EEWORLDEEWORLDEEWORLD

Part Number

Search

ZWS75AF36/J

Description
Switching Power Supplies 76W 36V 2.1A
CategoryPower/power management   
File Size535KB,2 Pages
ManufacturerTDK-LAMBDA
Environmental Compliance
Download Datasheet Parametric View All

ZWS75AF36/J Overview

Switching Power Supplies 76W 36V 2.1A

ZWS75AF36/J Parametric

Parameter NameAttribute value
Product AttributeAttribute Value
ManufacturerTDK-LAMBDA
Product CategorySwitching Power Supplies
RoHSDetails
Output Voltage-Channel 136 VDC
Number of Outputs1 Output
Output Power76 W
Open Frame/EnclosedOpen Frame
Input Voltage85 VAC to 265 VAC
Output Current-Channel 12.1 A
IndustryCommercial
Length4.6 in
Width2.4 in
Height0.5 in
ApprovalsEN60950-1, UL60950-1
Factory Pack Quantity1
Unit Weight8.818490 oz
ZWS-AF Series
50W to 150W Single Output Low Cost, Worldwide Use
Features
u
Universal Input (85 - 265VAC)
u
Power factor Corrected
u
Input transient protected
u
2 year warranty
u
High quality design
u
Peak Power capability
Key Market Segments & Applications
Specifications
Model
AC Input Voltage range
DC Input Voltage range
Input Current (Typ) (1)
Inrush Current
Power Factor (1)
Maximum Ripple and Noise
Temperature Coefficient
Overcurrent Protection (4)
Hold Up Time (Typ) (1)
Leakage Current
Remote On / Off
Operating Temperature
Storage Temperature
Humidity (non condensing)
Withstand Voltage
Isolation Resistance
Vibration (non operating)
Shock
Safety Agency Approvals
Conducted & Radiated EMI
Immunity
Weight (Typ)
Size (W x H x D)
Warranty
VAC
VDC
A
A
-
mV
-
-
ms
-
-
-
-
-
-
-
-
-
-
-
-
g
mm
yrs
ZWS75AF
ZWS100AF
ZWS150AF
85-265VAC (47-63Hz)
120-370VDC
0.8/0.4
1.2/0.6
1.4/0.7
2.0/1.0
14/28 25°C Ambient, Cold Start
Meets EN61000-3-2 (0.99/0.95)
3.3 & 5V: 120mV; 12 to 24V: 150mV; 36 & 48V: 200mV
<0.02%/°C
>105% of Peak Current Capability
20ms
0.5mA max 0.1mA (Typ) at 100VAC 0.16mA (Typ) at 230VAC
See installation manual (Not available with /A cover option)
Convection cooling - See table on page 2
0.7m/s air -10°C to +70°C, derate linearly to 70% load from 60°C to 70°C (2)
-30° to +85°C
Operating: 30 - 90% RH, storage 10-95% RH
I/P~Grnd 2kVAC (20mA), I/P~O/P 3kVAC (20mA), O/P~Grnd 500VAC (100mA) for 1 min.
>100M at 25C & 70%RH, Output to Ground 500VDC
10 - 55Hz (1 minute sweep), 19.6m/s
2
constant X, Y, Z 1 hour
< 196.1 m/s
2
UL60950-1, CSA60950-1, EN60950-1, EN50178, CE Mark
designed to meet EN55011, EN55022-B, FCC Class B, VCCI-B
designed to meet EN61000-4-2,-3,-4,-5,-6,-8,-11
210
290
380
500
55 x 26 x 195
55 x 32 x 222
62 x 35 x 222
75 x 40 x 222
Two Years
ZWS50AF
Notes:
(1) 100/200VAC
(2) ZWS150AF -10 to 60°C, derate linearly to 70% load from 50°C to 60°C
(3) The peak current draw must not exceed a 10 second duration with a duty cycle of 35%
(4) Constant current limit with automatic recovery. Do not operate in a over-load or shorted output condition for more than 30 seconds.
(5) An overvoltage condition on the output will shut down the power supply. The power supply must be re-set by cycling the AC input.
For New Designs, See ZWSBAF Series
1-800-526-2324 • www.us.tdk-lambda.com/lp/
1
Disclaimer: us.tdk-lambda.com/lp/legal.htm
Wearable intelligent safety reminder for motor vehicle drivers based on SensorTag
Wearable intelligent safety reminder for motor vehicle drivers based on SensorTag...
xscc Wireless Connectivity
USB driver question
The book says that the USB master end is called Host and the slave end is called Function, so the corresponding drivers are called USB Host Driver and USB Function Driver respectively. If my current W...
1204 Embedded System
Looking for a high temperature resistant distance sensor, the measured object is 250℃, and the accuracy is 0.1mm
I'd like to ask all the experts in sensors, are there any high-temperature resistant and high-precision distance sensors on the market? The temperature of the measured object is 250℃, and the accuracy...
fbifbi1234567 Sensor
Urgent
Dear brothers and sisters, who has the design of FM receiver? The frequency range of radio waves that the receiver can receive is called the working frequency range or band coverage of the receiver. K...
a381293244 Analog electronics
Common-mode and differential-mode signals and filters
Common-mode and differential-mode signals and filtersWith the development and application of microelectronics technology, electromagnetic compatibility has become an important topic for studying the s...
zbz0529 Analog electronics
DS18B20 temperature value processing VHDL program ask
[table=98%] [tr][td][float=right] [/float] Dear experts, I don't understand why the DS18B20 temperature value is divided by 1600 in the VHDL program that processes the BCD number. Why not divide by 10...
日出东方 FPGA/CPLD

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1670  2399  1443  1470  2705  34  49  30  55  40 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号