Data Sheet
60 Amp High Voltage
SCHOTTKY BARRIER
RECTIFIERS
Mechanical Dimensions
.900
.200
2 plcs.
.75
.670
FBR6030 . . . 6060 Series
Description
JEDEC
T0-3P
.050 Typ
.175
.200
Features
n
HIGH CURRENT CAPABILITY
WITH LOW V
F
n
HIGH EFFICIENCY w/LOW POWER LOSS
n
HIGH SURGE VOLTAGE AND
TRANSIENT PROTECTION
n
MEETS UL SPECIFICATION 94V-0
Electrical Characteristics @ 25
o
C.
Maximum Ratings
Peak Repetitive Reverse Voltage...V
RRM
Working Peak Reverse Voltage...V
RWM
DC Blocking Voltage...V
DC
RMS Reverse Voltage...V
R
(rms)
Average Forward Rectified Current...I
O
@ T
C
= 110°C V
R
(equiv.) < = 0.2V
R(DC)
Non-Repetitive Peak Forward Surge Current...I
FSM
@ Rated Load Conditions, ½ Sine Wave, Single Phase, 60HZ
Forward Voltage...V
F
@ I
F
= 30 Amps
DC Reverse Current...I
R
@ Rated DC Blocking Voltage
T
C
= 25°C
T
C
=125°C
FBR6030 . . . 6060 Series
FBR6030 FBR6035 FBR6040 FBR6045 FBR6050 FBR6060
30
30
30
21
35
35
35
24
40
40
40
28
45
45
45
31
50
50
50
35
60
60
60
42
Units
Volts
Volts
Volts
Volts
Amps
Amps
Volts
............................................. 6 0 ...............................................
............................................. 6 0 0 ...............................................
< ........................ .65 ........................ >
< ........ .75 ......... >
............................................. 1 0 ............................................... mAmps
< ........................ 1 0 0 ........................ >
< .......... 1 5 0 ........ > mAmps
............................................. -65 to 150 ......................................
°C
Operating & Storage Temperature Range...T
J,
T
STRG
Page 7-44
Data Sheet
60 Amp High Voltage
SCHOTTKY BARRIER
RECTIFIERS
Typical Reverse Characteristics
Reverse Current (mA)
Forward Current Derating Curve
FBR6050...6060
FBR6030...6045
FBR6030...6045
Case Temperature (
o
C)
Typical Junction Capacitance
Reverse Voltage (Volts)
Typical Reverse Characteristics
Reverse Voltage (Volts)
Typical Forward Characteristics
FBR6050...6060
Reverse Current (mA)
FBR6050...6060
pF
Reverse Voltage (Volts)
Common Cathode,
Suffix "C"
Peak Forward Surge Current
Amps
FBR6030...6045
3
Amps
1
2
Case
Ratings at
25 Deg. C ambient
temperature
unless otherwise
specified.
Single Phase Half
Wave, 60 HZ
Resistive or
Inductive Load.
Forward Voltage (Volts)
NOTES:
1. Measured @ 1 MHZ and applied reverse voltage of 4.0V.
2. Thermal Resistance Junction to Case, Jedec Method.
3. When Mounted to heat sink, from body.
Number of Cycles @ 60 Hz
For Capacitive
Load, Derate
Current by 20%.
Page 7-45
FBR6030 . . . 6060 Series
Amps