EEWORLDEEWORLDEEWORLD

Part Number

Search

7711-0404BA

Description
1 FUNCTIONS, 100 V, 5 A, DATA LINE FILTER
Categoryfilter   
File Size134KB,6 Pages
ManufacturerTusonix
Websitehttp://www.tusonix.com
Download Datasheet Parametric View All

7711-0404BA Overview

1 FUNCTIONS, 100 V, 5 A, DATA LINE FILTER

7711-0404BA Parametric

Parameter NameAttribute value
Is it lead-free?Contains lead
Is it Rohs certified?incompatible
MakerTusonix
Reach Compliance Codecompliant
Is SamacsysN
Other featuresC-TYPE CIRCUIT
capacitance100 µF
filter typeDATA LINE FILTER
high15.8 mm
Maximum insertion loss19 dB
Minimum insulation resistance10000 MΩ
JESD-609 codee3
length46.66 mm
Manufacturer's serial number77
Installation typePANEL MOUNT
Number of functions1
physical sizeL46.66XB8.0XH15.8 (mm)/L1.837XB.315XH.622 (inch)
Rated current5 A
Rated voltage100 V
Terminal surfaceMATTE TIN
width8 mm
Base Number Matches1
Revision 3, updated December 18, 2000
7741 North Business Park Drive
Tucson, Arizona 85743
Ph: 520-744-0400 Fax: 520-744-6155
Website: www.tusonix.com
E-mail: sales@tusonix.com
The TUSONIX 77, 78 and 79 Series Filtered
Assembly Plates provide ease of installation and
line customization of standard size plates. Filter
Plates are an efficient and cost effective solution
for filtering multiple lines into, or between, different
system compartments. For higher frequency appli-
cations (above 50 MHz) filter plates can be more
effective than typical surface mount solutions. The
inherent shielding characteristic of the plates cre-
ates an effective RF barrier offering excellent inser-
tion loss and isolation for frequencies above 5 MHz.
The preassembled plates are 100% tested for criti-
cal parameters and greatly reduce the time and re-
sources that are required to individually install sol-
der mount filters.
The 77 Series Quick Connect and 78 Series
Miniature Quick Connect Filter Plates (see pages
2-3) feature a base plate with built in installation
clips. These clips allow for cost effective mounting
into the system bulkhead without the expense or
time associated with traditional hardware.
The Quick Connect Filter Plate offers one or
two rows totalling up to 26 lines. The Miniature
Quick Connect Filter Plate provides a lower profile
and up to 10 lines. Up to 40 lines are available on
the standard bolt-in filter plate in the two row con-
figuration.
77, 78 and 79 Series Filter Plate Mechanical
Specifications:
Base Plate Material ......
Copper Alloy or
Nickel-Silver
Base Plate Thickness
77 and 78 Series .....
0.012" [0.3mm]
79 Series .................
0.028" [0.7mm]
Plating ...........................
Matte Tin
Lead Material ................
Copper Alloy
Lead Plating ..................
Gold Plate
Lead Diameter ..............
Ø 0.025" [0.64mm]
Current Rating ..............
5 Amps
For ordering information see page 5.
1
Tips for testing the phase and amplitude time curve of mobile phone amplifiers
Reuse of amplifier designs is a common method used by mobile communication designers to minimize manufacturing bill of materials costs when developing new networks. For example, the same power amplifi...
JasonYoo Test/Measurement
LM3S JTAG is locked and solved
I had some free time in the evening, so I planned to continue my LM3S journey. However, I failed to download the code on KEIL. I was wondering if the system had broken down after I installed QQ Live t...
leang521 Microcontroller MCU
LM3S811DDLLXXRR Notes 3: Clock and PLL
Basic Clock Sources The device has two clock sources available: ■ Internal Oscillator (IOSC): The internal oscillator is an on-chip clock source. It does not require any external components. The frequ...
ddllxxrr Microcontroller MCU
How do the IC card 45db041 chip correspond to the 8 pins on the card holder?
As the title says, there is no pin corresponding to the IC card module in the datasheet. No information is found on the Internet....
lordice Embedded System
Xiang version, is there any difference between TIM2 of RBT6 and TIM2 of RET6?
The initialization and interrupt code that works perfectly on RBT6 cannot cause TIM2 interrupts when used on RET6. Is there a difference in TIM2 between medium-density and high-density devices?...
emaster stm32/stm8
The impact of operational amplifier input offset voltage on input signal
I recently made a uV DC weak signal amplifier circuit. The input signal is smaller than the offset voltage of the op amp. The amplification factor is 100, but the result from the op amp is not what I ...
lclhitwh Analog electronics

Technical ResourceMore

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1643  1898  2413  2632  631  34  39  49  53  13 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号