Packard Electric Metri-Pack 150 Series, M12 - 4 Pole *
G1/4A DIN 3852-E, G1/4A DIN 3852-A *
304 Stainless Steel (1.4301)
4 - 20 mA, 0.5 - 4.5 VDC, 0 - 5 VDC, 0 - 10 VDC
Attributes
Hermetically Sealed
Rugged & Durable
Compact & Light-weight
Resistant to Chemical Attack
Superior Long-Term Stability & Repeatability
Outstanding Shock & Vibration Performance
Typical Applications
Compressors
Hydraulic Systems
Agricultural Equipment
Construction Equipment
Heat Pumps
Wind Energy
HVAC Systems
Chemical Industry
Description
The PTE5000 utilizes Kavlico’s thin film strain gauge sensing technology, incorporating an hermetically
sealed design with no internal sealing required. Designed for harsh environments, a rugged 304 stainless
steel housing surrounds the PTE5000 transducer.
The PTE5000’s small, compact design as well as its low overall weight makes it ideal
for applications with spacing and weight limitations. This easy-to-use sensor is media
resistant, which allows it to be used for a broad range of liquid and gaseous media. It
can be used at high operating temperatures and has internal temperature compensation.
Highly reliable, the PTE5000 provides accurate, high pressure measurements every time.
www.kavlico.com
Technical Specifications
Pressure Ranges
from 0 to …
Proof pressure
Burst pressure
bar (gage)
bar (gage)
bar (gage)
6
12
60
10
20
100
16
32
160
25
50
200
40
80
320
60
120
480
100
200
600
160
320
960
250
500
1000
400
800
1600
600
1200
2400
Physical
Operating Life Cycle
Vibration Resistance
Shock Resistance
Drop Test
Weight
Ingress Protection
Medium Temperature
Storage Temperature
Media
*4
min. 10 million full pressure cycles over the full range
IEC 60068-2-64 (RANDOM) 20 PSD
25 g minimum according to DIN EN 60068-2-27
1 meter drop on concrete as per SAE J1455 / DIN EN 60068-2-3-1
≤
50 grams (without mating connector)
IP 65 or IP67 - depending on electrical connector
-30°C to + 120°C (others on request)
-30°C to + 100°C (dep. on electrical connector & external seal ring capability)
*4
All class II fluids and gases compatible with stainless steel 304 (1.4301)
Environmental Temperature
-30°C to + 100°C (dep. on electrical connector & external seal ring capability)
*4
For more details see How to Order
Performance
Accuracy
*1
Non-linearity
*2
Non-repeatability
1-year stability
Temp. Coefficients - Zero
Temp. Coefficients - Span
*1
*2
≤
0.5 % of span
*3
0.2 % of span
*3
0.1 % of span
*3
0.2 % of span
*3
0.2 % of span / 10 K within temperature range 0°C to + 80°C.2 %
0.2 % of span / 10 K within temperature range 0°C to + 80°C.2 %
Including non-linearity, hysteresis, non-repeatability, zero point and full scale error (corresponds to error of measurement per IEC 61298-2). Adjusted in vertical mounting position with pressure port down.
BFSL according to IEC 61298-2 reference conditions to EN 61298-1
Others on request
*3
www.kavlico.com
Data Sheet PTE5000
2
Electrical
0.5…4.5 VDC
ratiometric
5 VDC ± 5%
≤
25 mW
min. 6 VDC
Yes
*5
500 VDC
Yes
*6
Output Signal
Operating Supply Signal
Power Consumption
Overvoltage Protection
Short-circuit Proofness
Insulation Voltage
Load
Response Time
*5
4…20 mA
8-30 VDC
≤
600 mW
min. 33 VDC
not applicable
500 VDC
0…5 VDC
8-30 VDC
≤
600 mW
min. 33 VDC
Yes
*5
500 VDC
Yes
*6
≥
4.7 kΩ
0…10 VDC
14-30 VDC
≤
600 mW
min. 33 VDC
Yes
*5
500 VDC
Yes
*6
≥
4.7 kΩ
Reverse Polarity Protection
Yes
*6
≤
(Vsup-8 VDC)/(0.02 A) [Ω]
≥
4.7 kΩ
≤
5 ms max. to 63% of full scale pressure with step change on input
for min. 3 intervals at 5 minutes each
for min. 10 seconds on assigned pins
*6
Approvals & Certificates
Pressure equipment directive 97/23/EC
EMC directive 2004/108/EEC, EN 61 326 Emission (Group 1, Class B)
and Immunity (industrial locations), EMI, ESD protected
Standard(s) for Safety: Electrical Equipment for Measurement, Control and
Laboratory Use - UL 61010-1
2011/65/EU ROHS Directive
CE Compliance
UL
ROHS
www.kavlico.com
Data Sheet PTE5000
3
Dimensions
Pressure Sensor with Electrical Connection
Dimensions in mm [Inch]
M12 Pin Call Outs
Output
4-20 mA
0.5-4.5 VDC ratiometric
0-5 VDC
0-10 VDC
Pin 1
Vsup
Vsup
Vsup
Vsup
Pin 2
...
