THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT
ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT
www.vishay.com/doc?91000
80D
www.vishay.com
Vishay Sprague
NOMINAL CASE SIZE
DxL
1.18 x 1.38 (30.0 x 35.0)
1.38 x 1.38 (35.0 x 35.0)
1.18 x 1.97 (30.0 x 50.0)
1.38 x 1.97 (35.0 x 50.0)
0.984 x 1.57 (25.0 x 40.0)
1.18 x 1.18 (30.0 x 30.0)
1.18 x 1.57 (30.0 x 40.0)
1.18 x 1.97 (30.0 x 50.0)
0.984 x 1.18 (25.0 x 30.0)
1.18 x 1.18 (30.0 x 30.0)
1.38 x 1.18 (35.0 x 30.0)
1.18 x 1.97 (30.0 x 50.0)
1.38 x 1.97 (35.0 x 50.0)
0.984 x 1.18 (25.0 x 30.0)
1.18 x 1.18 (30.0 x 30.0)
0.984 x 1.97 (25.0 x 50.0)
1.18 x 1.97 (30.0 x 50.0)
1.38 x 1.97 (35.0 x 50.0)
0.984 x 0.984 (25.0 x 25.0)
1.18 x 0.984 (30.0 x 25.0)
1.18 x 1.38 (30.0 x 35.0)
1.18 x 1.57 (30.0 x 40.0)
1.18 x 1.57 (30.0 x 40.0)
1.38 x 1.97 (35.0 x 50.0)
1.38 x 1.97 (35.0 x 50.0)
1.38 x 1.97 (35.0 x 50.0)
0.984 x 0.984 (25.0 x 25.0)
0.984 x 1.18 (25.0 x 30.0)
0.984 x 1.57 (25.0 x 40.0)
0.984 x 1.97 (25.0 x 50.0)
1.18 x 1.97 (30.0 x 50.0)
1.38 x 1.97 (35.0 x 50.0)
MAX. ESR (m)
MAX. RIPPLE AT +85 °C (A)
10 kHz TO 40 kHz
4.2
7.2
7.2
10.0
4.9
3.6
4.9
6.1
3.8
3.9
6.6
6.4
10.0
3.5
3.7
5.9
6.2
6.2
3.2
3.6
4.9
5.7
4.7
7.4
6.6
6.6
3.2
3.8
5.2
6.3
7.0
7.4
ELECTRICAL DATA AND ORDERING INFORMATION
CAPACITANCE (μF)
PART NUMBER
120 Hz 10 kHz TO 40 kHz 120 Hz
60.0
33.0
33.0
20.0
57.0
79.0
51.0
40.0
82.0
72.0
40.0
36.0
21.0
139.0
111.0
68.0
55.0
50.0
660.0
460.0
278.0
220.0
248.0
130.0
144.0
141.0
720.0
541.0
343.0
263.0
185.0
191.0
51.0
27.0
27.0
17.0
42.0
63.0
41.0
32.0
55.0
54.0
28.0
28.0
15.0
85.0
74.0
42.0
37.0
37.0
375.0
272.0
165.0
131.0
127.0
82.0
81.0
75.0
377.0
284.0
182.0
140.0
101.0
81.0
3.8
6.2
6.2
8.8
3.9
3.1
4.3
5.3
2.8
3.2
5.0
5.4
8.3
2.2
2.7
3.9
4.7
5.2
1.3
1.7
2.4
2.8
2.1
4.3
3.4
3.4
1.1
1.4
2.0
2.5
3.2
4.0
35 WV
DC
AT +85 °C, SURGE = 44 V
6800.0
10 000.0
12 000.0
15 000.0
3300.0
3300.0
4700.0
6800.0
1500.0
2200.0
3300.0
4700.0
6800.0
680.0
1000.0
1500.0
2200.0
3300.0
150.0
220.0
330.0
470.0
680.0
820.0
1000.0
1200.0
100.0
150.0
220.0
330.0
470.0
680.0
Statements about product lifetime are based on calculations and internal testing. They should only be interpreted as estimations. Also due to external factors, the
lifetime in the field application may deviate from the calculated lifetime. In general, nothing stated herein shall be construed as a guarantee of durability.
80D682P035KC2DE3
80D103P035MC2DE3
80D123P035KE2DE3
80D153P035ME2DE3
80D332P050JD2DE3
80D332P050KB2DE3
80D472P050KD2DE3
80D682P050KE2DE3
80D152P063JB2DE3
80D222P063KB2DE3
80D332P063MB2DE3
80D472P063KE2DE3
80D682P063ME2DE3
80D681P100JB2DE3
80D102P100KB2DE3
80D152P100JE2DE3
80D222P100KE2DE3
80D332P100ME2DE3
80D151P200JA2DE3
80D221P200KA2DE3
80D331P200KC2DE3
80D471P200KD2DE3
80D681P200KD2DE3
80D821P200ME2DE3
80D102P200ME2DE3
80D122P200ME2DE3
80D101P250JA2DE3
80D151P250JB2DE3
80D221P250JD2DE3
80D331P250JE2DE3
80D471P250KE2DE3
80D681P250ME2DE3
50 WV
DC
AT +85 °C, SURGE = 63 V
63 WV
DC
AT +85 °C, SURGE = 79 V
100 WV
DC
AT +85 °C, SURGE = 125 V
200 WV
DC
AT +85 °C, SURGE = 250 V
250 WV
DC
AT +85 °C, SURGE = 300 V
Revision: 20-Jul-16
Document Number: 42060
3
For technical questions, contact:
aluminumcaps4@vishay.com
THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT
ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT
www.vishay.com/doc?91000
Legal Disclaimer Notice
www.vishay.com
Vishay
Disclaimer
ALL PRODUCT, PRODUCT SPECIFICATIONS AND DATA ARE SUBJECT TO CHANGE WITHOUT NOTICE TO IMPROVE
RELIABILITY, FUNCTION OR DESIGN OR OTHERWISE.
