Part Number

Search

6QDPS-064-12.0-STL-TED-2-F

Description
Interconnection Device, ROHS COMPLIANT
CategoryThe connector   
File Size655KB,1 Pages
ManufacturerSAMTEC
Websitehttp://www.samtec.com/
Environmental Compliance  
Download Datasheet Parametric View All

6QDPS-064-12.0-STL-TED-2-F Overview

Interconnection Device, ROHS COMPLIANT

6QDPS-064-12.0-STL-TED-2-F Parametric

Parameter NameAttribute value
Is it lead-free?Lead free
Is it Rohs certified?conform to
MakerSAMTEC
package instructionROHS COMPLIANT
Reach Compliance Codecompliant
Is SamacsysN
Connector typeINTERCONNECTION DEVICE
Base Number Matches1
F-209 SUPPLEMENT
6QDP–032–06.0–STR–TTR–2
6QDPS–016–06.0–STR–TEU–3–B
0,635
mm
TWINAX CABLES
SPECIFICATIONS
For complete specifications see
www.samtec.com?6QDPS or
www.samtec.com?6QDP
Cable:
30 AWG
Eye Speed™ MS
twinax micro ribbon
(6QDPS)
Signal Routing:
100Ω Differential
Cable Bending Radius:
(11,11mm) 7/16" min
Plating:
Au over 50µ" (1,27µm) Ni
Current Rating:
1 A max
Propagation Delay:
4.67 nsec/meter
Operating Temp Range:
-20°C to +90°C
Skew (pair-to-pair):
<10 ps/ft
Skew (within a pair):
<5 ps/ft
EMI Performance:
FCC Class A
RoHS Compliant:
Yes
6QDPS, 6QDP
SERIES
Increased
Insertion Depth
Mates with:
QMSS-DP, QFSS-DP,
QMS-DP, QFS-DP
APPLICATIONS
Optional
Shielding
30 AWG
Eye Speed ™ MS
twinax ribbon cable
Cable
Length
6" (152,4mm)
12" (304,8mm)
19.68" (0,5m)
39.37" (1m)
Rated @ -3dB Insertion Loss
6QDPS
4.0 GHz / 8.0 Gbps
3.72 GHz / 7.44 Gbps
1.38 GHz / 2.76 Gbps
1.04 GHz / 2.08 Gbps
Differential
Pair routing
APPLICATIONS
(12,70)
.500
TYPE
NO. OF
PAIRS
WIRE
LENGTH
END
NO. 1
END
NO. 2
WIRING
OPTION
SCREW
OPTION
(24,13)
.950
(15,11)
.595
–“XX.X”
6QDPS
= Shielded mates
with QMSS-DP/
QFSS-DP
Processing conditions will
affect mated height.
END TO END
Surface Mount to
Surface Mount
Surface Mount to
Edge Mount (Terminal)
Surface Mount to
Edge Mount (Socket)
Edge Mount (Terminal) to
Edge Mount (Terminal)
Edge Mount (Terminal) to
Edge Mount (Socket)
Edge Mount (Socket) to
Edge Mount (Socket)
L
(23,88)
.940
(21,08)
.830
(20,35)
.801
(18,29)
.720
(17,55)
.691
(16,81)
.662
6QDP
= Unshielded
mates with
QMS-DP/QFS-DP
–016,
–032,
–048,
–064
= Wire Length
in Inches
(95,3mm) 03.8"
minimum
Specify
END
ASSEMBLIES
from chart
–1
= Pin 1 to
Pin 1
Leave
blank for
no Screw
Option
–2
= Pin 1 to
Pin 2
–F
= End No. 1
SURFACE MOUNT
ASSEMBLY
END 1
064
001
END 2
064
001
–3
= Pin 1 to
Second
Last Pin
–S
= End No. 2
OAL = Wire Length +
L
Wire Length
±(1,27) .050
Note:
Cable lengths longer than
40.00" (1 meter) are not
supported with S.I. test data.
Note:
Verify part number and correct
wiring scheme with Samtec’s
Interactive Cable Builder at
www.samtec.com/cable_
builder/pitch.asp
Note:
This Series is non-standard,
non-returnable.
–TTR
=Terminal,
Top,
Notch
Right
–TTL
=
Terminal,
Top,
Notch
Left
–TBR
=
Terminal,
Bottom,
Notch
Right
–TBL
=
Terminal,
Bottom,
Notch
Left
–STR
=
Socket,
001
Top,
Notch
Right,
–STL
=
Socket,
064
Top,
Notch
Left
–SBR
=
Socket,
Bottom,
Notch
Right
001
–SBL
=
Socket,
Bottom,
Notch
Left
064
–B
= Both
Ends
–4
064
001
001
064
064
001
= Pin 1 to
Last Pin
WIRING REQUIREMENTS
WIRING
END OPTIONS
OPTION
1 or 2
TTR, TBL, STL, SBR, TEU to
TTR, TBL, STL, SBR, TED
or
TTL, TBR, STR, SBL, TED to
TTL, TBR, STR, SBL, TEU
TTL, TBR, STR, SBL, TED to
TTR, TBL, STL, SBR, TED
or
TTR, TBL, STL, SBR, TEU to
TTL, TBR, STR, SBL, TEU
001
064
EDGE MOUNT
ASSEMBLY
(7,47)
.294
–TEU
=Terminal,
Edge,
Notch
Up
END 1
064
END 2
3 or 4
001
END NO. 1
(-TTL SHOWN)
END NO. 2
(-STR SHOWN)
–TED
=Terminal,
Edge,
Notch
Down
001
064
WWW.SAMTEC.COM
Advanced package stacking technology
The industry expects IC package developers to integrate more functions and higher performance with each product upgrade. The trend of shrinking product size, increasing performance requirements and hi...
oych1017 Embedded System
Correct use of thermocouples
[table=98%][tr][td][font=Verdana] For example, the installation position and insertion depth of the thermocouple cannot reflect the actual temperature of the furnace. In other words, the thermocouple ...
锐特0087 Industrial Control Electronics
About compiling errors in DSP Builder
My software version is MATLAB 2010b + DSP 11.0 + QUATUS 11.0 (all 32-bit). Now that the crack is complete, when I click compile, I get an error message: Info: Generating HDL Info: Analyzing Simulink m...
yifeifei000 FPGA/CPLD
How to load WINCE serialusbfn.dll
When testing the synchronization between WINCE and PC, it was found that serialusbfn.dll was not loaded. The corresponding components and registry entries have been added. I don’t know if there is any...
woolsack Embedded System
Help, I have encountered a big problem. In the single scan mode of R5F100LE ADC, the data sampled by the four channels is shifted downward
[size=14px]When reading data, the first sampling reading changed to the second digit, the second data became the third digit, the third data became the fourth digit, and the fourth data became the fir...
牵着泰迪去打猎 Renesas Electronics MCUs
RS485 reception has problems and data cannot be received
I am debugging RS485. The transmission is OK, but the reception is not receiving any data. I have enabled the reception. I use the RS232RS485 adapter, one end connects to the PC, the other end connect...
fanyang1968 Embedded System

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 267  2662  2797  1680  1987  6  54  57  34  41 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号