction features and manufacturing techniques provide overall high reliability and
excellent resistance to environmental extremes:
All welded construction.
Unique uni-frame design providing high magnetic efficiency and mechanical rigidity.
High force/mass ratios for resistance to shock and vibration.
Advanced cleaning techniques provide maximum assurance of internal cleanliness.
Precious metal alloy contact material with gold plating assures excellent high current
and dry circuit switching capabilities.
UNIFRAME
ARMATURE
UPPER
STATIONARY
CONTACT
MOVING
CONTACT
LOWER
STATIONARY
CONTACT
ENVIRONMENTAL AND
PHYSICAL SPECIFICATIONS
Temperature
(Ambient)
Vibration
Shock
Acceleration
Enclosure
Weight
Reflow
Temperature
-65°C to +125°C
30 g’s to 3000 Hz (Note 3)
75 g’s for 6 msec. (Note 3)
half-sine
50 g’s (Note 3)
All welded, hermetically sealed
0.07 oz (1.9 gms.) max.
260°C max. temp.
5 min. max. above 180°C
The S114D and S114DD Series utilize internal discrete silicon diodes for coil suppression
and polarity reversal protection.
By virtue of its inherently low intercontact capacitance and contact circuit losses, the S114
relay has shown itself to be an excellent ultraminiature RF switch for frequency ranges well
into the UHF spectrum. A typical RF application for the S114 relay is in hand held radio
transceivers, wherein the combined features of good RF performance, small size, low coil
power dissipation and high reliability make it a preferred method of transmit-receive
switching (see Figure 1).
56
Some companies have to pay customs duties when applying for samples. What credit card should they use?
Some companies have to pay tariffs when applying for samples, which are calculated in US dollars and must be paid by credit card. I wonder what cards you use? How much does it cost?...
0212009623 Microcontroller MCU
DT-1 Online Liquid Density Meter (Densitometer)
[font=Times New Roman]DT-1[/font][font=宋体]Online liquid density test transmitter can measure the density of various liquids or liquid mixtures online. Therefore, it can be widely used in petrochemical...
zhaohuimiduyi Test/Measurement
[New Year Cool Learning] Question 10: What is the impact of the oscilloscope probe on the circuit?
[font=微软雅黑][b]zca123 asked: Please talk about the influence of the oscilloscope's test leads on the circuit, and the precautions. ×1 and ×10 [/b] [b]dontium replied: [/b]The oscilloscope's test leads ...
soso Analog electronics
Read and write the entire information segment A of the Flash in MSP430F169
Read and write the entire information segment A of the Flash in MSP430F169...
Aguilera Microcontroller MCU
A small question about VCA820
Dear experts, I have tested the diagram according to Figure 84 on page 23 of the VCA820 datasheet. Rf and Rg are 1K and 200 respectively. The gain should be 10 times, but now the maximum is only 2~3 t...
prcwjj Microcontroller MCU
What is the role of GPIO_Speed in the STM32 library
In the STM32 library, each group of I/O ports has a configuration structure GPIO_InitTypeDef. What is the function of the GPIO_Speed member? ? ?...
WKfirst stm32/stm8

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2733  763  2198  2929  1819  56  16  45  59  37 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号