IP Rating ............................................................ IP 40 .....................................................................IP 40
*RoHS Directive 2002/95/EC Jan. 27, 2003 including annex and RoHS Recast 2011/65/EU June 8, 2011.
Specifications are subject to change without notice.
The device characteristics and parameters in this data sheet can and do vary in different applications and actual device performance may vary over time.
Users should verify actual device performance in their specific applications.
Model 91, 92, 93, 94 & 95 - 5/8 ” Square Single-Turn Panel Control
Mechanical Characteristics
1
Stop Strength (1/4 ” D shaft) .............................................................................................................................................45.19 N-cm (4 lb.-in.)
(1/8 ” D shaft) .............................................................................................................................................33.89 N-cm (3 lb.-in.)
Starting ........................................................................................................................................... 0.3 max. above average running torque
Running Torque
Single or Dual Section (A & R Bushings) ....................................................................................... 0.21 to 1.06 N-cm (0.3 to 1.5 oz.-in.)
Single or Dual Section (C & U Bushings) ....................................................................................... 0.14 to 1.06 N-cm (0.2 to 1.5 oz.-in.)
Mounting .............................................................................................................................................1.7-2.0 N-m (15-18 lb.-in.) maximum
Variation ...................................................................................................................... 0.35 N-cm (0.5 oz.-in.) maximum in 45 ° shaft travel
Weight (Single Section, Metal Bushing)...............................................................................................................................12.7 grams nominal
Terminals .................................................................................................................................Printed circuit terminals, J-Hooks or solder lugs
Soldering Condition ...........................................Recommended hand soldering using Sn95/Ag5 no clean solder, 0.025 ” wire diameter.
Maximum temperature 399 °C (750 °F) for 3 seconds. No wash process to be used with no clean flux.
Marking ..................................................................................Manufacturer’s trademark, date code, resistance, manufacturer’s part number
Ganging (Multiple Section Potentiometers).............................................................................................................................2 cups maximum
Hardware ...................One lockwasher and one mounting nut is shipped with each potentiometer, except where noted in the part number.
NOTE:
1
At
room ambient: +25 °C nominal and 50 % relative humidity nominal, except as noted.
Performance specifications do not apply to units subjected to printed circuit board cleaning procedures.
Specifications are subject to change without notice.
The device characteristics and parameters in this data sheet can and do vary in different applications and actual device performance may vary over time.
Users should verify actual device performance in their specific applications.
Model 91, 92, 93, 94 & 95 - 5/8 ” Square Single-Turn Panel Control
Specifications are subject to change without notice.
The device characteristics and parameters in this data sheet can and do vary in different applications and actual device performance may vary over time.
Users should verify actual device performance in their specific applications.
3
2
Model 91, 92, 93, 94 & 95 - 5/8 ” Square Single-Turn Panel Control
Product Dimensions
Plastic
Shaft
Styles
SHAFT TYPE "B"
(USES BUSHING A)
1.60+.38/-.00
(.063+.015/-.000)
6.32+.000/-.152
(.249+.000/.006)
DIA.
22.23
(.875)
SHAFT TYPE "D"
(USES BUSHING C)
3.16+.00/-.15
DIA.
(.1245+.000/-.006)
SHAFT TYPE "T"
(USES BUSHING U)
1.50 ± .25
(0.06 ± .001)
.79
(0.03)
STD. LENGTHS:
16.0
(.630)
22.0
(.866)
1.19
(.047)
STD. LENGTHS:
15.88
19.05
(.625) (.750)
12.70
(.500)
STD. LENGTHS:
12.70
15.88
19.05
(.500) (.625) (.750)
3.988 +0.000/-0.051
(.157 +.000/-.002)
DIA.
SHAFT TYPE "C"
(USES BUSHING A)
11.18 ± .38
(.440 ± .015)
SHAFT TYPE "R"
(USES BUSHING R)
1.80 ± .25
(0.07 ± .001)
5.994 +0.000/-0.051
(.236 +.000/-.002)
DIA.
1.00
(.04)
STD. LENGTHS:
16.0
(.630)
22.0
(.866)
SHAFT TYPE "W"
(USES BUSHING A)
14.27 ± .25
(.562 ± .010)
6.31+.025/-.051
(.2485+.001/.002)
DIA.
STD. LENGTHS:
25.40
(1.00)
5.49
(.216)
STD. LENGTHS:
19.05
22.23
(.750) (.875)
6.30+.000/-.152
(.248+.000/.006)
DIA.
