Angular and Linear Encoder and Position Sensing and Indexing
Flow Meters
Contactless Commutation, Speed Measurement and Angular
Position Sensing/Indexing in Automotive Applications
•
•
•
•
•
•
•
•
•
Notes:
1. No purposely added lead. Fully EU Directive 2002/95/EC (RoHS) & 2011/65/EU (RoHS 2) compliant.
2. See http://www.diodes.com/quality/lead_free.html for more information about Diodes Incorporated’s definitions of Halogen- and Antimony-free, "Green"
and Lead-free.
3. Halogen- and Antimony-free "Green” products are defined as those which contain <900ppm bromine, <900ppm chlorine (<1500ppm total Br + Cl)
Electros Static Discharge Withstand - Human Body Model (HMB)
Electros Static Discharge Withstand - Machine Model (MM)
Electros Static Discharge Withstand - Charged Device Model (CDM)
SIP-3
SC59 and SOT23
Characteristic
Value
32
-32
32
60
-50
Unlimited
550
230
-65 to +165
+150
8
800
2
Unit
V
V
V
mA
mA
PRELIMINARY - CONFIDENTIAL
V
DDR
V
OUT_MAX
I
OUT
I
OUT_R
B
P
D
Ts
T
J
ESD HBM
ESD MM
ESD CDM
Notes:
mW
°C
°C
kV
V
kV
5. Stresses greater than the 'Absolute Maximum Ratings' specified above may cause permanent damage to the device. These are stress ratings only;
functional operation of the device at these or any other conditions exceeding those indicated in this specification is not implied. Device reliability may be
affected by exposure to absolute maximum rating conditions for extended periods of time.
6. The absolute maximum V
DD
of 32V is a transient stress rating and is not meant as a functional operating condition. It is not recommended to
operate the device at the absolute maximum rated conditions for any period of time.
Recommended Operating Conditions
(@T
A
= -40°C to +150°C, unless otherwise specified.)
Symbol
V
DD
T
A
Parameter
Supply Voltage
Operating Temperature Range
Operating
Operating
Conditions
Rating
3.0 to 28
-40 to +150
Unit
V
°C
Electrical Characteristics
Symbol
V
OUT_ON
I
LKG
I
DD
Parameter
Output ON Voltage
Output Leakage Current
(when output is off)
Supply Current
(Notes 7 & 8) (@T
A
= -40°C to +150°C, V
DD
= 3V
to 28V, unless
otherwise specified.)
Conditions
I
OUT
= 20mA, B > B
op
V
OUT
= 28V, B < B
rp
, Output off
Output open, T
A
= +25C
Output open, T
A
= -40 to +150C
V
DD
= -18V, T
A
= +25C
V
DD
= -18V, T
A
= -40 to +150C
V
DD
= -28V, T
A
= +25C
V
DD
= -28V, T
A
= -40 to +150C
V
DD
>= 3V, B > B
op
(Note 7)
V
DD
>= 3V
(Note 9)
Min
-
-
-
-
-
-
-
-
-
-
-
Typ
0.2
<0.1
3
-
0.6
0.6
1.6
1.6
10
800
3.75
Max
0.4
10
3.5
4
-
1,500
-
2,500
-
-
Unit
V
µA
mA
mA
µA
µA
µA
µA
µs
kHz
µs
I
DD_R
Reverse Supply Current
t
P_ON
f
c
t
d
t
r
t
f
I
OCL
V
Z
Notes:
Device Power-On Time (start-up time)
Chopping Frequency
Response Time Delay
(time from magnetic threshold reached
to the start of the output rise or fall)
Output Rising Time
(external pull-up resistor R
L
and load
capacitance dependent)
Output Falling Time
(Internal switch resistance and load
capacitance dependent)
Output Current Limit
Zener Clamp Voltage
R
L
= 1kΩ, C
L
= 20pF
-
0.2
1
µs
R
L
= 1kΩ, C
L
= 20pF
B > B
op
, (Note 10 )
I
DD
= 5mA
-
30
28
0.1
-
-
1
55
-
µs
mA
V
7. When power is initially turned on, V
DD
must be within its correct operating range (3.0V to 28V) to guarantee the output sampling. The output state is valid
after the start-up time of 10us typical
from the operating voltage reaching 3V.
8. Typical values are defined at T
A
= +25C, V
DD
= 12V. Maximum and minimum values over the operating temperature range is not tested in production
but guaranteed by design, process control and characterization.
9. Guaranteed by design, process control and characterization. Not tested in production.