...
...
...
Pin 3
lout
Vout
Vout
Vout
Pin 4
...
GND
GND
GND
18 mm Pin Call Outs
Output
4-20 mA
0.5-4.5 VDC ratiometric
0-5 VDC
0-10 VDC
Pin 1
Vsup
Vsup
Vsup
Vsup
Pin 2
lout
Vout
Vout
Vout
Pin 3
...
GND
GND
GND
Pin 4
...
...
...
...
Packard (metri-pack 150) Pin Call Outs
Output
4-20 mA
0.5-4.5 VDC ratiometric
0-5 VDC
0-10 VDC
Pin 1
lout
GND
GND
GND
Pin 2
Vsup
Vsup
Vsup
Vsup
Pin 3
...
Vout
Vout
Vout
9.4 mm Pin Call Outs
Output
4-20 mA
0.5-4.5 VDC ratiometric
0-5 VDC
0-10 VDC
Pin 1
Vsup
Vsup
Vsup
Vsup
Pin 2
lout
Vout
Vout
Vout
Pin 3
...
GND
GND
GND
Pin 4
...
...
...
...
www.kavlico.com
Data Sheet PTE5000
4
Pressure Connections and Recommended Installation Torque
I learned about the ADC of stm32, but why is the result high (displaying 4095) when the pin is not input? #define ADC1_DR_Address ((u32)0x4001244C) vu16 ADC1ConvertedValue[2]; void DMA1_Config(void)//...
When I erase the Nor flash, after the final erase or word programming operation is completed, the verification function is as follows: bool SST39VF320X::Check_Toggle_Ready (U32 Dst, U32 MaxCycles) { U...
I want to ask you guys, is IAR case sensitive when writing programs? For example, if I write the entire main program in lowercase letters, but use lowercase letters in some subroutines, and the same v...
In early 2002, I started to write a working program for an IC card prepaid electricity meter. The meter used Philips' 8-bit 51-expanded single-chip microcomputer
87LPC764
, and wa...[Details]
To differentiate their products in a crowded and competitive market, manufacturers of handheld devices often consider battery life and power management as key selling points for cell phones, PDAs, ...[Details]
July 11, 2012, Beijing - Altera Corporation (NASDAQ: ALTR) today announced the launch of 40-Gbps Ethernet (40GbE) and 100-Gbps Ethernet (100GbE) intellectual property (IP) core products. These core...[Details]
1 Introduction
As an emerging microfabrication technology, micro-electromechanical system (MEMS) technology has begun to be applied in various fields. It can integrate functions such as inform...[Details]
1. System Structure
This system is a simulation system of indoor air-conditioning temperature/humidity control system. The data acquisition and control center collects temperature/humidity...[Details]
1 Introduction
PROFIBUS is an international, open, and manufacturer-independent fieldbus standard. It is widely used in manufacturing automation, process industry automation, and automatio...[Details]
1 Introduction
Building Automation System (BAS) is a distributed monitoring system (DCS) designed according to distributed information and control theory. It is the result of the mutual de...[Details]
Since the No. 4 blast furnace of Handan Iron and Steel was put into operation in 1993, its external equipment has been seriously aged, and the original PLC control system TDC3000 of the hot blast furn...[Details]
1 Introduction
With the development of control, computer, communication, network technology, etc., a new control technology, namely fieldbus, has emerged in the field of industrial control...[Details]
With the rapid development of intelligent control technology, computers and information technology, the trend of information appliances IA (Information Application), computers and communications integ...[Details]
Flooded Batteries
This battery developed in Germany can be used to power flashlights, strobe lights and toys as long as it is filled with water. This battery can be stored for 50 years and can...[Details]
In the single-chip microcomputer system, in addition to display devices, sound devices are often used, and the most common sound device is the buzzer. Buzzers are generally used for some low-demand...[Details]
Introduction
Liquid crystal, as a display device, is widely used in low-power products such as instruments, meters, and electronic equipment with its unique advantages. In the past, the displ...[Details]
Among the many members of the single-chip microcomputer family, the MCS-51 series of single-chip microcomputers has occupied the main market of industrial measurement and control and automation eng...[Details]