100 psis to 299 psis (-40°C to 85°C [-40°F to 185°F])
100 psis to 299 psis (>85°C to 125°C [>185°F to 257°F])
>300 psis (-40°C to 125°C [-40°F to 257°F])
with
L, M, P
electrical connector types:
100 psis to 299 psis (-40°C to 65°C [-40°F to 149°F])
100 psis to 299 psis (>65°C to 125°C [>149°F to 257°F])
>300 psis (-40°C to 65°C [-40°F to 149°F])
>300 psis (>65°C to 125°C [>149°F to 257°F])
1
Parameter
<2 ms
±0.25 %FSS
±0.50 %FSS
±3 %FSS
±2 %FSS
±3 %FSS
±10 %FSS
±2 %FSS
±10 %FSS
±15 %FSS
±5 %FSS
±15 %FSS
Includes pressure non-linearity (BFSL), pressure hysteresis and pressure non-repeatability. Thermal errors are not included. (See
Figure 1.)
2
Includes offset error, full scale span error, pressure non-linearity (BFSL), pressure hysteresis, pressure non-repeatability, thermal
effect on offset, thermal effect on span, and thermal hysteresis. (See Figure 1.)
Sensing and Internet of Things
3
Heavy Duty Pressure Transducers
MLH Series, 6 bar to 550 bar | 50 psi to 8000 psi
Figure 2. Regulated Output Operating and Temperature Compensation
125
124
123
122
121
120
119
118
117
116
Operating Temperature (°C)
Operating and temperature
compensated area
for regulated output
6
8
10
12
14
16
18
20
22
24
26
28
30
Supply Voltage (Vdc)
Note: The dot indicates the maximum operating temperature of 125°C [257°F] with a 24 V supply.
Figure 3. Current Output Operating and Temperature Compensation
125
120
115
110
105
100
95
90
85
80
75
70
65
60
10 Ohm
load
250 Ohm
load
Operating Temperature (°C)
Operating and temperature
compensated area
for current output
6
8
10
12
14
16
18
20
22
24
26
28
30
Supply Voltage (Vdc)
Note: The operating area is extended with a 250 Ohm resistor. Higher loads extend the operating area. The dot indicates the
maximum operating temperature when using a 24 V supply and a 250 Ohm resistor.
CAUTION
PRODUCT DAMAGE DUE TO MECHANICAL ISSUES
• Ensure torque specifications are determined for the specific application. Values provided are for reference only. (Mating
materials and thread sealants can result in significantly different torque values from one application to the next.)
• When using mating parts made of stainless steel, use a thread sealant with anti-seize properties to prevent thread galling.
Ensure the sealant is rated for the application.
• Use appropriate tools (such as an open ended wrench or deep well socket) to install transducers.
• Always hand-start transducers into the hole to prevent cross threading and damage.
• Ensure that torque is not applied to the electrical connector.
• Ensure that the proper mating electrical connector with a seal is used to connect the transducer. Improper or damaged
seals can compromise ingress protection, leading to short circuits.
Failure to comply with these instructions may result in product damage.
CAUTION
PRODUCT DAMAGE DUE TO PARTICULATES
• Ensure that a filter is used upstream of the transducer to keep media flow free of larger particulates and increased humidity.
All MLH Series transducers are dead-ended devices; particulate accumulation and condensing moisture may affect
transducer output.
• It is recommend that the transducer be positioned with the port facing downwards; any particulates in the system are less
likely to enter and settle within the pressure transducer if it is in this position.
• Ensure that the media does not create a residue when dried. Build-up inside the transducer may affect transducer output;
rinsing of a dead-ended transducer is potentially difficult and has limited effectiveness in removing residue.
Failure to comply with these instructions may result in product damage.
Sensing and Internet of Things
4
Heavy Duty Pressure Transducers
Figure 4. Nomenclature and Order GuideE
MLH Series, 6 bar to 550 bar | 50 psi to 8000 psi
For example, MLH150PSB01B defines an MLH Series Heavy Duty Pressure Transducer, 150 psi pressure range, sealed
gage pressure reference, Metri-Pack 150 electrical connector type, 1/4-18 NPT pressure port type, 4 mA to 20 mA output.
MLH
Series
Heavy
Duty
Pressure
Transducer
1
150
P
S
B
01
B
Output Transfer Function
A
B
C
D
E
G
Ratiometric: 0.5 Vdc to 4.5 Vdc
from 5 Vdc excitation
Current: 4 mA to 20 mA
Regulated: 1 Vdc to 6 Vdc
Regulated: 0.25 Vdc to 10.25 Vdc
Regulated: 0.5 Vdc to 4.5 Vdc
Regulated: 1 Vdc to 5 Vdc
MLH
Pressure Range
bar
psi
50
100
150
200
250
300
500
1000
2000
3000
5000
8000
Hirschmann
Cable harness,
3 meter cable
length
33
006
010
016
025
040
060
100
160
250
350
500
550
Unit
B
P
bar
psi
6
10
16
25
40
60
100
160
250
350
500
550
050
100
150
200
250
300
500
01K
02K
03K
05K
08K
Electrical Connector Type
Metri-Pack 150
3
Cable harness,
1 meter cable
length
3
Pressure Port Type
01
1/4-18 NPT
(ANSI B1.20.1)
B
L
54
M10x1 with O-ring seal
(ISO 6149-2)
5
06
1/8-27 NPT
(ANSI B1.20.1)
55
M12x1.5 with O-ring seal
(ISO 6149-2)
5
C
M
09
7/16-20 UNF
1/4 in 45º
Flare Female
Schrader with
depressor
1/2-14 NPT
(ANSI B1.20.1)
56
M14x1.5 with O-ring seal
(ISO 6149-2)
5
M12x1
(Brad Harrison micro)
Flying leads
11
57
M16x1.5 with O-ring seal
(ISO 6149-2)
5
Pressure Reference
G
Vented gage (relative)
S
Sealed gage
2
D
P
DIN 43650-C, 8 mm male
13
R 1/4-19 BSPT
(ISO 7-1)
58
M18x1.5 with O-ring seal
(ISO 6149-2)
5
19
R 1/8-28 BSPT
(ISO 7-1)
59
M20x1.5 with O-ring seal
(ISO 6149-2)
5
Metri-Pack 150 mating connector
3
G
50
Deutsch DTM04-3P
(integral)
3/8-24 UNF with O-ring seal
(SAE J1926-2)
5
60
G1/8-28 BSPP
with bonded washer
(DIN 3852-2)
5, 6
G1/4-19 BSPP
with bonded washer
(DIN 3852-2)
5, 6
G1/8-28 BSPP
with elastomeric seal
(ISO 1179-2)
5
G1/4-19 BSPP
with elastomeric seal
(ISO 1179-2)
5
51
AMP Superseal 1.5
4
7/16-20 UNF with O-ring seal
(SAE J1926-2)
5
61
T
H
52
1/2-20 UNF with O-ring seal
(SAE J1926-2)
5
62
53
1
2
9/16-18 UNF with O-ring seal
(SAE J1926-2)
5
63
Not all catalog listing combinations are available. Custom products are available. Please contact Honeywell.