48 TOOTH
Metal
Shaft
Styles
SHAFT TYPE "A"
(USES BUSHING A)
6.32+.010/-.025
(.2490+.0004/.0010)
DIA
SHAFT TYPE "H"
(USES BUSHING A)
“F” ± .38
(“F” ± .015)
6.32+.010/-.025
(.2490+.0004/.0010)
DIA
5.486 ± .051
(.216 ± .002)
25.4
(1.000)
SHAFT TYPE "S"
(USES BUSHING R)
“F” ± .381
(“F” ± .015)
6.000+.000/-.035
(.2362+.0000/.0014)
DIA
3.988 ± .076
(.157 ± .003)
STD. LENGTHS:
16.0
(.630)
22.0
(.866)
STD. LENGTHS:
12.70
(.500)
15.88
(.625)
19.05
(.750)
22.23
(.875)
STD. LENGTHS:
19.05
(.750)
7.95
(.313)
22.23
(.875)
11.13
(.438)
FLAT LENGTH “F”:
FLAT LENGTH “F”:
6.99
(.275)
12.98
(.511)
SHAFT TYPE "E"
(USES BUSHING C)
0.79 ± 0.25
(.031 ± .010)
0.79
(.031)
STD. LENGTHS:
12.0
(.500)
16.0
(.625)
19.0
(.750)
3.16
(.1245)
DIA
SHAFT TYPE "J"
(USES BUSHING R)
1.80 ± 0.25
(.071 ± .010)
6.00+.000/-.035
(.2362+.0000/.0010)
DIA
SHAFT TYPE "V"
(USES BUSHING U)
1.50 ± 0.25
(.059 ± .010)
0.79 ± 0.13
(.031 ± .054)
STD. LENGTHS:
16.0
(.630)
22.0
(.866)
3.99+.000/-.035
(.1571+.0000/.0010)
DIA
1.00 ± 0.13
(.039 ± .054)
STD. LENGTHS:
SHAFT TYPE "G"
(USES BUSHING A)
1.60+.38/-.00
(.063+.015/-.000)
6.32+.010/-.025
(.2490+.0004/.0010)
DIA.
1.194
(.047)
12.70
(.500)
STD. LENGTHS:
15.88
19.05
(.625) (.750)
22.23
(.875)
16.0
(.630)
22.0
(.866)
TOLERANCES EXCEPT AS SHOWN: .XX = ±
.02
(.050)
.005
.XXX = ±
(.127)
.0005
.XXXX = ±
(.0127)
MM
DIMENSIONS:
(INCHES)
Specifications are subject to change without notice.
The device characteristics and parameters in this data sheet can and do vary in different applications and actual device performance may vary over time.
Users should verify actual device performance in their specific applications.
How to Order Model 91, 92, 93, 94 & 95 Panel Controls
91
A
2
A
-
A
28
-
A
15
/
A1 5
L
Part number for multiple section potentiometers must have
a taper and resistance value for each section.
A
D
ANTI-ROTATION LUG
Single .305 ” (7.8 mm) R,
90 °CW
No Lug
# SECTIONS
1 Single
2 Dual
BUSHING
Metal Plain 3/8 ” (9.53 mm) D x 3/8 ” (9.53 mm) L
Metal Plain 1/4 ” (6.35 mm) D x 1/4 ” (6.35 mm) L
Metal Plain 10 mm D x 9 mm L
Metal Plain 7 mm D x 9 mm L
SHAFT
LENGTH
(FMS)
Code Description
16
1/2 ”L
20
5/8 ”L
24
3/4 ”L
28
7/8 ”L
32
1 ”L
16
22
16 mmL
22 mmL
METRIC
AVAILABLE
ONLY IN
BUSHING
Code
A, C
A, C
A, C
A
A
R, U
R, U
ELEMENT TAPER
TYPE/TOLERANCE
(A)
Linear Cermet ±10 %
(H)
Linear Cermet ±5 %
RoHS IDENTIFIER
L
Compliant
A
C
R
U
91
92
93
94
95
MODEL
Single-Turn, In-Line PC Pins
Single-Turn, In-Line J-Hooks
Single-Turn, L-Pattern PC Pins
Single-Turn, L-Pattern J-Hooks
Single-Turn, Triangle-Pattern Solder Lugs
AVAILABLE ONLY IN
LENGTHS
BUSHINGS
(CODE)
(CODE)
16, 20, 24, 28
A
24, 28
A
16, 20, 24
C
Metric 16, 22
R
Metric 16, 22
U
32
A
16, 20, 24
A
16, 20, 24
C
16, 20, 24, 28
A
24, 28
A
Metric 16, 22
R
Metric 16, 22
R
Metric 16, 22
U
(B)
(E)
Linear C-P ±20 %
Linear C-P ±10 %
SHAFT TYPE
B
C
D
R
T
W
A
E
G
H
J
S
V
Plastic Single Slotted 1/4 " (6.35 mm) D
Plastic Single Flatted 1/4" (6.35 mm) D
Plastic Single Plain 1/8" (3.18 mm) D
Plastic Single Slotted 6 mm D
Plastic Single Slotted 4 mm D
Plastic Single Knurled 1/4" (6.35 mm) D
Metal Single Plain 1/4" (6.35 mm) D
Metal Single Slotted 1/8" (3.18 mm) D
Metal Single Slotted 1/4" (6.35 mm) D
Metal Single Flatted 1/4" (6.35 mm) D
Metal Single Slotted 6 mm D
Metal Single Flatted 6 mm D
Metal Single Slotted 4 mm D
(C)
(D)
(F)
(G)
(S)
(T)
CW Audio Cermet ±10 %
CW Audio C-P ±20 %
CCW Audio Cermet ±10 %
CCW Audio C-P ±20 %
CW Audio C-P ±10 %
CCW Audio C-P ± 10 %
RESISTANCE CODE
VALUE IN OHMS
(05) - 100
(30) - 15 K
(28) - 150
(16) - 20 K
(06) - 200
(17) - 25 K
(07) - 250
(18) - 50 K
(08) - 500
(20) - 100 K
(10) - 1 K
(21) - 200 K
(11) - 2 K
(22) - 250 K
(12) - 2.5 K (23) - 500 K
(13) - 5 K
(25) - 1 M
(15) - 10 K
(10) - 1 K
(18) - 50 K
(12) - 2.5 K
(20) - 100 K
(13) - 5 K
(22) - 250 K
(15) - 10 K
(23) - 500 K
(16) - 20 K (25) - 1 M
(17) - 25 K
(10) - 1 K
(18) - 50 K
(12) - 2.5 K (20) - 100 K
(13) - 5 K
(22) - 250 K
(15) - 10 K (23) - 500 K
(17) - 25 K (25) - 1 M
Boldface features are Bourns standard options.
All others are available with higher minimum order
quantities.
REV. 04/18
Specifications are subject to change without notice.