Vishay Intertechnology, Inc., its affiliates, agents, and employees, and all persons acting on its or their behalf (collectively,
“Vishay”), disclaim any and all liability for any errors, inaccuracies or incompleteness contained in any datasheet or in any other
disclosure relating to any product.
Vishay makes no warranty, representation or guarantee regarding the suitability of the products for any particular purpose or
the continuing production of any product. To the maximum extent permitted by applicable law, Vishay disclaims (i) any and all
liability arising out of the application or use of any product, (ii) any and all liability, including without limitation special,
consequential or incidental damages, and (iii) any and all implied warranties, including warranties of fitness for particular
purpose, non-infringement and merchantability.
Statements regarding the suitability of products for certain types of applications are based on Vishay’s knowledge of
typical requirements that are often placed on Vishay products in generic applications. Such statements are not binding
statements about the suitability of products for a particular application. It is the customer’s responsibility to validate that a
particular product with the properties described in the product specification is suitable for use in a particular application.
Parameters provided in datasheets and / or specifications may vary in different applications and performance may vary over
time. All operating parameters, including typical parameters, must be validated for each customer application by the customer’s
technical experts. Product specifications do not expand or otherwise modify Vishay’s terms and conditions of purchase,
including but not limited to the warranty expressed therein.
Except as expressly indicated in writing, Vishay products are not designed for use in medical, life-saving, or life-sustaining
applications or for any other application in which the failure of the Vishay product could result in personal injury or death.
Customers using or selling Vishay products not expressly indicated for use in such applications do so at their own risk.
Please contact authorized Vishay personnel to obtain written terms and conditions regarding products designed for
such applications.
No license, express or implied, by estoppel or otherwise, to any intellectual property rights is granted by this document
or by any conduct of Vishay. Product names and markings noted herein may be trademarks of their respective owners.
[size=4]Q: I want to know how to load the 8 cores' .ou files into each core when C6678 is powered on? [/size] [size=4]A: When booting, core0 is the master core by default, and the rest are slave cores...
After 2 days, the problem is still not solved. Please help me!To use custom HID for data transmission, I downloaded the latest USB development routine um0424 from ST website (every failure makes you w...
EtherCAT (Ethernet for Control Automation Technology) is a real-time industrial fieldbus communication protocol based on an Ethernet-based development framework. EtherCAT is one of the fastest indu...[Details]
Reflow soldering, a common soldering method in modern electronics manufacturing, primarily melts solder paste and pads to form solder joints. With technological advancements, soldering equipment ha...[Details]
To understand why car engines need gearboxes, we must first understand the characteristics of different types of engines. An engine refers to a machine that can convert a form of energy into kineti...[Details]
Capable of providing precise and efficient thermal management for artificial intelligence computing power, intelligent sensing and autonomous driving systems
Shenzhen, ...[Details]
1. Introduction
Electronic scales are gradually replacing traditional measuring tools like springs and balances in everyday life, such as electronic price computing scales and electronic weigh...[Details]
On August 18th, Galaxis, a specialist in integrated intelligent intralogistics robotics, officially unveiled its next-generation, ultra-narrow aisle forklift mobile robot, the "VFR Ultra-Narrow Ser...[Details]
Overview
As handheld voice communication devices become more and more popular, they are increasingly used in noisy environments, such as airports, busy roads, crowded bars, etc. In such noisy ...[Details]
A half-bridge is an inverter topology for converting DC to AC. A typical half-bridge circuit consists of two controller switches, a three-wire DC power supply, two feedback diodes, and two capacito...[Details]
With the continuous development of the industrial automation industry, we are seeing an increasing number of intelligent devices using flexible, efficient, and precise robotic arms to p...[Details]
According to Nikkei, Japan has performed poorly in responding to China's power semiconductor challenges.
There are five major companies in Japan's power chip market: Mitsubishi Electric,...[Details]
Intel®
Xeon®
6
-
core processors now support the new Amazon EC2 R8i and R8i-flex instances on Amazon Web Services (AWS).
These new instances offer superior performance and fast...[Details]
1. Introduction
In 2015, Apple's new MacBook and Apple Watch both featured force-sensing technology, which Apple calls Force Touch. Each time a user presses the touchpad, the device not only p...[Details]
On August 20, Huawei Device announced that the all-new M7 is the first to feature an in-cabin laser vision solution. This solution offers enhanced active safety capabilities compared to primary vis...[Details]
Compiled from semiengineering
The industry is increasingly concerned about power consumption in AI, but there are no simple solutions. This requires a deep understanding of software and ...[Details]
introduction
The widespread use of air conditioner communication circuits began with the rise of household inverter air conditioners. With China's energy conservation and emission reduction in...[Details]