Sealed gage option is only available in pressure ranges at or above 8 bar | 100 psi.
3
Metri-Pack 150 mating connectors with shielded cable and 22 AWG wire are available from Honeywell. Order part no. 3685301 for 1 m [3.2 ft] cable length and part no. 3685302 for 3 m
[9.8 ft] cable length.
4
Available with Output Transfer Function
A
only.
5
Seal accessory is included with the sensor. Seal accessory materials and specifications are: O-ring (nitrile, durometer 90, temperature range -30°C to 125°C), bonded washer (steel outer
ring with nitrile inner ring, temperature range -30°C to 125°C), elastomeric seal (nitrile, temperature range -30°C to 125°C).
6
When using the bonded washer accessory supplied by Honeywell, the customer’s female port connection design should follow DIN 3852-1: 2000-11 size large. If compliance to
DIN 3852-1:2014-05 is required, contact Honeywell for alternate options.
[align=left][color=rgb(0,0,0)]Inductors are commonly used components in switching power supplies. Since their current and voltage phases are different, theoretically, the loss is zero. Inductors are o...
[font=微软雅黑, "][size=14px]The purpose of this article is not to teach you how to adjust it directly, but to tell you why it makes sense to do so, and to tell you why the quadcopter that "only" uses PID...
[i=s]This post was last edited by eagler8 on 2022-6-19 15:48[/i]6. Basic GPIO UsageThe pin operation of the row and blank board is the same as the general syntax of pinpong.[Hua Diao Experience] 01 Ge...
I have fixed the problem in the program, but there are still errors. What's going on? Please give me some advice. Modified: The red code in the following program changed [color=#ff00]INT_GPIOD[/color]...
I need to use some NP0 capacitors now, but I don't have much in stock. I want to buy the kind in packs of 100 on Taobao, but I'm afraid the ones I buy may not be NP0. What should I do? Is it possible ...
In
circuit design,
current
measurement
is widely used, and the main fields are divided into three categories: in measurement,
the electric meter
is used to measure the curre...[Details]
Google's driverless technology is not only an eye-catching technology, but also a subversion of the car usage model.
Those who have watched anti-terrorism films and TV dramas must have been im...[Details]
1. Introduction
Since the 1980s, with the continuous development of automotive electronic technology, there are more and more electronic control units in automobiles, such as electronic fuel i...[Details]
Overview
As a remote network communication control method with advanced technology, high reliability, complete functions and reasonable cost, CAN-bus has been widely used in various automa...[Details]
Product series: PB-B-RS232/485 interface (hereinafter sometimes referred to as "interface") is a product in the PROFIBUS bus bridge series.
The main purpose of the bridge series ...[Details]
On the afternoon of July 10, Beijing time, Taiwan's largest chip designer MediaTek expects its smartphone chip shipments to grow by double digits in the third quarter of this year, and the company is ...[Details]
In today's body control module (BCM) designs, savvy engineers are moving away from electromechanical relays whenever possible. Their next step is to eliminate fuses. But is eliminating fuses a nece...[Details]
This article will introduce a design method for a distributed control system used in a tracking car, which can perform distributed control of motor modules, sensor modules, and lighting control mod...[Details]
0 Introduction
There are many types of sensors, and the working principles, measurement targets and measurement environments of different types of sensors vary greatly. The corresponding detection s...[Details]
Fruit planting is an important part of China's agricultural development, and fruit tree pest control operations are becoming more and more important. At present, the overall level of pesticide applica...[Details]
The demand for improved healthcare environments is endless, so medical imaging equipment with higher resolution is needed to better observe the human body. High resolution brings problems with sign...[Details]
Battery clamps, commonly known as battery connectors, come in two sizes depending on the thickness of the battery terminals. One is the battery clamp used on thick terminals, with a positive termin...[Details]
Electrostatic coupling and interference occur when a charged object is close to the input of the circuit being measured. At low impedance, the effects of interference are not noticeable because th...[Details]
The power supply is the core component of a computer. Although it is not of high value, all computer components rely on the switching power adapter to provide energy, so the stability of a power su...[Details]
The automotive power electronics market has grown rapidly as comfort and active safety features become more common. As traditional mechanical functions shift to electronic applications, the demand ...[Details]