The device characteristics and parameters in this data sheet can and do vary in different applications and actual device performance may vary over time.
Users should verify actual device performance in their specific applications.
Design of wireless signal transmission system I. Task Design and manufacture a mixed signal wireless transmission device. The device consists of a transmitter and a receiver, and its block diagram is ...
I want to use the following program to generate a PWM wave in T3PWM, why doesn't it work?#include \"f2407_c.h\"#define pwm3_duty 1000// Shield interrupt programvoid inline disable(){asm(\" setc INTM\"...
We are working on a grid-connected inverter project. There is a problem of phase-locking when the output current tracks the grid voltage. Usually, because the grid voltage waveform is not very clean, ...
How can EEWORLD stand out from the numerous technical forums? This is the common wish of everyone who enters the forum. It is true that there are many technical forums, each with its own technical foc...
On August 23rd, Geely's subsidiary, Jiyao Tongxing, announced it has the industry's largest advanced production capacity for tandao
batteries
, with eight production bases across China. Jiy...[Details]
The problem of dynamic sealing of equipment always exists with the operation of the equipment. Today, we have specially sorted out the various commonly used sealing forms, usage scope and character...[Details]
Flip-chip and ball grid array (BGA) are two widely used packaging technologies in the electronics industry. Each has its own advantages and limitations, and in some cases, they can complement each ...[Details]
A line scan lens is an industrial lens used with line scan cameras. Its imaging principle is to capture the image of the workpiece using a linear sensor and then perform digital signal processing t...[Details]
When you are happily watching NBA or football, your wife asks you to turn off the lights in the bedroom. Would you be depressed? Of course, unless you are not afraid of your wife.
Now you are ...[Details]
According to foreign media reports, BMW has just been granted a patent for a screen that could cover the entire roof. BMW hopes to transform at least a portion of the vehicle's headliner into a dis...[Details]
UPS stands for Uninterruptible Power Supply, which includes energy storage devices. It is mainly used to provide uninterruptible power supply for devices that require high power stability.
...[Details]
Tires are a very important component for cars. They are related to the driving experience of the vehicle. We are almost inseparable from cars in our daily lives. For tires, according to the role of...[Details]
Civilian internal combustion engines operate in the range of approximately 1000-4000 rpm. This results in the engine's kinetic energy being ineffective at low or high rpm, making starting difficult...[Details]
The fracture mechanism is stress concentration, which typically occurs at the capacitor lead pins or pad connection points, as shown in the figure. Under vibration, the capacitor lead pins and pad ...[Details]
Batteries are a core component of new energy vehicles, accounting for over 40% of the total cost. This is also the area where automakers are most willing to tamper with costs. Since 2021, domestic ...[Details]
For the average person, an electricity meter is a monthly bill. For beginners, it's a collection of components and parts. For experienced meter engineers, however, it's a complex and complex proces...[Details]
The power transmission system between a car's engine and drive wheels is called its drivetrain. It ensures the necessary traction and speed under various driving conditions, and coordinates these t...[Details]
In a previous article, we introduced
the origin of
AVTP
and the meaning of the various header fields when using it to transmit audio. This article will explain the meaning and constraints of...[Details]
Servo motors, also known as actuator motors, serve as actuators in automatic control systems, converting received electrical signals into angular displacement or angular velocity output on the moto...[Details]