EEWORLDEEWORLDEEWORLD

Part Number

Search

86010C-H-34SN

Description
MIL Series Connector, 34 Contact(s), Metal, Female, Crimp Terminal, Receptacle
CategoryThe connector   
File Size65KB,1 Pages
ManufacturerHiRel Connectors Inc
Websitehttps://hirelco.net
Download Datasheet Parametric View All

86010C-H-34SN Overview

MIL Series Connector, 34 Contact(s), Metal, Female, Crimp Terminal, Receptacle

86010C-H-34SN Parametric

Parameter NameAttribute value
MakerHiRel Connectors Inc
Reach Compliance Codeunknown
Other featuresSTANDARD: MIL-DTL-38999
Back shell typeSOLID
Body/casing typeRECEPTACLE
Connector typeMIL SERIES CONNECTOR
Contact to complete cooperationNOT SPECIFIED
Contact point genderFEMALE
Coupling typeTHREADED
DIN complianceNO
empty shellNO
Environmental characteristicsCORROSION RESISTANT; ENVIRONMENT RESISTANT; FLUID RESISTANT
Filter functionNO
IEC complianceNO
MIL complianceYES
Manufacturer's serial number86010
Plug informationMULTIPLE MATING PARTS AVAILABLE
Mixed contactsNO
Installation typeCABLE AND PANEL
OptionsGENERAL PURPOSE
Shell materialMETAL
Housing sizeH
Termination typeCRIMP
Total number of contacts34
Base Number Matches1
D38999/24
Jam Nut Mount Environment Resistant Receptacle
MIL-DTL-38999
Series III – Threaded Coupling
NOTES:
1. PANEL THICKNESS .126/.050 [3.20/1.58]
2. CONNECTOR CONTAINS REQUIRED FEATURES FOR
PROPER FIT IN A TYPE "E" PANEL
3. FOR CONNECTOR COMPONENTS AND ACCESSOROES,
SEE PAGE C-5
ØA
2 PLCS
1.279 [32.5]
MAX
.889 [22.6] MAX.
.519/.500 [13.2/12.7]
(FULLY MATED INDICATOR
BAND - RED)
S
P
SEE CONTACT
STYLE
DESIGNATOR
ON ORDERING
INFORMATION
PAGE
B Flat
BB Thd
G Thd
O-Ring
W
VV Thd
SHELL SHELL
SIZE
SIZE CODE
9
11
13
15
17
19
21
23
25
A
B
C
D
E
F
G
H
J
ØA
±.011
[±0.3]
1.189 [30.2]
1.374 [34.9]
1.500 [38.1]
B Flat BB Thd G Thd
CLASS 2A
+.004/-.006
[+0.10/-0.15] 0.1P-0.3L-TS
.651 [16.53]
.751 [19.07]
.938 [23.82]
.6250
.7500
.8750
1.0000
1.1875
1.2500
1.3750
1.5000
1.6250
M17 x 1.0
M20 x 1.0
M25 x 1.0
M28 x 1.0
*M32 x 1.0
M35 x 1.0
M38 x 1.0
M41 x 1.0
M44 x 1.0
P
S
±.016
[±0.4]
VV Thd
-6g 0.100R
M12 x 1.0
M15 x 1.0
M18 x 1.0
M22 x 1.0
M25 x 1.0
M28 x 1.0
M31 x 1.0
M34 x 1.0
M37 x 1.0
W
+.035/-.004
[+0.9/-0.1]
.087 [2.2]
.087 [2.2]
.087 [2.2]
.087 [2.2]
.087 [2.2]
.118 [3.0]
.118 [3.0]
.118 [3.0]
.118 [3.0]
-6g 0.100R +.024/-.000
[+0.6/-0.0]
.555 [14.1] 1.063 [27.0]
.555 [14.1] 1.252 [31.8]
.555 [14.1] 1.374 [34.9]
.555 [14.1] 1.500 [38.1]
.555 [14.1] 1.626 [41.3]
.555 [14.1] 1.811 [46.0]
.555 [14.1] 1.937 [49.2]
.555 [14.1] 2.063 [52.4]
.555 [14.1] 2.189 [55.6]
1.626 [41.3] 1.062 [26.97]
1.752 [44.5] 1.187 [30.15]
1.937 [49.2] 1.312 [33.32]
2.063 [52.4] 1.437 [36.50]
2.189 [55.6] 1.562 [39.67]
2.311 [58.7] 1.687 [42.85]
* = MODIFIED MAJOR DIA. 1.258/1.252 [31.95/31.80]
DIMENSIONS ARE IN INCHES [MILLIMETERS]
United States
– 760 W. Wharton Drive, Claremont CA. 91711
Ph: 909-626-1820
FAX: 909-399-0626
Web:
www.HIRELCO.com
Europe
– 5 Rue Des Longues Raies, Z.I. Des Garennes, 78440; Gargenville, France
Ph: 33(0) 1-309-38999 or U.K. 44(0)1-980-843887
FAX 33(0) 1-309-38913
Web:
www.HIRELCO.com
C-16
Conflict between watchdog and sleep mode of STM32 chip
Dear experts: I am going to make a handheld device recently and need to use the STOP mode of stm32F103. But at the same time, I have enabled the independent watchdog. Whenever I enter the STOP mode, t...
孤帆 stm32/stm8
MCD2/ICD2 Beginner's Guide
[i=s]This post was last edited by paulhyde on 2014-9-15 09:37[/i]...
gina Electronics Design Contest
Talk about the upper and lower tubes of the buck circuit_DC-DC BUCK bootstrap circuit
What is a bootstrap capacitor? The DC-DC BUCK chip has a pin called BOOT, some called BST, as shown below:How does the bootstrap capacitor work? The following is the block diagram of the DCDCBUCK chip...
Jacktang Analogue and Mixed Signal
I feel that the RAM of msp430 is not enough
Less than 2K RAM, if there is more data (due to the requirement of speed, it cannot be placed in Flash), excluding the local variables called by the subroutine, I don't know how much can be used. The ...
news986 Microcontroller MCU
Can intelligent robots recognize themselves?
Today's robots can only be considered intelligent, they will work automatically according to instructions. But can they achieve autonomous work like humans, with plans and purposes, and know why they ...
ginny Robotics Development
ETA Intelligent Power Relay E-1048-8D for Automotive Electronics
On March 6, ETA launched the E-1048-8D (E-1048 Dice), an intelligent power relay for the transportation industry, which can remotely disconnect electronic loads and match the 4-pin automotive electron...
frozenviolet Automotive Electronics

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 250  1196  2393  972  112  6  25  49  20  3 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号